User’s Information Manual for the Operation and

Maintenance of Heat Recovery Ventilators

Fig. 1 — Controls

A94244

OPERATING YOUR HEAT RECOVERY VENTILATOR (HRV)

Your HRV is designed to operate as an integral part of your total heating and cooling system. With the exception of high capacity
models, which are available with standard controls only, all HRVs offer 3 control options (See Fig. 1.):

• Basic Controls: Allow the user to manually set the unit to low- or high-fan speed as required to maximize comfort. Controls may
be unit mounted.

• Standard Controls: Offer automatic dehumidistat control and the option to select low speed or intermittent fan during heating season.

• Automatic Controls: In addition to the operational features found with standard controls, automatic controls feature a recircula-
tion mode. Not for use with forced-air HVAC systems.

Fan Speed Control

—Enables user to modulate fan speed from low to high.

Dehumidistat Control

—Allows the user to select the relative humidity level at which the unit would change fan speed to avoid

condensation problems while heating during the winter months.

TABLE 1 — HUMIDITY SETTINGS

Continuous Mode

—If the relative humidity inside the building is lower than selected, air exchange would occur with the outside

at low speed. If the relative humidity level inside the building is higher than selected, air exchange would occur outside at high
speed. This ensures continuous air exchange for constant air quality.

Intermittent Mode

—If the relative humidity inside the building is lower than selected, no air exchange would occur, and the sys-

tem would turn off. If the relative humidity inside the building is higher than selected, air exchange would occur with outside at
high speed. This ensures minimum air exchange level when the building is unoccupied to minimize operating cost.

Recirculation Mode

—If the relative humidity inside the building is lower than selected, indoor air would be circulated and filtered

at high speed. If the relative humidity inside the house is higher than selected, air exchange would occur with outside at high speed.
This ensures continuous movement and filtration of air for maximum comfort.

OUTSIDE TEMPERATURE

DOUBLE-PANE WINDOWS

TRIPLE-PANE WINDOWS

°C

°F

(PERCENTAGE)

(PERCENTAGE)

10

50

55

65

0

32

45

55

–10

14

35

45

–20

2

4

30

40

–30

–22

25

35

OFF

HIGH

LOW

ARRET

HAUTE

BASSE

% D HUMIDITE RELATIVE HUMIDITY

20

25

30

40

50

60

70

80

OFF

ARRET

LOW

BASSE

INTERMITTENT

AIR EXCHANGE

ECHANGE D´AIR

´

ON

MARCHE

% HUM. RELATIVE HUM.

55%
45%
35%
30%

EXT. TEMP. EXT.

% D´HUMIDITE RELATIVE HUMIDITY

´

% HUM. RELATIVE HUM.

55%
45%
35%
30%

EXT. TEMP. EXT.

MODE

MAINTENANCE

AIR EXCHANGE

ECHANGE D´AIR

´

20

25

30

40

50

60

70

80

10

°

C/50

°

F

0

°

C/32

°

F

–10

°

C/14

°

F

–20

°

C/– 4

°

F

´

´

10

°

C/50

°

F

0

°

C/32

°

F

–10

°

C/14

°

F

–20

°

C/– 4

°

F

Basic Control

Standard Control

Automatic Control

VA3B, VA5B, and VC5B

HEAT RECOVERY VENTILATOR

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Carrier HRVCCSVU

Other Carrier Models