Carrier HRVCCSHB1100 - Manual
Carrier HRVCCSHB1100 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Inspect Equipment; should be located in a conditioned space; COMPONENT DESCRIPTION; ER
- Page 3 – UNIT INSTALLATION; UNIT DAMAGE HAZARD; CAUTION; Mount Unit; CARBON MONOXIDE POISONING HAZARD; WARNING; NOTE
- Page 4 – PROPERTY DAMAGE HAZARD; Insulated flexible duct is required on both fresh--air inlet and; IMPORTANT; WALL CONTROL; Table 1 – Basic Control
- Page 5 – Operation
- Page 6 – BOOT SEQUENCE; ELECTRICAL CONNECTIONS; ELECTRICAL SHOCK / FIRE HAZARD; ACCESSORIES; 0 Minute Timer; 0 Minute Adjustable Timer
- Page 7 – DETAIL A; See Detail A
- Page 8 – VENTILATION EVALUATION; Table 3 – Ventilation Air Requirements, cfm; Table 4 – Ventilation Air Requirements, L/s; FLOOR; CONTROL BOARD OPERATION; UNIT COMPONENT DAMAGE HAZARD
- Page 9 – TROUBLESHOOTING; Override Test
- Page 10 – Table 5 – Troubleshooting; NO C NC I OC OL Y R G B
- Page 11 – HRV DEFROST CYCLES
- Page 12 – CONNECTION DIAGRAM
- Page 13 – LOGIC DIAGRAM
ERVCCSVB1100, ERVCCSHB1100
HRVCCSVB1100, HRVCCSHB1100
Energy / Heat Recovery Ventilator
Installation Instructions
NOTE
: Read the entire instruction manual before starting the
installation.
TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS
1
. . . . . . . . . . . . . . . . . . . . . . . . .
INTRODUCTION
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALLATION CONSIDERATIONS
2
. . . . . . . . . . . . . . . . . . .
COMPONENT DESCRIPTION
2
. . . . . . . . . . . . . . . . . . . . . . . .
UNIT INSTALLATION
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WALL CONTROL
4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPERATING THE ERV/HRV WITH
THE INFINITY CONTROL
6
. . . . . . . . . . . . . . . . . . . . . . . . . . .
ELECTRICAL CONNECTIONS
6
. . . . . . . . . . . . . . . . . . . . . . . .
ACCESSORIES
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BALANCING ERV/HRV
7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VENTILATION EVALUATION
8
. . . . . . . . . . . . . . . . . . . . . . . .
CONTROL BOARD OPERATION
8
. . . . . . . . . . . . . . . . . . . . . .
CARE AND MAINTENANCE
8
. . . . . . . . . . . . . . . . . . . . . . . . .
TROUBLESHOOTING
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1. Fresh air to building port
2. Exhaust air from building port
3. Fresh air from outside port
4. Exhaust air to outside port
A08103
Fig. 1 -- ERV/HRV Unit (Top Port)
A05330
Fig. 2 -- ERV/HRV Unit (Side Port)
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury or property
damage. Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories
when modifying this product. Refer to the individual instructions
packaged with kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing
and work gloves. Have a fire extinguisher available. Read these
instructions thoroughly and follow all warnings or cautions
included in literature and attached to the unit. Consult local
building codes and the current editions of the National Electrical
Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical
Code CSA C22.1.
Recognize safety information. This is the safety--alert symbol
.
When you see this symbol on the unit and in instruction manuals,
be alert to the potential for personal injury.
Understand the signal words
DANGER
,
WARNING
, and
CAUTION
. These words are used with the safety--alert symbol.
DANGER
identifies the most serious hazards which
will
result in
severe personal injury or death.
WARNING
signifies hazards
which
could
result in personal injury or death.
CAUTION
is used
to identify unsafe practices which
may
result in minor personal
injury or product and property damage.
NOTE
is used to highlight
suggestions which will result in enhanced installation, reliability, or
operation.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 INTRODUCTION The Energy/Heat Recovery Ventilator (ERV/HRV) is used toexchange indoor stale air with outside fresh air. The unit is equipped with a special energy/heat recovery core which transfersboth sensible and/or latent heat between the fresh incoming air and stale exhaust air. The cross--flow...
3 UNIT INSTALLATION UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation.Do not install ERV/HRV in a corrosive or contaminated atmosphere. CAUTION ! Mount Unit The ERV/HRV can be suspended from floor joists using chains and 4 springs. Attach metal ha...
4 Connect Ducts to ERV/HRV PROPERTY DAMAGE HAZARD Failure to follow this caution may result in minor property damage from sweating duct or loss of unit efficiency and capacity.If ERV/HRV duct work is installed in an unconditioned space, insulated flexible duct is required. CAUTION ! Insulated flexib...