Carrier GAPAAXCC2025- User Manual

Carrier GAPAAXCC2025

Carrier GAPAAXCC2025– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
Page: / 10

Table of Contents:

  • Page 2 – APPLICATION CONSIDERATIONS; GAP
  • Page 3 – INSTALLATION; CAUTION
  • Page 4 – Top Mount; Side Mount
  • Page 5 – WARNING
  • Page 6 – MAINTENANCE
  • Page 8 – TROUBLESHOOTING
  • Page 9 – SPECIFICATIONS AND DIMENSIONS; Table 1—Specifications and Dimensions
  • Page 10 – WARRANTY; FOR SERVICE OR REPAIR, FOLLOW THESE STEPS IN ORDER:; your builder or home retailer if yours is a new residence.; SECOND; INFINITY; CARRIER WILL NOT BE RESPONSIBLE FOR:; Some
Loading the manual

GAPAA
Infinity

t

Air Purifier

Sizes 1625 and 2025

Installation Instructions

NOTE

: Read the entire instruction manual before starting the

install.

TABLE OF CONTENTS

Page

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

HOW IT WORKS

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . .

APPLICATION CONSIDERATIONS

2

. . . . . . . . . . . . . .

INSTALLATION

3--5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP AND OPERATION

6

. . . . . . . . . . . . . . . . . . .

MAINTENANCE

6--7

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

TROUBLESHOOTING

8

. . . . . . . . . . . . . . . . . . . . . . . . . .

SPECIFICATIONS AND DIMENSIONS

9

. . . . . . . . . . . .

WARRANTY

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

Congratulations for selecting the Infinity

t

Air Purifier for your

home comfort system! The Infinity

t

Air Purifier is proven to

remove and kill airborne germs and allergens, including viruses,
bacteria, and mold spores. The Infinity

t

Air Purifier is a

cornerstone of Carrier’s Healthy Home Solutions for providing
healthier, cleaner air in your home.

HOW IT WORKS

The Infinity

t

Air Purifier provides extremely high filtration

performance while killing captured contaminants, including
viruses, bacteria, and mold spores. The Infinity

t

Air Purifier

treats the entire air--stream through a state of the art, three--stage
process, exclusive to Carrier.

In stage one, the particles are electrically charged by a
precision--point ionization array as they enter the Infinity

t

Air

Purifier.

In stage two, the charged particles are electrically attracted to the
air purification cartridge, which is located within an electric field.

In stage three, captured particles are killed by electrical current
flow and ion bombardment.

The Infinity

t

Air Purifier is CSA certified for shock and

electrical fire hazard only.

La Infinity

t

Air Purifier certification CSA vise uniquement les

risques de choc electrique et.

A05265

Fig. 1

---

GAPAA Unit

SAFETY CONSIDERATIONS

Improper

installation,

adjustment,

alteration,

service,

maintenance, or use can cause explosion, fire, electrical shock or
other conditions which may cause personal injury or property
damage.

Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The qualified
installer or agency must use factory authorized kits or accessories
when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.

Follow all safety codes. Wear safety glasses and work gloves.
Have fire extinguisher available.

Read these instructions

thoroughly and follow all warning or cautions attached to the
unit. Consult local building codes and National Electrical Code
(NEC) for special requirements.

It is important to recognize safety information.

This is the

safety--alert symbol

!

!

. When you see this symbol on the unit

and in instructions or manuals, be alert to the potential for
personal

injury.

Understand

the

signal

words

DANGER,

WARNING, and CAUTION.

These words are used with the

safety--alert symbol.

DANGER identifies the most serious

hazards which

will

result in severe personal injury or death.

WARNING signifies hazards which

could

result in personal

injury or death. CAUTION is used to identify unsafe practices
which

may

result in personal injury or product and property

damage. NOTE is used to highlight suggestions which

will

result

in enhanced installation, reliability, or operation.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - APPLICATION CONSIDERATIONS; GAP

2 APPLICATION CONSIDERATIONS The Infinity t Air Purifier is designed for use in the return air duct of a forced air heating, cooling, and ventilation system.Models GAPAAXCC1625 and GAPAAXCC2025 are specificallydesigned for use in systems with a forced air gas furnace. Air Conditioning The Infinity t...

Page 3 - INSTALLATION; CAUTION

3 INSTALLATION Step 1 — Check Infinity t Air Purifier Components CUT HAZARD Failure to follow this caution may result in personal injury. Sheet metal parts may have sharp edges or burrs. Use careand wear appropriate protective clothing and gloves whenhandling parts. CAUTION ! a. Carefully remove all...

Page 4 - Top Mount; Side Mount

4 Step 3 — Mount Cabinet ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in personalinjury or death. Before installing or servicing system, always turn off mainpower to system. There may be more than 1 disconnectswitch. ! WARNING UNIT DAMAGE HAZARD Failure to fol...

Other Carrier Models