Carrier FE4ANF003000 - Installation Manual
Carrier FE4ANF003000 – Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLATION; Procedure 1 — Check Equipment
- Page 3 – Fig. 1 - Slope Coil Unit in Upflow Application
- Page 6 – PROPERTY DAMAGE HAZARD; CAUTION; NOTE; Procedure 3 — Air Ducts
- Page 7 – Procedure 4 — Electrical Connections; WARNING
- Page 8 – Procedure 5 — Refrigerant Tubing Connection and
- Page 9 – Procedure 6 — Condensate Drain
- Page 10 – Procedure 7 — Unit Start- Up
- Page 11 – H. Ventilation Accessory; Procedure 9 — Start- Up and Troubleshooting; Board Connections
- Page 14 – CARE AND MAINTENANCE
FE4A
FE5A
Installation Instructions
COMMUNICATING FAN COIL
FOR PURON
r
REFRIGERANT
SIZES 002, 003, 004, 005, 006
NOTE
: Read the entire instruction manual before starting the
installation.
PAGE
SAFETY CONSIDERATIONS
1
. . . . . . . . . . . . . . . . . . . . . . . . .
INTRODUCTION
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALLATION
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Check Equipment
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mount Fan Coil
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air Ducts
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Connections
7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Refrigerant Tubing Connection & Evacuation
8
. . . . . . . . . .
Condensate Drain
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unit Start- Up
10
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessory Installation
10
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Start- Up and Troubleshooting
11
. . . . . . . . . . . . . . . . . . . . .
FE4A, FE5A Fan Coil Sequence of Operation
14
. . . . . . . . .
CARE AND MAINTENANCE
14
. . . . . . . . . . . . . . . . . . . . . . . .
PURON
R
REFRIGERANT QUICK REFERENCE GUIDE
16
.
SAFETY CONSIDERATIONS
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury
or death.
Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The
qualified installer or agency must use factory- authorized kits
or accessories when modifying this product. Refer to the
individual instructions packaged with kits or accessories
when installing.
!
WARNING
Follow all safety codes. Wear safety glasses and work gloves. Use
quenching cloth for brazing operations. Have fire extinguisher
available. Read these instructions thoroughly and follow all
warnings or cautions attached to the unit. Consult local building
codes and National Electrical Code (NEC) for special
requirements.
Recognize safety information. This is the safety- alert symbol
.
When you see this symbol on the unit and in instructions manuals,
be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, CAUTION,
and NOTE. These words are used with the safety- alert symbol.
DANGER identifies the most serious hazards which
will
result in
severe personal injury or death. WARNING signifies hazards
which
could
result in personal injury or death. CAUTION is used
to identify unsafe practices which
may
result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which
will
result in enhanced installation, reliability, or
operation.
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury
or death.
Before installing or servicing unit, always turn off all power
to unit. There may be more than 1 disconnect switch. Turn
off accessory heater power if applicable.
!
WARNING
INTRODUCTION
Model FE4A, FE5A fan coils are designed to be installed with a
communicating User Interface. The FE4A, FE5A fan coils will
provide airflow at a rate commanded by the User Interface. The
nominal airflow/ton rate is 350 CFM/ton. The User Interface will
modify the commanded airflow under certain operating modes.
Refer to the User Interface literature for further system control
details. This fan coil will not respond to commands from a
common thermostat except under certain emergency situations
explained in this document. The instructions contained herein
provide guidance to successfully install this fan coil.
Model FE5A fan coil units are designed for upflow or downflow
applications only. Model FE4A fan coil units are designed for
flexibility and can be used for upflow, horizontal, or downflow
applications. These units are designed specifically for Puron
r
(R- 410A) refrigerant and must be used only with Puron
r
refrigerant air conditioners and heat pumps as shipped.
These units are designed to meet cabinet air leakage of less than
2% at 0.5 inches W.C. and cabinet air leakage less than 1.4% at 0.5
inches W.C. when tested in accordance with ASHRAE 193
standard. Because of this, units need special attention in the
condensate pan and drain connection area and when brazing
tubing.
These units are available for application in systems of 18,000
through
60,000
Btuh
nominal
cooling
capacities.
Factory- authorized, field- installed electric heater packages are
available in 5 through 30 kW. See Product Data for available
accessory kits.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 INSTALLATION Procedure 1 — Check Equipment Unpack unit and move to final location. Remove carton taking carenot to damage unit.Inspect equipment for damage prior to installation. File claim with shipping company if shipment is damaged or incomplete. Locateunit rating plate which contains proper in...
3 A COIL UNITS POWER ENTRY OPTIONS LOW VOLT ENTRY OPTIONS FIELD SUPPLIEDRETURN PLENUM UPFLOW/DOWNFLOW SECONDARY DRAIN UPFLOW/DOWNFLOW PRIMARY DRAIN 1 1 ⁄ 2 ″ 2 1 ⁄ 2 ″ 19" (482.6 mm) FIELD SUPPLIED SUPPLY DUCT UPFLOW/DOWNFLOW SECONDARY DRAIN UPFLOW/DOWNFLOW PRIMARY DRAIN 002 - 17.5" (444.5 m...
6 COIL SUPPORT RAIL COIL BRACKET DRAIN PAN SUPPORT BRACKET COIL SUPPORT RAIL COIL BRACKET HORIZONTAL DRAIN PAN PRIMARY DRAIN HORIZONTAL RIGHT SECONDARY DRAIN HORIZONTAL RIGHT REFRIGERANT CONNECTIONS AIR SEAL ASSEMBLY A B C HORIZONTAL RIGHT APPLICATION A00071 Fig. 6 - A- Coil in Horizontal- Right App...