Carrier COMFORT ZONE ZONEKIT4ZCAR- User Manual
Carrier COMFORT ZONE ZONEKIT4ZCAR– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – authorized and listed accessory conversion kit.; Burner sight glass for viewing burner flame.
- Page 4 – ama; Model number nomenclature; Input Capacity
- Page 5 – Mechanical air cleaner is shown.
- Page 7 – Performance data; EFFICIENCY
- Page 8 – Dimensions
- Page 9 – CONDENSATE TRAP; Assembled
- Page 10 – Combustion-air and vent piping
- Page 11 – MAXIMUM ALLOWABLE PIPE LENGTH (FT) Continued
- Page 12 – CONCENTRIC VENT
- Page 14 – Typical installations
- Page 16 – SERVICE TRAINING; • Unit Familiarization
Copyright 1996 Carrier Corporation
Form 58MCA-6PD
Product
Data
58MCA
4-Way Multipoise
Fixed-Capacity Direct-Vent
Condensing Gas Furnace
Series 131
Input Capacities: 40,000 thru 120,000 Btuh
®
High Efficiency and
Flexibility Designed to Meet
the Needs of New Homes
The model 58MCA combines high
efficiency with flexibility to meet the
changing needs of new home
construction. The unique 4-way,
multipoise design of the 58MCA
allows for installation in upflow,
downflow, horizontal left, and
horizontal right orientations,
meaning it is perfect for a variety
of installation applications. The
58MCA can be installed in a
manufactured (mobile) home when
the optional kit is used. The furnace
is factory configured for upflow
application but can easily be made
ready for downflow or horizontal
installation.
Horizontal applications offer the
advantage of reduced space
requirements by locating the furnace
in an attic or crawlspace, freeing
space formerly dedicated to a furnace
or utility room.
The 58MCA is specifically
designed to meet the needs of home
builders and new home owners.
Home builders benefit from the
58MCA’s unmatched flexibility and
by building a reputation of using
quality appliances in homes. Home
owners benefit by energy savings
from 1 of the most important home
appliances.
The components of the 58MCA
represent the finest in the industry.
Hot surface ignition (HSI) and an
integrated control center provide
reliable and efficient ignition. The
inducer and inducer motor are unique
in that efficient operation is achieved
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
3 NOTES: 1. The 58MCA Furnaces are for use with natural gas, but can be field-converted for propane gas with a factory- authorized and listed accessory conversion kit. 2. Component location and configuration may be different than shown above. Burner sight glass for viewing burner flame. Burner assem...
4 Carrier accessories* * Factory-authorized and field-installed. Gas conversion kits are A.G.A. recognized. † For 16 and 20 sizes only and in upflow application ONLY. See kit Installation Instructions for details.‡ Required for installation on combustible floors when no coil box is used, or when any...
5 A93067 RETURN-AIR PLENUM Custom-made return-air plenum can be mounted on either side of the furnace. Two framed wash-able filters included. A 25 in. B 16 in. C 39-7/8 in. A93086 CONCENTRIC VENT A concentric vent kit allows vent and combustion-air pipes toterminate through a single exitin a roof or...