Carrier AY060- User Manual
Carrier AY060– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – LEGEND; PLUG LOCATION REFERENCE
- Page 25 – Fig. 19 — Space Temperature Averaging Wiring
- Page 26 – Fig. 20 — Electric Heater Power Diagrams
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
PC 111
Catalog No. 534-80145
Printed in U.S.A.
Form 48/50A-1W
Pg 1
2-03
Replaces: New
Book 1
1
Tab
1a 1b
Wiring Diagrams
INDEX
ACCESSORIES
NOTE: Accessory wiring is shown on the unit wiring dia-
grams. Refer to the appropriate drawing for accessory wiring.
The following accessories are shown on the main control box
circuit drawing (Fig. 8): thermostat, remote economizer
position override, remote economizer minimum position set
point, remote 4-20 mA economizer position, and space IAQ
sensor. The following accessories are shown on the auxiliary
control box circuit drawing (Fig. 9): outdoor enthalpy
changeover sensor and differential enthalpy changeover
sensor. The following accessories are shown on the accessory
board wiring drawing (Fig. 10): outdoor air quality sensor,
remote supply air set point, demand limit controller, outdoor
inlet cfm sensor, fan status switch, demand limit-redline,
demand limit-loadshed, fire pressurization, fire evacuation, fire
smoke purge, and IAQ override switch.
ELECTRIC HEAT POWER DIAGRAMS
NOTE: All power leads connect to (single) TB7 power terminal block
– 2 or 3 conductors per terminal.
TYPE
UNIT
NUMBER
FIG. NO.
Component Arrangement
48/50AJ,AK,AW,AY020-035
48EJ502489
1
48/50AJ,AK,AW,AY040-060
48EJ502490
2
Power Schematic
48/50AJ,AK,AW,AY020-027
48EJ503085
3
48/50AJ,AK,AW,AY030-035
48EJ503084
4
48/50AJ,AK,AW,AY040
48EJ503083
5
48/50AJ,AK,AW,AY050
48EJ503082
6
48/50AJ,AK,AW,AY060
48EJ503081
7
Main Control Box Circuit
48/50AJ,AK,AW,AY020-060
48EJ503075
8
Auxiliary Control Box Wiring
48/50AJ,AK,AW,AY020-060
48EJ503076
9
Accessory Board Wiring
48/50AJ,AK,AW,AY020-060
48EJ503086
10
Gas Heat Control Circuit
(2-Stage Heat)
48AJ,AK,AW,AY020-050
48EJ503079
11
48AJ,AK,AW,AY060
48EJ503077
12
Gas Heat Control Circuit
(Staged Gas Heat)
48AJ,AW020-050
48EJ502488
13
48AJ,AW060
48EJ503078
14
Electric Heat Control Circuit
50AJ,AK,AW,AY020-050
48EJ503080
15
50AJ,AK,AW,AY060
48EJ503087
16
ACCESSORY
UNIT
FIG. NO.
Motormaster® V Low Ambient
Controller
48/50AJ,AK,AW,AY020-035
17
48/50AJ,AK,AW,AY040-060
18
Space Sensor Temperature
Averaging
48/50AJ,AK,AW,AY020-060
19
UNIT SIZES
ELEC CHARACTERISTICS
NOMINAL kW
FIG. NO.
QTY PER UNIT
Lo Heat
Hi Heat
020-050
208/230-3-60
36
72
20
2
460-3-60
380-3-60
400-3-50
36
24
27
72
49
54
20
2
575-3-60
36
72
20
2
060
208/230-3-60
54
108
20
3
460-3-60
380-3-60
400-3-50
54
37
41
108
74
82
20
3
575-3-60
54
108
20
3
48/50AJ,AK,AW,AY020-060
Single Package Rooftop
Gas Heating/Electric Cooling and Electric Cooling Units
with
Comfort
Link™ Controls
50/60 Hz
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 LEGEND AND NOTES FOR FIG. 1-16 LEGEND BP — Building Pressure C — Contactor, Compressor CAP — Capacitor CB — Circuit Breaker CCB — Control Circuit Breaker CCH — Crankcase Heater CCN — Carrier Communication Network COMP — Compressor Motor CR — Control Relay CS — Compressor Safety CSB — Current Sensi...
25 SPACE TEMPERATURE AVERAGING — 4 SENSOR APPLICATION SPACE TEMPERATURE AVERAGING — 9 SENSOR APPLICATION Fig. 19 — Space Temperature Averaging Wiring
26 36 kW, 208/230 V, SIZES 020-050 54 kW, 208/230 V, SIZE 060 72 kW, 208/230 V, SIZES 020-050 108 kW, 208/230 V, SIZE 060 36 kW, 460 V, SIZES 020-05024 kW, 380 V, SIZES 020-05027 kW, 400 V, SIZES 020-050 54 kW, 460 V, SIZE 06037 kW, 380 V, SIZE 06041 kW, 400 V, SIZE 060 36 kW, 575 V, SIZES 020-050 5...