Wiring Diagrams

INDEX

MODEL NO.

TYPE

VOLTAGE (1 Ph, 60 Hz)

FIGURE NO.

LABEL DIAGRAM

Heat Pumps

52EQ

EC

208/230,

265

1

52EQ500054

52SQ

AA/CP

208/230,

265

2

52SQ502304

RC

208/230,

265

3

50SQ502384

Heat/Cool Units

52EE

EC

208/230,

265

1

52EQ500054

52SC

AA/CP

208/230,

265

4

52SQ500164

52SE

AA/CP

208/230,

265

5

52SE500374

RC

208/230,

265

6

52SE500384

ACCESSORY

Item

Model No.

Figure No.

Label Diagram

Energy Management (EM) Kit

EM-KIT

7

52SQ506072

LEGEND

AA — Standard Chassis (52S)
CP — Corrosion Protection
EC — Standard Chassis (52E)
RC — Remote Control

LEGEND

CAP

Capacitor

CENT

Central

COM

Common

COMM

Communication

COMP

Compressor

CONCYC — Continuous Cycle
CR

Cooling Relay

CW

Clockwise

EQUIP

Equipment

FCS

Fan Cycle Switch

FGT

Freeze Guard Thermostat

FM

Fan Motor

FR

Fan Relay

GND

Ground

HERM

Hermetic

HR

Heating Relay

HTR

Heater

ID

Indoor

IFT

Indoor Frost Thermostat

IT

Indoor Thermostat

LS

Limit Switch

NO

Normally Open

OD

Outdoor

OFT

Outdoor Frost Thermostat

OL

Overload

PL

Plug

PLS

Primary Limit Switch

PR

Primary Relay

RVR

Reversing Valve Relay

RVS

Reversing Valve Solenoid

SCM

Standard Control Module

SLS

Secondary Limit Switch

SSS

Speed Selector Switch

ST

Start Thermistor

SW

Switch

TB

Terminal Board

TRANS

Transformer

U/L

Upper/Lower

UNOCC — Unoccupied

Marked Connection

Unmarked Connection

Terminal Board

Factory-Installed Wiring

Field-Installed (or Optional) Wiring

Field (Main) Power Supply

To |indicate common potential
only. Not to represent wire

NOTES:
1. Recommended for use on grounded power supply only.
2. Compressor and fan motor thermally protected.
3. Use copper conductors only.
4. All wiring must conform to NEC (National Electrical Code) and local codes.
5. Dashed boxes show start thermistor, reversing valve solenoid, and plug, when used.
6. Control center uses thermostat part number HH01AD045 or equivalent (Fig. 3, 6).
7. Field control wirie suitable for NEC, Class 2 control circuit at 24 volts (Fig. 3, 6).

52E,S

Packaged Terminal

Air Conditioners and Heat Pumps

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book 1

4

Tab

9a 11a

PC 132

Catalog No. 535-207

Printed in U.S.A.

Form 52E,S-3W

Pg 1

10-97

Replaces: 50E,S-2W

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Carrier Models