Carrier AQUAZONE 50VQL080-300- User Manual

Carrier AQUAZONE 50VQL080-300

Carrier AQUAZONE 50VQL080-300– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
Page: / 60

Table of Contents:

  • Page 2 – Puron; Table of contents
  • Page 5 – ARI/ISO capacity ratings; 0VQP UNIT CAPACITY RATINGS; Model number nomenclature; B C C 5 0 1 A 1
  • Page 6 – 0VQP UNIT PHYSICAL DATA; Physical data
  • Page 7 – Factory-installed options; Options and accessories
  • Page 8 – Field-installed accessories
  • Page 9 – AQUAZONETM THERMOSTATS
  • Page 10 – Dimensions
  • Page 12 – Selection procedure (50VQP096 unit example)
  • Page 14 – Performance data
  • Page 23 – ANTIFREEZE CORRECTION TABLE; DRY COIL TO WET COIL CONVERSION TABLE
  • Page 36 – ELECTRICAL DATA — STANDARD UNIT; Electrical data
  • Page 37 – ELECTRICAL DATA — DUAL POINT POWER UNIT
  • Page 38 – Typical piping and wiring
  • Page 39 – Typical control wiring schematics
  • Page 43 – 0VQP UNIT WITH COMPLETE C AND WSHP OPEN CONTROLLER (208/230 V)
  • Page 44 – PREMIERLINKTM CONTROLLER APPLICATIONS WITH COMPLETE C CONTROL
  • Page 45 – WSHP OPEN CONTROL
  • Page 46 – AQUAZONE PRODUCT GUIDE; Water loop system; Application data
  • Page 47 – Condensate drainage; Venting —; Water conditioning
  • Page 48 – WATER QUALITY GUIDELINES
  • Page 49 – Acoustical design; ASSOCIATED WITH NC CURVES; WSHP sound control
  • Page 50 – If; OPERATING LIMITS; Solenoid valves
  • Page 51 – WSHP Open sequence of operation; Scheduling —; Controls
  • Page 53 – Waterside economizer —; Cooling
  • Page 54 – Demand limit —; The WSHP Open controller has the; Condenser water linkage —; The control provides opti-
  • Page 55 – Refrigerant; HVAC Guide Specifications; Guide specifications
  • Page 56 – Comfort
Loading the manual

Copyright 2009 Carrier Corporation

Form 50VQP-1PD

Single-package vertically mounted
water source heat pumps (WSHPs)
with electronic controls.
• Non-ozone depleting Puron

refrigerant (R-410A)

• Performance certified to ARI/ISO/

ASHRAE 13256-1

• Wide application use with operating

temperature range of 20 F to 110 F

• Dual refrigerant circuits for 2-stage

operation

• High-efficiency scroll compressors
• Thermostatic expansion valve (TXV)

provides efficient and reliable
refrigerant flow

• High-static capability available
• Available mute package for quiet

operation

• Available low temperature insulation

to prevent condensation

• Easy service access
• Flexible and reliable multiple

protocol WSHP Open controller can
use BACnet*, Modbus†, N2, and
LON** (with separate card)
protocols for integrating energy
efficiency and precise unit control

Features/Benefits

Carrier’s Aquazone™ large
capacity units offer low cost,
energy efficient solutions for
all challenging water source
heat pump applications.

Operating efficiency

Carrier’s Aquazone large capacity
vertical water source heat pumps are
designed for quality and high perfor-
mance over a lifetime of operation.
Aquazone units offer cooling EERs
(Energy Efficiency Ratio) to 21.4 and
heating COPs (Coefficient of Perfor-
mance) to 5.1.

AQUAZONE™

50VQP084-300

Vertical Large Capacity

Water Source Heat Pumps

with PURON

®

Refrigerant (R-410A)

7

to 25 Nominal Tons

Product
Data

TM

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Puron; Table of contents

2 Efficiencies stated are in accordance with standard conditions under ISO (International Organization for Stan-dardization) Standard 13256-1 and pro-vide among the highest ratings in the industry, exceeding ASHRAE (Ameri-can Society of Heating, Refrigerant and Air Conditioning Engineers) 90.1 Energ...

Page 5 - ARI/ISO capacity ratings; 0VQP UNIT CAPACITY RATINGS; Model number nomenclature; B C C 5 0 1 A 1

5 ARI/ISO capacity ratings 50VQP UNIT CAPACITY RATINGS LEGEND NOTES: 1. Cooling capacities based upon 80.6 F db, 66.2 F wb entering air temperature. 2. Heating capacities based upon 68 F db, 59 F wb entering air temperature. 3. All ratings based upon operation at lower voltage of dual voltage rated ...

Page 6 - 0VQP UNIT PHYSICAL DATA; Physical data

6 50VQP UNIT PHYSICAL DATA LEGEND NOTES: 1. All units have grommet and spring compressor mountings, and 1 / 2 in. and 1 3 / 4 in. electrical knockouts. 2. Use the lowest maximum pressure rating when multiple options are combined: 50VQP UNIT SIZE 084 096 120 150 168 192 240 300 NOMINAL AIRFLOW (cfm) ...