Carrier AQUASNAP 30MPA- User Manual
Carrier AQUASNAP 30MPA– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Comfort; Fig. 3 — 30MP Model Number Nomenclature; LEGEND; EMM —; Energy Management Module; LON —; Local Operating Network; UPC —; Unitary Protocol Controller
- Page 3 – ig
- Page 5 – Table 1A — 30MPA Air-Cooled and 30MPW Liquid-Cooled Units — English; * With optional hot gas
- Page 6 – Table 1B — 30MPA Air-Cooled and 30MPW Liquid-Cooled Units — SI
- Page 7 – Step 3 — Place the Unit; These units are not suitable for unprotected outdoor; Step 4 — Check Compressor Mounting —; must not; IDE; WEIGHT DISTRIBUTION AT EACH MOUNTING; MOUNTING HOLE; Fig. 6 — Mounting Hole Weight Distribution
- Page 8 – le
- Page 11 – Fig. 11 — Condenser Water Pressure Drop; ENGLISH
- Page 12 – Fig. 12 — Evaporator Water Pressure Drop
- Page 13 – Step 6 — Fill the Chilled Water Loop; Table 2 — Water Quality Characteristics; CAUTION
- Page 14 – Step 7 — Make Electrical Connections —; must; Never; Fig. 14 — Typical Set Up for Cleaning Process; Fig. 15 — Cleaning Using a Side Stream Filter
- Page 15 – This amount of phase imbalance is satisfactory as it is below; Table 3 — Electrical Data — 30MPA,MPW Units; IMPORTANT: If the supply voltage phase imbalance
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53300054-01
Printed in U.S.A.
Form 30MP-1SI
Pg 1 910
1-10
Replaces: New
Installation Instructions
CONTENTS
Page
GENERAL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY CONSIDERATIONS
. . . . . . . . . . . . . . . . . . . 1,2
INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16
Location
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Step 1
— Inspect Shipment
. . . . . . . . . . . . . . . . . . . . 2
Step 2
— Position the Unit
. . . . . . . . . . . . . . . . . . . . . 2
Step 3
— Place the Unit
. . . . . . . . . . . . . . . . . . . . . . . . 7
Step 4
— Check Compressor Mounting
. . . . . . . . 7
Step 5
— Make Piping Connections
. . . . . . . . . . . . 7
• 30MPA SYSTEM CONDENSER
• 30MPW CONDENSER DESCRIPTION
• 30MPW CONDENSER
• EVAPORATOR DESCRIPTION
• EVAPORATOR PIPING
• AIR SEPARATION
Step 6
— Fill the Chilled Water Loop
. . . . . . . . . . .13
• WATER SYSTEM CLEANING
• FILLING THE SYSTEM
Step 7
— Make Electrical Connections
. . . . . . . . .14
• FLOW SWITCH
• CONTROL BOX, POWER SECTION
• CONTROL BOX, CONTROLS SECTION
• CONTROL BOX, FIELD CONTROL WIRING
SECTION
• UNBALANCED 3-PHASE SUPPLY VOLTAGE
GENERAL
These installation instructions cover the 30MPA, MPW units
with
Comfort
Link controls. The 30MPA units are condenserless
units and the 30MPW units are all fluid cooled.
SAFETY CONSIDERATIONS
Installing, starting up, and servicing this equipment (Fig. 1
and 2) can be hazardous due to system pressures, electrical
components, and equipment location (roofs, elevated struc-
tures, etc.). Model number structure is shown in Fig. 3.
Only trained, qualified installers and service technicians
should install, start up, and service this equipment.
When working on the equipment, observe precautions in the
literature and on tags, stickers, and labels attached to the
equipment.
• Follow all safety codes.
• Wear safety glasses and work gloves.
• Use care in handling, rigging, and setting bulky
equipment.
.
WARNING
Electrical shock can cause personal injury and death. Shut
off all power to this equipment during installation. There
may be more than one disconnect switch. Tag all discon-
nect locations to alert others not to restore power until work
is completed.
Fig. 1 — 30MPA Unit
a30-5029
Fig. 2 — 30MPW Unit
a30-5030
AQUASNAP
®
30MPA,MPW015-045
Liquid Chillers
with Scroll Compressors
and
COMFORTLINK
™ Controls
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 INSTALLATION Location — Do not store units in an area exposed to weath- er because of sensitive control mechanisms and electronic devices. Locate unit indoors. See Fig. 4 and 5 for unit dimen- sional details. When considering location, consult National Electrical Code (NEC) and local code requirem...
3 52.30 1328 [] STD UNIT 55.00 1397 [] OPTIONAL SOUND ENCLOSURE 57.00 [1448] 29.13 740 [] STD UNIT 32.00 813 [] 62.50 1588 [] OPTIONAL SOUND ENCLOSURE 32.12 [816] MOBILITY KIT (WHEEL) OPTIONAL 3.85 98 [] E D F OPTIONAL SOUND ENCLOSURE 48.42 [1230] OPTIONAL SOUND ENCLOSURE 65.05 [1652] 4.00 [102] ISO...
5 Table 1A — 30MPA Air-Cooled and 30MPW Liquid-Cooled Units — English * With optional hot gas b ypass. NOTES: 1. Operating weight includes refrigerant operating charge and weight of fluid in the heat exchangers. 2. 30MPW units are shipped with full operating charge. UNIT 30MPA,MPW 015 020 030 040 04...