Carrier 50XCA06-24 - Manual
Carrier 50XCA06-24 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Environmentally sound; Table of contents
- Page 3 – AHRI* capacity ratings; Model number nomenclature
- Page 4 – Physical data
- Page 7 – Selection procedure (50XCA08 unit example); SERVICE CLEARANCE
- Page 8 – Performance data
- Page 26 – Electrical data
- Page 28 – Typical wiring schematic
- Page 30 – Operating sequence; Controls
- Page 31 – Typical piping and wiring
- Page 32 – Application data
- Page 33 – Setting condenser fan speed
- Page 34 – HVAC Guide Specifications; Guide specifications
Copyright 2010 Carrier Corporation
Form 50XCA-1PD
The 50XCA single-package cooling
units with integral air-cooled condensers
offer:
• Compact, durable, and attractive
cabinet fits any working environment
• Available in ducted or free return with
rear return connections with vertical
supply air discharge
• Provides high-efficiency cooling for
commercial and industrial projects
• Rear condenser inlet and discharge
and belt drive condenser fan permit
condenser air connections to be
ducted through window or wall louver
• Uses Puron
®
refrigerant (R-410A)
Features/Benefits
The Omnizone 50XCA units
provide a practical and
economical approach to
comfort conditioning
requirements for offices,
factories, and other
applications in existing
buildings when indoor air-
cooled condensers are
required.
Design flexibility
The 50XCA indoor packaged units are
designed to provide the flexibility re-
quired in replacement, renovation, and
new construction. Units are available in 6
sizes from 5 tons to 20 tons which meet
the needs for cooling restaurants, retail
stores, warehouses, offices, and building
additions.
OMNIZONE™
50XCA06-24
Air-Cooled
Indoor Self-Contained Systems
with
PURON
®
Refrigerant (R-410A)
5 to 20 Nominal Tons
Product
Data
a50-8499
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 The compact footprint and service from the front of the units save valu-able floor space in equipment rooms. Belt drive condensers provide adequate static to overcome ducting and louver static losses. This allows units to be po-sitioned against an existing window or wall louver, or ducted to the o...
3 AHRI* capacity ratings LEGEND *AHRI — Air Conditioning, Heating, and Refrigeration Institute. NOTE: Unit is tested in accordance with AHRI standard 340/360. UNIT 50XCA NOMINAL TONS EVAPORATOR CFM CONDENSER CFM NET COOLING (Btuh) TOTAL kW EER IEER 06 5 1,875 2,800 65,000 5.8 11.2 11.4 08 7 1 / 2 2,...
4 LEGEND UNIT 50XCA 06 08 12 14 16 24 NOMINAL CAPACITY (tons) 5 7 1 / 2 10 12 15 20 UNIT OPERATING WEIGHT (lb) 891 1144 1269 1298 1575 2000 COMPRESSOR Copeland S croll Compressor Model ZP57 ZP67 ZP51 ZP57 ZP72 ZP103 Qty 1 1 2 2 2 2 Steps of Control 1 1 2 2 2 2 Operating Charge R-410A (lb) 17.4 21.4 ...