Carrier 50TCQA- Manual
Carrier 50TCQA– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – ELECTRICAL SHOCK HAZARD; UNIT OPERATION AND SAFETY HAZARD; WARNING; PERSONAL INJURY AND ENVIRONMENTAL; WARNING; CUT HAZARD; CAUTION
- Page 4 – INSTALLATION; Jobsite Survey; Step 1 — Plan for Unit Location; NOTE
- Page 5 – Ductwork must be attached to curb and
- Page 7 – MAXIMUM ALLOWABLE; Step 5 — Field Fabricate Ductwork; Do not connect ductwork to; Step 6 — Rig and Place Unit; UNIT DAMAGE HAZARD
- Page 8 – Positioning on Curb —; Step 7 — Convert to Horizontal and Connect; without; Step 8 — Install Outside Air Hood; Economizer Hood Removal and Setup -- Factory; Economizer Hood and Two–Position Hood
- Page 9 – Economizer Hood and
- Page 10 – Step 9 — Install External Condensate Trap and
- Page 11 – Step 10 — Make Electrical Connections; FIRE HAZARD; Units Without Factory--Installed Disconnect —
- Page 12 – Units with Factory--Installed Disconnect —; Units Without Disconnect Option; Convenience Outlets —; Installing Weatherproof Cover –
- Page 15 – Electric Heaters; Bare Heater Model Number
- Page 16 – Single Point Boxes and Supplementary Fuses —; Single Point Boxes without Fuses —
- Page 17 – PremierLink; Temperature (SAT) Sensor on Small Rooftop Units
- Page 20 – Table 3 – PremierLink Sensor Usage
- Page 23 – Connections; COVER REMOVED; Sensor Connections
- Page 24 – Connection
- Page 25 – CCN Bus
- Page 28 – Table 8 – RTU--MP Controller Inputs and Outputs
- Page 29 – Economizer controls —; Return Air
- Page 30 – Sensor; Connecting Discrete Inputs
- Page 31 – SW3 Protocol Selection; Baud Rate Selections
- Page 32 – Local Access; BACview; Communication LEDs; Handheld Connections
- Page 33 – Table 9 – LEDs; Tx; Integration Guide; SMOKE DETECTORS; Completing Installation of Return Air; System
- Page 34 – Smoke Detector Locations; Location
- Page 35 – Completing Installation of Return Air Smoke; Flexible
- Page 36 – Table 10 – Unit Wire/MOCP Sizing Data; : See page 44 for table legend and notes.
- Page 44 – Legend and Notes for Table 10; IV Wiring; Step 11 — Adjust Factory--Installed Options; Smoke Detectors —
- Page 45 – Step 12 — Install Accessories
50TCQA
Single Package Rooftop
Heat Pump
with Puron
r
(R --- 410A) Refrigerant
Sizes 04 --- 07
Installation Instructions
NOTE
: Read the entire instruction manual before starting
the installation
TABLE OF CONTENTS
SAFETY CONSIDERATIONS
1
. . . . . . . . . . . . . . . . . . . .
INSTALLATION
4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Step 1 -- Plan for Unit Location
4
. . . . . . . . . . . . . . . . . .
Step 2 -- Plan for Sequence of Unit Installation
5
. . . . . .
Step 3 -- Inspect Unit
5
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Step 4 -- Provide Unit Support
5
. . . . . . . . . . . . . . . . . . .
Step 5 -- Field Fabricate Ductwork
7
. . . . . . . . . . . . . . . .
Step 6 -- Rig and Place Unit
7
. . . . . . . . . . . . . . . . . . . . .
Step 7 -- Convert to Horizontal & Connect Ductwork
8
.
Step 8 -- Install Outside Air Hood
8
. . . . . . . . . . . . . . . .
Step 9 -- Install External Condensate Trap and Line
10
.
Step 10 -- Make Electrical Connections
11
. . . . . . . . . . .
Step 11 -- Adjust Factory--Installed Options
44
. . . . . . . .
Step 12 -- Install Accessories
45
. . . . . . . . . . . . . . . . . . .
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical
shock or other conditions which may cause personal
injury or property damage. Consult a qualified installer,
service agency, or your distributor or branch for
information or assistance. The qualified installer or
agency must use factory--authorized kits or accessories
when modifying this product. Refer to the individual
instructions packaged with the kits or accessories when
installing.
Follow all safety codes. Wear safety glasses and work
gloves. Use quenching cloths for brazing operations and
have a fire extinguisher available. Read these instructions
thoroughly and follow all warnings or cautions attached to
the unit. Consult local building codes and appropriate
national electrical codes (in USA, ANSI/NFPA70,
National Electrical Code (NEC); in Canada, CSA C22.1)
for special requirements.
It is important to recognize safety information. This is the
safety--alert symbol
. When you see this symbol on the
unit and in instructions or manuals, be alert to the
potential for personal injury.
Understand the signal words DANGER, WARNING,
CAUTION, and NOTE. These words are used with the
safety--alert symbol. DANGER identifies the most serious
hazards which
will
result in severe personal injury or
death. WARNING signifies hazards which
could
result in
personal injury or death. CAUTION is used to identify
unsafe practices, which
may
result in minor personal
injury or product and property damage. NOTE is used to
highlight suggestions which
will
result in enhanced
installation, reliability, or operation.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Carrier 50TCQA
Summary
2 ELECTRICAL SHOCK HAZARD Failure to follow this warning could cause personal injury or death.Before performing service or maintenance operations on unit, always turn off main power switch to unit and install lockout tag. Unit may have more than one power switch. ! WARNING UNIT OPERATION AND SAFETY ...
4 C09002 Fig. 1 -- Unit Dimensional Drawing – 04 — 07 Size Unit (cont.) INSTALLATION Jobsite Survey Complete the following checks before installation. 1. Consult local building codes and the NEC (National Electrical Code) ANSI/NFPA 70 for special installa- tion requirements. 2. Determine unit locati...
5 Roof mount — Check building codes for weight distribution requirements. Unit operating weight is shown in Table 1. Step 2 — Plan for Sequence of Unit Installation The support method used for this unit will dictate different sequences for the steps of unit installation. For example, on curb--mounte...