Carrier 50PSW036-360 - Manual

Carrier 50PSW036-360

Carrier 50PSW036-360 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – LEGEND
  • Page 3 – cm
  • Page 4 – FPT —; Female Pipe Thread; CAUTION
  • Page 5 – not; Fig. 3 — Typical Water Loop System —
  • Page 6 – Table 2 — Water Quality Guidelines
  • Page 7 – Step 6 — Wire Electrical Connections; Table 3 — 50PSW Electrical Data; WARNING
  • Page 12 – Step 7 — Wire Low Voltage Connections; only; System Checkout —; Fig. 8 — Typical Field Wiring; Typical; Fig. 10 — Typical Aquazone Accessory Wiring
  • Page 13 – Table 4 — DIP Switch Block S2 —
  • Page 14 – Scroll Compressor Rotation —
  • Page 15 – Table 7 — Heat Exchanger Pressure Drop; NOTE: Bold values indicate use of antifreeze is re; Cleaning and Flushing —; UNIT SIZE
  • Page 16 – per 30 M of Pipe; Table 9 — Antifreeze Percentages by Volume; Internal Pipe Size; CC; Fig. 11 — Test Mode Pins Location
  • Page 17 – Retry Mode —; Table 10 — Complete C Control Current LED
  • Page 19 – Fig. 14 — Thermistor Nominal Resistance
  • Page 20 – Fig. 15 — FP1 and FP2 Thermistor Location; COAX —; uid Line Flow
  • Page 21 – Table 13 — Troubleshooting
  • Page 24 – HEATING AND COOLING CYCLE ANALYSIS; = SUCTION TEMPERATURE – SUCTION SATURATION TEMPERATURE; SUBCOOLING; = DISCHARGE SATURATION TEMPERATURE – LIQUID LINE TEMPERATURE; DESCRIPTION; REVERSING; COAX; Source
Loading the manual

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Catalog No. 04-53500073-01

Printed in U.S.A.

Form 50PSW-C1SI

Pg 1

10-10

Replaces: New

Installation, Start-Up, and

Service Instructions

CONTENTS

Page

SAFETY CONSIDERATIONS

. . . . . . . . . . . . . . . . . . .1,2

GENERAL

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12

Step 1 — Check Jobsite

. . . . . . . . . . . . . . . . . . . . . . . . 2

Step 2 — Check Unit

. . . . . . . . . . . . . . . . . . . . . . . . . . . 2

• STORAGE

• PROTECTION

• INSPECT UNIT

Step 3 — Locate Unit

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Step 4 — Mount Unit

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Step 5 — Connect Piping

. . . . . . . . . . . . . . . . . . . . . . . . . 5

• WATER SUPPLY AND QUALITY

• WATER LOOP APPLICATIONS

• GROUND-WATER APPLICATIONS

• GROUND-LOOP APPLICATIONS

• UNIT LOAD PIPING

Step 6 — Wire Electrical Connections

. . . . . . . . . . . . 7

• POWER CONNECTION

• SUPPLY VOLTAGE

• EXTERNAL LOOP POWER CONNECTION

• 220-V OPERATION

• 380-V OPERATION

Step 7 — Wire Low Voltage Connections

. . . . . . . . 12

• THERMOSTAT CONNECTIONS

• WATER FREEZE PROTECTION

• ACCESSORY CONNECTIONS

• WATER SOLENOID VALVES

PRE-START-UP

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

System Checkout

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

FIELD SELECTABLE INPUTS

. . . . . . . . . . . . . . . .13,14

Complete C Control Jumper Settings

. . . . . . . . . . . 13

Complete C Control DIP Switches

. . . . . . . . . . . . . . 13

Deluxe D Control Jumper Settings

. . . . . . . . . . . . . 13

Deluxe D Control DIP Switches

. . . . . . . . . . . . . . . . 13

Deluxe D Control Accessory Relay

Configurations

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

START-UP

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-16

Operating Limits

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Unit Start-Up

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Scroll Compressor Rotation

. . . . . . . . . . . . . . . . . . . . . 14

Flow Regulation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Cleaning and Flushing

. . . . . . . . . . . . . . . . . . . . . . . . . . 15

Antifreeze

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Cooling Tower/Boiler Systems

. . . . . . . . . . . . . . . . . . 16

Ground Coupled, Closed Loop and Plateframe

Heat Exchanger Well Systems

. . . . . . . . . . . . . . . . 16

OPERATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Power Up Mode

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Units with Aquazone Complete C Control

. . . . . . . 16

Units with Aquazone Deluxe D Control

. . . . . . . . . . 16

SYSTEM TEST

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16,17

Page

Test Mode

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Retry Mode

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Aquazone Deluxe D Control LED Indicators

. . . . . 17

SERVICE

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18,19

Water Coil

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Refrigerant System

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Condenser Cleaning

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Checking System Charge

. . . . . . . . . . . . . . . . . . . . . . . 19

Refrigerant Charging

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

TROUBLESHOOTING

. . . . . . . . . . . . . . . . . . . . . . . . 19-21

50PSW START-UP CHECKLIST

. . . . . . . . . . . CL-1,CL-2

SAFETY CONSIDERATIONS

Installation and servicing of air-conditioning equipment can

be hazardous due to system pressure and electrical compo-

nents. Only trained and qualified service personnel should

install, repair, or service air-conditioning equipment.

Untrained personnel can perform basic maintenance func-

tion of cleaning coils. All other operations should be performed

by trained service personnel. When working on air-condition-

ing equipment, observe precautions in the literature, tags and

labels attached to the unit, and other safety precautions that

may apply.

Improper installation, adjustment, alteration, service, main-

tenance, or use can cause explosion, fire, electrical shock or

other conditions which may cause personal injury or property

damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The

qualified installer or agency must use factory-authorized kits or

accessories when modifying this product. Refer to the individ-

ual instructions packaged with the kits or accessories when

installing.

Follow all safety codes. Wear safety glasses and work

gloves. Use quenching cloth for brazing operations. Have fire

extinguisher available. Read these instructions thoroughly and

follow all warnings or cautions attached to the unit. Consult

local building codes and the National Electrical Code (NEC,

U.S.A.) for special installation requirements.

Understand the signal words — DANGER, WARNING,

and CAUTION. DANGER identifies the most serious hazards

which will result in severe personal injury or death. WARN-

ING signifies hazards that could result in personal injury or

death. CAUTION is used to identify unsafe practices, which

would result in minor personal injury or product and property

damage.

IMPORTANT: Read the entire instruction manual before

starting installation.

AQUAZONE™

50PSW036-360

Water-to-Water Water Source Heat Pump

with PURON

®

Refrigerant (R-410A)

50 Hz

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - LEGEND

2 Recognize safety information. This is the safety alert symbol ( ). When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. GENERAL The Aquazone™ 50PSW water source heat pump (WSHP) is a single-package vertically mounted unit with electron...

Page 3 - cm

3 B C A M L K 2.5 cm 1 2 3 4 5 6 J H G F E D Req u ired S ervice Acce ss Option a l S ervice Acce ss 2.5 cm 4.6 cm 1 2 3 4 5 6 Req u ired S ervice Acce ss Option a l S ervice Acce ss B C A 3 . 3 cm 6.9 cm 1 8 .5 cm 4. 3 cm Fig. 1 — 50PSW036-120 Unit SIZES 036,060 LEGEND NOTES: 1. Dimensions shown in...

Page 4 - FPT —; Female Pipe Thread; CAUTION

4 PROTECTION — Once the units are properly positioned on the jobsite, they must be covered with either a shipping carton, vinyl film, or an equivalent protective covering. Open ends of pipes stored on the jobsite must be capped. This precaution is especially important in areas where painting, plaste...

Other Carrier Models