Carrier 50HCQA- Manual
Carrier 50HCQA– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – SAFETY CONSIDERATIONS; WARNING
- Page 4 – INSTALLATION; Jobsite Survey; Step 1 — Plan for Unit Location; NOTE
- Page 5 – Ductwork must be attached to curb and
- Page 7 – MAXIMUM ALLOWABLE; Step 5 — Field Fabricate Ductwork; Do not connect ductwork to; For Units with Accessory Electric Heaters —; Step 6 — Rig and Place Unit; UNIT DAMAGE HAZARD; CAUTION
- Page 8 – Positioning on Curb —; Step 7 — Convert to Horizontal and Connect; without
- Page 9 – Step 8 — Install Outside Air Hood; Factory Option —; Economizer Hood and Two–Position Hood; Two Position Damper Hood Removal and Setup --; Economizer Hood and Two–Position; Hood Parts
- Page 10 – Step 9 — Install External Condensate Trap and
- Page 11 – Step 10 — Make Electrical Connections; ELECTRICAL SHOCK HAZARD; FIRE HAZARD; Units Without Factory--Installed Disconnect —
- Page 12 – Units with Factory--Installed Disconnect —; Units Without Disconnect Option; Convenience Outlets —; Installing Weatherproof Cover:
- Page 15 – Electric Heaters; Bare Heater Model Number
- Page 16 – Single Point Boxes and Supplementary Fuse; Single Point Boxes without Fuses:
- Page 17 – PremierLink; Temperature (SAT) Sensor on Small Rooftop Units
- Page 19 – Field Connections; SEN; SET; Connect Thermostat —
- Page 20 – Table 3 – PremierLink Sensor Usage; NOTES
- Page 22 – Economizer Controls
- Page 25 – CCN Bus
- Page 28 – Table 8 – RTU--MP Controller Inputs and Outputs; LEGEND
- Page 29 – Outdoor Air Enthalpy Control
- Page 31 – SW3 Protocol Selection; PROTOCOL; Baud Rate Selections; BAUD RATE
- Page 33 – Integration Guide; Smoke Detectors
- Page 34 – Smoke Detector Locations; Supply Air —; Location
- Page 35 – Return Air with Economizer —; Sampling Tube; Additional Application Data —
- Page 36 – : See page 42 for table legend and notes.
- Page 42 – Legend and Notes for Table 10; IMPORTANT; IV Wiring; Step 11 — Adjust Factory--Installed Options; Smoke Detectors —
- Page 43 – Step 12 — Install Accessories
1
50HCQA
Single Package Rooftop
Heat Pump
with Puron
r
(R --- 410A) Refrigerant
Sizes 04 --- 06
Installation Instructions
NOTE
: Read the entire instruction manual before starting
the installation
TABLE OF CONTENTS
SAFETY CONSIDERATIONS
2
. . . . . . . . . . . . . . . . . . . .
INSTALLATION
4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Jobsite Survey
4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Step 1 -- Plan for Unit Location
4
. . . . . . . . . . . . . . . . . .
Roof Mount
5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Step 2 -- Plan for Sequence of Unit Installation
5
. . . . . .
Curb--Mount Installation
5
. . . . . . . . . . . . . . . . . . . . .
Pad--Mount Installation
5
. . . . . . . . . . . . . . . . . . . . . .
Frame--Mount Installation
5
. . . . . . . . . . . . . . . . . . . .
Step 3 -- Inspect Unit
5
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Step 4 -- Provide Unit Support
5
. . . . . . . . . . . . . . . . . . .
Roof Curb Mount
5
. . . . . . . . . . . . . . . . . . . . . . . . . .
Slab Mount (Horizontal Units Only)
5
. . . . . . . . . . .
Alternate Unit Support
5
. . . . . . . . . . . . . . . . . . . . . .
Step 5 -- Field Fabricate Ductwork
7
. . . . . . . . . . . . . . . .
For Units with Accessory Electric Heaters
7
. . . . . .
Step 6 -- Rig and Place Unit
7
. . . . . . . . . . . . . . . . . . . . .
Positioning on Curb
8
. . . . . . . . . . . . . . . . . . . . . . . .
Step 7 -- Convert to Horizontal & Connect Ductwork
8
. .
Step 8 -- Install Outside Air Hood
9
. . . . . . . . . . . . . . . .
Economizer Hood Removal and Setup
9
. . . . . . . . .
Two Position Damper Hood Removal and Setup
9
. . .
Economizer Hood and Two--Position Hood
10
. . . . .
Step 9 -- Install External Condensate Trap and Line
10
. . .
Step 10 -- Make Electrical Connections
11
. . . . . . . . . . .
Field Power Supply
11
. . . . . . . . . . . . . . . . . . . . . . . .
Units without Factory--Installed Disconnect
11
. . . .
Units with Factory--Installed Disconnect
12
. . . . . . .
Convenience Outlets
12
. . . . . . . . . . . . . . . . . . . . . . .
Factory--Option Thru--Base Connections
13
. . . . . . .
Units without Thru--Base Connections
14
. . . . . . . . .
Field Control Wiring
14
. . . . . . . . . . . . . . . . . . . . . . .
Thermostat
14
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unit without Thru--Base Connection Kit
14
. . . . . . .
Heat Anticipator Settings
14
. . . . . . . . . . . . . . . . . . .
Electric Heaters
15
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Point Boxes and Supplementary Fuses
16
. . . . .
PremierLink
t
(Factory Option)
17
. . . . . . . . . . . . . . . . .
Supply Air Temperature (SAT) Sensor
17
. . . . . . . . .
Outdoor Air Temperature (OAT) Sensor
19
. . . . . . .
EconoMi$er
t
2
19
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Field Connections
19
. . . . . . . . . . . . . . . . . . . . . . . . . .
Space Temperature (SPT) Sensors
19
. . . . . . . . . . . .
Connect Thermostat
19
. . . . . . . . . . . . . . . . . . . . . . .
Configure the Unit for Thermostat Mode
22
. . . . . .
Economizer Controls
22
. . . . . . . . . . . . . . . . . . . . . . . .
Outdoor Air Enthalpy Control
22
. . . . . . . . . . . . . . .
Differential Enthalpy Control
22
. . . . . . . . . . . . . . . .
Return Air Enthalpy Sensor
22
. . . . . . . . . . . . . . . . .
Indoor Air Quality (CO
2
sensor)
22
. . . . . . . . . . . . .
Outdoor Air Quality Sensor
23
. . . . . . . . . . . . . . . . .
Smoke Detector/Fire Shutdown (FSD)
23
. . . . . . . . .
Filter Status Switch
24
. . . . . . . . . . . . . . . . . . . . . . . .
Supply Fan Status Switch
24
. . . . . . . . . . . . . . . . . . .
Remote Occupied Switch
24
. . . . . . . . . . . . . . . . . . .
Space Relative Humidity Sensor
24
. . . . . . . . . . . . .
Power Exhaust (output)
24
. . . . . . . . . . . . . . . . . . . . .
CCN Communication Bus
24
. . . . . . . . . . . . . . . . . .
RTU--MP Control System
26
. . . . . . . . . . . . . . . . . . . . . .
Supply Air Temperature (SAT) Sensor
28
. . . . . . . . .
Outdoor Air Temperature (OAT) Sensor
28
. . . . . . .
EconoMi$er
t
2
28
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Field Connections
29
. . . . . . . . . . . . . . . . . . . . . . . . . .
Space Sensors
29
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Economizer Controls
29
. . . . . . . . . . . . . . . . . . . . . . . .
Outdoor Air Enthalpy Control
29
. . . . . . . . . . . . . . .
Differential Enthalpy Control
29
. . . . . . . . . . . . . . . .
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Carrier 50HCQA
Summary
2 Return Air Enthalpy Sensor 29 . . . . . . . . . . . . . . . . . Indoor Air Quality (CO 2 sensor) 30 . . . . . . . . . . . . . Outdoor Air Quality Sensor 30 . . . . . . . . . . . . . . . . . Connecting Discrete Inputs 30 . . . . . . . . . . . . . . . . . . Communication Wiring -- Protocols 31 . . ....
4 C10231 Fig. 1 -- Unit Dimensional Drawing – 04 — 06 Size Unit (cont.) INSTALLATION Jobsite Survey Complete the following checks before installation. 1. Consult local building codes and the NEC (National Electrical Code) ANSI/NFPA 70 for special installa- tion requirements. 2. Determine unit locati...
5 Roof Mount — Check building codes for weight distribution requirements. Unit operating weight is shown in Table 1. Step 2 — Plan for Sequence of Unit Installation The support method used for this unit will dictate different sequences for the steps of unit installation. For example, on curb--mounte...