SUBMITTED TO

COMPANY:

DRAWN BY:
JOB NAME:
EQUIPMENT:

NOTES:

DATE:

01 / 05

Part Number:

MicroMetl

THIS DOCUMENT IS THE PROPERTY OF MICRO METL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICRO METL'S WRITTEN CONSENT.
MANUFACTURER RESERVES THE RIGHT TO DISCONTINUE, OR CHANGE AT ANYTIME, SPECIFICATIONS & DESIGNS WITHOUT ANY NOTICE AND WITHOUT INCURING OBLIGATIONS. COPYRIGHT MICROMETL CORPORATION 2014. ALL RIGHTS RESERVED.

MICROMETL CORPORATION • 3035 N. SHADELAND AVENUE, SUITE 300 • INDIANAPOLIS, IN. 46226 • 1-800-662-4822 ••• MICROMETL WEST • 905 SOUTHERN WAY. • SPARKS, NV 89431 • 1-800-884-4662

S U B M I T T A L

Califor nia and

ASHRAE

Code Compliant

Ultra Low Leak

Down Discharge Economizer

with Relief Capability and

Honeywell Jade

Controls

for Single, 2, or 3 Speed Electromechanical

Carrier Small Rooftop Units Chassis 5,

48/50 TC 16, 50 TCQ 14, 48/50 HC 14,

50 HCQ 12, 48/50 LC 08, 09, 12

FORM NO. ECD-SRT05TA-2W1

M. M.

PL6 Harness

ECD-SRT05TA- Series

Side View

Direct coupled

actuator

External, gear driven

dampers

05/14

Economizers meet Title 24, 2013, Mandatory Section 120.2 Economizer fault and detection diagnostic requirements,
when supplied with controls..

Economizers meet Title 24, 2013, Prescriptive Section 140.4(e)4(A, B, C, and H), D, E, F, and G when supplied with controls,
and ASHRAE Standard 90.1-2010, Table 6.4.3.4.4 requirements.
5 year parts and components warranty. Damper life cycle testing and leakage. Relief. Sensor setpoint, reliability, calibration, and high limit.

Mixed air sensor.

Field installed in mixed

air section.

Outside air sensor

Economizer 93 lbs., Hood 46 lbs.,

Total 139 lbs.

Stainless steel blade

side seal on return and

outside air blades.

26.6"

Honeywell Jade Logic.

Field installed in control

compartment.

Packing tape.

To be removed prior to

installation.

FEATURES:

For single, 2, or 3 speed indoor fan units, as listed above.

External gear driven dampers, eliminate slippage associated
with standard linkage.

Designed specifi cally for down discharge applications. Easy to
install. Easy to service.

Factory assembled rainhood with aluminum water entrainment-
fi lters in the outside portion of the hood.

Uses fi lter access door shipped with HVAC unit.

Hinged fi lter access door is ordered seperately. Contact MMC.

Rainhoods are sloped for water run-off.

Jade W7220 economizer control, Certifi ed FDD Product
California Title 24, Part 6

HJW10

Series

-D2DH

Honeywell communicating actuator w/

adjustable dry bulb controls.

-D2EH

Honeywell communicating actuator w/

enthalpy controls.

-D2XH

Honeywell communicating actuator w/

differential adjustable dry bulb controls.

-D2ZH

Honeywell communicating actuator w/

differential enthalpy controls.

-D00H

Honeywell actuator only w/feedback,

non communicating.