Carrier 48TF004-007 - Manual

Carrier 48TF004-007

Carrier 48TF004-007 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
Page: / 52

Table of Contents:

  • Page 2 – Fig. 1 — Horizontal Conversion Panels
  • Page 3 – Fig. 2 — Roof Curb Dimensions
  • Page 4 – MAXIMUM ALLOWABLE; Fig. 3 — Unit Leveling Tolerances; Fig. 5 — Rigging Details
  • Page 5 – Scroll
  • Page 7 – Fig. 6 — Base Unit Dimensions
  • Page 8 – Step 7 — Make Electrical Connections; Fig. 8 — Gas Piping Guide (With Accessory; STEEL PIPE; Fig. 7 — Flue Hood Details
  • Page 9 – Fig. 9 — Power Wiring Connections; Fig. 11 — Field Control Wiring Raceway
  • Page 10 – Table 2 — Electrical Data
  • Page 13 – Enthalpy Control Installation
  • Page 14 – OAT — Outdoor-Air Thermostat; NOTE: See unit wiring diagram for details.
  • Page 15 – Fig. 29 — Completed Hood Assembly
  • Page 16 – OAT
  • Page 17 – OR; Fig. 34 — Wiring Diagram for Power Exhaust System
  • Page 18 – Fig. 38 — Barometric Relief Capacity
  • Page 19 – Step 9 — Adjust Evaporator-Fan Speed —; Set movable flange at nearest keyway of pulley hub and; Fig. 40 — Belt Drive Motor Mounting
  • Page 36 – Table 30 — Altitude Compensation*; *As the height above sea level increases, there is less oxygen per
  • Page 38 – Fig. 42 — Cleaning Condenser Coil
  • Page 39 – Fig. 44 — Separating Coil Sections
  • Page 40 – SUCTION LINE PRESSURE (KILOP; SUCTION LINE PRESSURE (KILOP
  • Page 41 – TON UNIT CHARGING CHART
  • Page 42 – Table 31 — LED Error Code Description; Main Burners —; Fig. 50 — Burner Section Details
  • Page 43 – LOW HEAT
  • Page 44 – TROUBLESHOOTING; Table 32 — LED Error Code Service Analysis
  • Page 45 – Table 34 — Cooling Service Analysis
  • Page 46 – Table 35 — Durablade Economizer Troubleshooting
  • Page 47 – Table 36 — EconoMi$er Troubleshooting; OAT — Outdoor-Air Temperature
  • Page 48 – Fig. 53 — Typical Wiring Diagram and Component Arrangement
  • Page 52 – ELECTRICAL
Loading the manual

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

PC 111

Catalog No. 534-80000

Printed in U.S.A.

Form 48TF-1SI

Pg 1

8-00

Replaces: New

Book 1

4

Tab

1a 6a

Installation, Start-Up, and

Service Instructions

CONTENTS

Page

SAFETY CONSIDERATIONS

. . . . . . . . . . . . . . . . . . . . . . 1

INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-35

Step 1 — Provide Unit Support

. . . . . . . . . . . . . . . . . . . 1

• ROOF CURB
• SLAB MOUNT

Step 2 — Field Fabricate Ductwork

. . . . . . . . . . . . . . . 2

Step 3 — Install External Trap for Condensate

Drain

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Step 4 — Rig and Place Unit

. . . . . . . . . . . . . . . . . . . . . 2

• POSITIONING

Step 5 — Install Flue Hood

. . . . . . . . . . . . . . . . . . . . . . . 4

Step 6 — Install Gas Piping

. . . . . . . . . . . . . . . . . . . . . . 4

Step 7 — Make Electrical Connections

. . . . . . . . . . . 8

• FIELD POWER SUPPLY
• FIELD CONTROL WIRING
• HEAT ANTICIPATOR SETTINGS

Step 8 — Make Outdoor-Air Adjustments

and Install Outdoor-Air Hood

. . . . . . . . . . . . . . . . . . 11

• MANUAL OUTDOOR-AIR DAMPER
• OPTIONAL DURABLADE ECONOMIZER
• OPTIONAL ECONOMI$ER

Step 9 — Adjust Evaporator-Fan Speed

. . . . . . . . . 19

• DIRECT-DRIVE MOTORS
• BELT-DRIVE MOTORS

START-UP

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-38

SERVICE

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-43

TROUBLESHOOTING

. . . . . . . . . . . . . . . . . . . . . . . . . 44-49

START-UP CHECKLIST

. . . . . . . . . . . . . . . . . . . . . . . . CL-1

SAFETY CONSIDERATIONS

Installation and servicing of air-conditioning equipment can

be hazardous due to system pressure and electrical compo-
nents. Only trained and qualified service personnel should
install, repair, or service air-conditioning equipment.

Untrained personnel can perform basic maintenance func-

tions of cleaning coils and filters and replacing filters. All other
operations should be performed by trained service personnel.
When working on air-conditioning equipment, observe precau-
tions in the literature, tags and labels attached to the unit, and
other safety precautions that apply.

Follow all safety codes. Wear safety glasses and work

gloves. Use quenching cloth for unbrazing operations. Have
fire extinguishers available for all brazing operations.

INSTALLATION

Unit is shipped in the vertical duct configuration. To convert

to horizontal configuration, remove screws from side duct
opening covers and remove covers. Using the same screws, in-
stall covers on vertical duct openings with the insulation-side
down. Seals around duct openings must be tight. See Fig. 1.

Confirm before installation of unit that voltage, amperage

and circuit protection requirements listed on unit data plate
agree with power supply provided.

Step 1 — Provide Unit Support

ROOF CURB — Assemble and install accessory roof curb in
accordance with instructions shipped with curb. See Fig. 2. In-
stall insulation, cant strips, roofing felt, and counter flashing as
shown. Ductwork must be attached to curb, not to the unit. The
accessory thru-the-bottom power and gas connection package
must be installed before the unit is set on the roof curb.
If field-
installed (thru-the-roof curb) gas connections are desired, use
factory-supplied

3

/

4

-in. pipe coupling and gas plate assembly to

mount the thru-the-roof curb connection to the roof curb. Gas
connections and power connections to the unit must be field in-
stalled after the unit is installed on the roof curb.

If electric and control wiring is to be routed through the

basepan, attach the accessory thru-the-bottom service connec-
tions to the basepan in accordance with the accessory installa-
tion instructions.

Disconnect gas piping from unit when leak
testing at pressure greater than

1

/

2

psig.

Pressures greater than

1

/

2

psig will cause

gas valve damage resulting in hazardous
condition. If gas valve is subjected to pres-
sure greater than

1

/

2

psig, it must be

replaced before use. When pressure testing
field-supplied gas piping at pressures of

1

/

2

psig or less, a unit connected to such

piping must be isolated by manually closing
the gas valve.

Before performing service or maintenance operations on
unit, turn off main power switch to unit and install a lock-
out tag. Electrical shock could cause personal injury.

IMPORTANT: The gasketing of the unit to the roof curb
is critical for a watertight seal. Install gasket supplied
with the roof curb as shown in Fig. 2. Improperly
applied gasket can result in air leaks and poor unit
performance.

48TF004-007

Single-Package Rooftop

Heating/Cooling Units

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Fig. 1 — Horizontal Conversion Panels

2 Curb should be level. Unit leveling tolerances are shown in Fig. 3. This is necessary for unit drain to function properly. Re-fer to Accessory Roof Curb Installation Instructions for addi-tional information as required.SLAB MOUNT (Horizontal Units Only) — Provide a levelconcrete slab that extends ...

Page 3 - Fig. 2 — Roof Curb Dimensions

3 Fig. 2 — Roof Curb Dimensions ROOF CURB ACCESSORY A UNIT SIZE CRRFCURB001A00 1 ′ -2 ″ [356] 48TF004-007 CRRFCURB002A00 2 ′ -0 ″ [610] NOTES:1. Roof curb accessory is shipped disassembled.2. Insulated panels.3. Dimensions in [ ] are in millimeters. 4. Roof curb, galvanized steel.5. Attach ductwork ...

Page 4 - MAXIMUM ALLOWABLE; Fig. 3 — Unit Leveling Tolerances; Fig. 5 — Rigging Details

4 Unit may be installed directly on wood flooring or on Class A, B, or C roof-covering material when roof curb is used. Although unit is weatherproof, guard against water from higher level runoff and overhangs. Flue vent discharge must have a minimum horizontal clear- ance of 4 ft from electric and ...

Other Carrier Models