Carrier 48TF004-007 - Manual
Carrier 48TF004-007 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Fig. 1 — Horizontal Conversion Panels
- Page 3 – Fig. 2 — Roof Curb Dimensions
- Page 4 – MAXIMUM ALLOWABLE; Fig. 3 — Unit Leveling Tolerances; Fig. 5 — Rigging Details
- Page 5 – Scroll
- Page 7 – Fig. 6 — Base Unit Dimensions
- Page 8 – Step 7 — Make Electrical Connections; Fig. 8 — Gas Piping Guide (With Accessory; STEEL PIPE; Fig. 7 — Flue Hood Details
- Page 9 – Fig. 9 — Power Wiring Connections; Fig. 11 — Field Control Wiring Raceway
- Page 10 – Table 2 — Electrical Data
- Page 13 – Enthalpy Control Installation
- Page 14 – OAT — Outdoor-Air Thermostat; NOTE: See unit wiring diagram for details.
- Page 15 – Fig. 29 — Completed Hood Assembly
- Page 16 – OAT
- Page 17 – OR; Fig. 34 — Wiring Diagram for Power Exhaust System
- Page 18 – Fig. 38 — Barometric Relief Capacity
- Page 19 – Step 9 — Adjust Evaporator-Fan Speed —; Set movable flange at nearest keyway of pulley hub and; Fig. 40 — Belt Drive Motor Mounting
- Page 36 – Table 30 — Altitude Compensation*; *As the height above sea level increases, there is less oxygen per
- Page 38 – Fig. 42 — Cleaning Condenser Coil
- Page 39 – Fig. 44 — Separating Coil Sections
- Page 40 – SUCTION LINE PRESSURE (KILOP; SUCTION LINE PRESSURE (KILOP
- Page 41 – TON UNIT CHARGING CHART
- Page 42 – Table 31 — LED Error Code Description; Main Burners —; Fig. 50 — Burner Section Details
- Page 43 – LOW HEAT
- Page 44 – TROUBLESHOOTING; Table 32 — LED Error Code Service Analysis
- Page 45 – Table 34 — Cooling Service Analysis
- Page 46 – Table 35 — Durablade Economizer Troubleshooting
- Page 47 – Table 36 — EconoMi$er Troubleshooting; OAT — Outdoor-Air Temperature
- Page 48 – Fig. 53 — Typical Wiring Diagram and Component Arrangement
- Page 52 – ELECTRICAL
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
PC 111
Catalog No. 534-80000
Printed in U.S.A.
Form 48TF-1SI
Pg 1
8-00
Replaces: New
Book 1
4
Tab
1a 6a
Installation, Start-Up, and
Service Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS
. . . . . . . . . . . . . . . . . . . . . . 1
INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-35
Step 1 — Provide Unit Support
. . . . . . . . . . . . . . . . . . . 1
• ROOF CURB
• SLAB MOUNT
Step 2 — Field Fabricate Ductwork
. . . . . . . . . . . . . . . 2
Step 3 — Install External Trap for Condensate
Drain
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Step 4 — Rig and Place Unit
. . . . . . . . . . . . . . . . . . . . . 2
• POSITIONING
Step 5 — Install Flue Hood
. . . . . . . . . . . . . . . . . . . . . . . 4
Step 6 — Install Gas Piping
. . . . . . . . . . . . . . . . . . . . . . 4
Step 7 — Make Electrical Connections
. . . . . . . . . . . 8
• FIELD POWER SUPPLY
• FIELD CONTROL WIRING
• HEAT ANTICIPATOR SETTINGS
Step 8 — Make Outdoor-Air Adjustments
and Install Outdoor-Air Hood
. . . . . . . . . . . . . . . . . . 11
• MANUAL OUTDOOR-AIR DAMPER
• OPTIONAL DURABLADE ECONOMIZER
• OPTIONAL ECONOMI$ER
Step 9 — Adjust Evaporator-Fan Speed
. . . . . . . . . 19
• DIRECT-DRIVE MOTORS
• BELT-DRIVE MOTORS
START-UP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-38
SERVICE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-43
TROUBLESHOOTING
. . . . . . . . . . . . . . . . . . . . . . . . . 44-49
START-UP CHECKLIST
. . . . . . . . . . . . . . . . . . . . . . . . CL-1
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can
be hazardous due to system pressure and electrical compo-
nents. Only trained and qualified service personnel should
install, repair, or service air-conditioning equipment.
Untrained personnel can perform basic maintenance func-
tions of cleaning coils and filters and replacing filters. All other
operations should be performed by trained service personnel.
When working on air-conditioning equipment, observe precau-
tions in the literature, tags and labels attached to the unit, and
other safety precautions that apply.
Follow all safety codes. Wear safety glasses and work
gloves. Use quenching cloth for unbrazing operations. Have
fire extinguishers available for all brazing operations.
INSTALLATION
Unit is shipped in the vertical duct configuration. To convert
to horizontal configuration, remove screws from side duct
opening covers and remove covers. Using the same screws, in-
stall covers on vertical duct openings with the insulation-side
down. Seals around duct openings must be tight. See Fig. 1.
Confirm before installation of unit that voltage, amperage
and circuit protection requirements listed on unit data plate
agree with power supply provided.
Step 1 — Provide Unit Support
ROOF CURB — Assemble and install accessory roof curb in
accordance with instructions shipped with curb. See Fig. 2. In-
stall insulation, cant strips, roofing felt, and counter flashing as
shown. Ductwork must be attached to curb, not to the unit. The
accessory thru-the-bottom power and gas connection package
must be installed before the unit is set on the roof curb. If field-
installed (thru-the-roof curb) gas connections are desired, use
factory-supplied
3
/
4
-in. pipe coupling and gas plate assembly to
mount the thru-the-roof curb connection to the roof curb. Gas
connections and power connections to the unit must be field in-
stalled after the unit is installed on the roof curb.
If electric and control wiring is to be routed through the
basepan, attach the accessory thru-the-bottom service connec-
tions to the basepan in accordance with the accessory installa-
tion instructions.
Disconnect gas piping from unit when leak
testing at pressure greater than
1
/
2
psig.
Pressures greater than
1
/
2
psig will cause
gas valve damage resulting in hazardous
condition. If gas valve is subjected to pres-
sure greater than
1
/
2
psig, it must be
replaced before use. When pressure testing
field-supplied gas piping at pressures of
1
/
2
psig or less, a unit connected to such
piping must be isolated by manually closing
the gas valve.
Before performing service or maintenance operations on
unit, turn off main power switch to unit and install a lock-
out tag. Electrical shock could cause personal injury.
IMPORTANT: The gasketing of the unit to the roof curb
is critical for a watertight seal. Install gasket supplied
with the roof curb as shown in Fig. 2. Improperly
applied gasket can result in air leaks and poor unit
performance.
48TF004-007
Single-Package Rooftop
Heating/Cooling Units
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 Curb should be level. Unit leveling tolerances are shown in Fig. 3. This is necessary for unit drain to function properly. Re-fer to Accessory Roof Curb Installation Instructions for addi-tional information as required.SLAB MOUNT (Horizontal Units Only) — Provide a levelconcrete slab that extends ...
3 Fig. 2 — Roof Curb Dimensions ROOF CURB ACCESSORY A UNIT SIZE CRRFCURB001A00 1 ′ -2 ″ [356] 48TF004-007 CRRFCURB002A00 2 ′ -0 ″ [610] NOTES:1. Roof curb accessory is shipped disassembled.2. Insulated panels.3. Dimensions in [ ] are in millimeters. 4. Roof curb, galvanized steel.5. Attach ductwork ...
4 Unit may be installed directly on wood flooring or on Class A, B, or C roof-covering material when roof curb is used. Although unit is weatherproof, guard against water from higher level runoff and overhangs. Flue vent discharge must have a minimum horizontal clear- ance of 4 ft from electric and ...