Carrier 48MA/50ME016-040- User Manual

Carrier 48MA/50ME016-040

Carrier 48MA/50ME016-040– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
Page: / 48

Table of Contents:

  • Page 3 – Fig. 1 — Base Unit Physical Data and Dimensions 48MA Units
  • Page 4 – Fig. 2 — Base Unit Physical Data and Dimensions 50ME Units
  • Page 5 – Fig. 3 — Roof Curb Detail
  • Page 6 – Table 1 — Physical Data
  • Page 7 – Fig. 4 — Roof Curb Physical Data and Dimensions 48MA Units
  • Page 8 – Fig. 5 — Roof Curb Physical Data and Dimensions 50ME Units
  • Page 9 – Condensate Drains —; Fig. 6 — Shipping Shield Locations; Fig. 7 — Field-Fabricated Zone Duct Plenum Detail
  • Page 10 – Field Power Supply Wiring —; — Ground; Fig. 9 — Field Power Supply Details
  • Page 11 – Table 2 — Unit 48MA Electrical Data
  • Page 12 – Table 3 — Unit 50ME Electrical Data; Table 4 — Electric Resistance Heater Data
  • Page 13 – Table 5 — Unit 50ME Electrical Application Data
  • Page 14 – Field Control Wiring; Fig. 10 — Zone Control Board Component Location
  • Page 34 – Fig. 29 — Remote Control Panel Accessory Connections
  • Page 35 – Fig. 30 — Humidistat Connections
  • Page 37 – Fig. 33 — Spoiler Screw Location
  • Page 40 – Fig. 36 — Compressor Capacity Control
  • Page 41 – Condenser Fans; Reverse this procedure for reassembly.; Evaporator Fans and Motor; move the fan drive pulley.; Fig. 37 — Motormaster
  • Page 42 – Zone Module Transformers —; When replacing these; Optional Economizer —; OPERATION; Optional Exhaust Damper —; When the return air damper is 25% closed, the exhaust; Replacement Parts —; A complete list of replacement; Shutter Position
  • Page 43 – Fig. 40 — Economizer and Exhaust Damper Assemblies, Exploded View
  • Page 46 – PACKAGED SERVICE TRAINING
Loading the manual

Installation, Start-Up

and Service Instructions

CONTENTS

Page

SAFETY CONSIDERATIONS

. . . . . . . . . . . . . . . . . . . 2

INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-34

General

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Unit Clearances

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Roof Curb

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Roof Openings

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Rigging Unit

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Unit Positioning

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Removing Shipping Shields

. . . . . . . . . . . . . . . . . . 5

Field-Fabricated Ductwork

. . . . . . . . . . . . . . . . . . . . 5

Condensate Drains

. . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Gas Piping (48MA)

. . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Optional Glycol Connections (50ME)

. . . . . . . . . 10

Field Power Supply Wiring

. . . . . . . . . . . . . . . . . . 10

• UNIT COMMON FEED MINIMUM CIRCUIT AMPS

Field Control Wiring

. . . . . . . . . . . . . . . . . . . . . . . . . 14

• ZONE THERMOSTATS
• ZONE MODULE CONNECTIONS
• ACCESSORY REMOTE CONTROL PANEL

Reheat Humidity Control

. . . . . . . . . . . . . . . . . . . . 34

Optional Economizer

. . . . . . . . . . . . . . . . . . . . . . . . 34

Optional Exhaust Damper

. . . . . . . . . . . . . . . . . . . 34

START-UP

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-39

Evaporator Fan

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Compressor Rail Shipping Bolts

. . . . . . . . . . . . . 34

Refrigerant Valves

. . . . . . . . . . . . . . . . . . . . . . . . . . 34

Zone Module Gas Valves (48MA)

. . . . . . . . . . . . . 34

Gas Heat Lighting Procedure (48MA)

. . . . . . . . . 35

• TO SHUT OFF GAS HEAT

Intermittant Pilots (48MA)

. . . . . . . . . . . . . . . . . . . 35

• ADJUSTMENT
• PRESSURE ADJUSTMENT (NATURAL GAS)

Main Burner Adjustment (48MA)

. . . . . . . . . . . . . 36

• ORIFICE ALIGNMENT
• PRIMARY AIR ADJUSTMENT

Outdoor-Air Thermostat Adjustment

(50ME With Electric Heat)

. . . . . . . . . . . . . . . . . . 36

• UNITS WITH 2-ELEMENT HEATERS
• UNITS WITH 3-ELEMENT HEATERS

Optional Glycol Heating Coils

. . . . . . . . . . . . . . . . 38

Zone Airflow Adjustment

. . . . . . . . . . . . . . . . . . . . 38

Sequence of Operation

. . . . . . . . . . . . . . . . . . . . . 38

• COOLING
• HEATING (48MA)
• HEATING (50ME WITH ELECTRIC HEAT)
• HEATING (50ME WITH GLYCOL HEATING COILS)
• OUTDOOR-AIR DAMPER

SERVICE

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39-43

Cabinet Panels and Grilles

. . . . . . . . . . . . . . . . . . 39

• SIDE PANELS
• TOP PANELS
• HEATER ACCESS PANELS

Cleaning

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

• EVAPORATOR COILS (ZONE COOLING COILS)

AND GLYCOL HEATING COILS

• CONDENSER AND OUTDOOR-AIR COOLING

COILS

• CONDENSATE DRAINS
• INDOOR-AIR FILTERS
• OUTDOOR-AIR INLET SCREENS
• GAS HEATING SECTION
• COMBUSTION AIR FAN

Airflow Switches

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

• INDOOR AIRFLOW SWITCH (AFS1)
• COMBUSTION AIRFLOW SWITCH (AFS2)

Service Switch

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Time Guard

T

Control Circuit

. . . . . . . . . . . . . . . . . 39

Capacity Control Pressure Switches (CCP)

(2-Compressor Units Only)

. . . . . . . . . . . . . . . . 39

Compressor Oil

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

• TO ADD OR REMOVE OIL

Compressor Capacity Control Unloader(s)

. . . . 40

• CONTROL SET POINT
• PRESSURE DIFFERENTIAL

Crankcase Heater(s)

. . . . . . . . . . . . . . . . . . . . . . . . . 40

Refrigerant Charge

. . . . . . . . . . . . . . . . . . . . . . . . . . 40

• NO CHARGE
• LOW CHARGE

Head Pressure Control

. . . . . . . . . . . . . . . . . . . . . . 40

• MOTORMASTER

t

HEAD PRESSURE CONTROL

DEVICE

• FAN CYCLING PRESSURESTAT

Condenser Fans

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

• ADJUSTMENT
• FAN MOTOR REMOVAL
• LUBRICATION

Evaporator Fans and Motor

. . . . . . . . . . . . . . . . . . 41

• MOTOR REMOVAL
• FAN SHAFT BEARING REMOVAL
• FAN SPEED ADJUSTMENT
• PULLEY REMOVAL
• PULLEY ALIGNMENT
• BELT TENSION ADJUSTMENT
• LUBRICATION

Forced-Draft Blower (48MA)

. . . . . . . . . . . . . . . . . 42

• LUBRICATION
• AIR SHUTTER ADJUSTMENT

Zone Module Transformers

. . . . . . . . . . . . . . . . . . 42

Optional Economizer

. . . . . . . . . . . . . . . . . . . . . . . . 42

• THERMOSTAT SETTINGS
• DAMPER POSITION
• OPERATION

Optional Exhaust Damper

. . . . . . . . . . . . . . . . . . . 42

Replacement Parts

. . . . . . . . . . . . . . . . . . . . . . . . . . 42

START-UP CHECKLIST

. . . . . . . . . . . . . . . . . . . . . CL-1

48MA/50ME016-040

Combination Multizone Heating/Cooling Units

Gas, Electric, or Glycol Heat

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book 1

1

Tab

1c 1d

PC 111

Catalog No. 564-840

Printed in U.S.A.

Form 48MA/50ME-3SI

Pg 1

4-96

Replaces: 48MA/50ME-1SI

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Carrier 48MA/50ME016-040

Summary

Page 3 - Fig. 1 — Base Unit Physical Data and Dimensions 48MA Units

CONDENSER SECTION AIRFLOW CONN — Connection NOTES:1. Space required for service and airflow all around and above unit is 36 inches. 2. For additional information see Fig. 4.3. Center of gravity is within 6 in. radius of geo- metric center of unit. 4. Maximum allowable pitch of unit is 1 ⁄ 2 in. per ...

Page 4 - Fig. 2 — Base Unit Physical Data and Dimensions 50ME Units

CONDENSER SECTION AIRFLOW CONN — Connection NOTES:1. Space required for service and airflow all around and above unit is 36 inches. 2. For additional information see Fig. 5.3. Center of gravity is within 6 in. radius of geo- metric center of unit. 4. Maximum allowable pitch of unit is 1 ⁄ 2 in. per ...

Page 5 - Fig. 3 — Roof Curb Detail

Rigging Unit — Inspect unit for shipping damage, and file any damage claim immediately with transportationcompany. Lift unit with cables and spreader bars, using lifting brack- ets provided (Fig. 1 and 2). Lift one unit at a time, keep unitupright, and do not drop. Unit weights are given in Table 1....

Other Carrier Models