Carrier 48MA/50ME016-040- User Manual
Carrier 48MA/50ME016-040– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – Fig. 1 — Base Unit Physical Data and Dimensions 48MA Units
- Page 4 – Fig. 2 — Base Unit Physical Data and Dimensions 50ME Units
- Page 5 – Fig. 3 — Roof Curb Detail
- Page 6 – Table 1 — Physical Data
- Page 7 – Fig. 4 — Roof Curb Physical Data and Dimensions 48MA Units
- Page 8 – Fig. 5 — Roof Curb Physical Data and Dimensions 50ME Units
- Page 9 – Condensate Drains —; Fig. 6 — Shipping Shield Locations; Fig. 7 — Field-Fabricated Zone Duct Plenum Detail
- Page 10 – Field Power Supply Wiring —; — Ground; Fig. 9 — Field Power Supply Details
- Page 11 – Table 2 — Unit 48MA Electrical Data
- Page 12 – Table 3 — Unit 50ME Electrical Data; Table 4 — Electric Resistance Heater Data
- Page 13 – Table 5 — Unit 50ME Electrical Application Data
- Page 14 – Field Control Wiring; Fig. 10 — Zone Control Board Component Location
- Page 34 – Fig. 29 — Remote Control Panel Accessory Connections
- Page 35 – Fig. 30 — Humidistat Connections
- Page 37 – Fig. 33 — Spoiler Screw Location
- Page 40 – Fig. 36 — Compressor Capacity Control
- Page 41 – Condenser Fans; Reverse this procedure for reassembly.; Evaporator Fans and Motor; move the fan drive pulley.; Fig. 37 — Motormaster
- Page 42 – Zone Module Transformers —; When replacing these; Optional Economizer —; OPERATION; Optional Exhaust Damper —; When the return air damper is 25% closed, the exhaust; Replacement Parts —; A complete list of replacement; Shutter Position
- Page 43 – Fig. 40 — Economizer and Exhaust Damper Assemblies, Exploded View
- Page 46 – PACKAGED SERVICE TRAINING
Installation, Start-Up
and Service Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS
. . . . . . . . . . . . . . . . . . . 2
INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-34
General
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Unit Clearances
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Roof Curb
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Roof Openings
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Rigging Unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Unit Positioning
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Removing Shipping Shields
. . . . . . . . . . . . . . . . . . 5
Field-Fabricated Ductwork
. . . . . . . . . . . . . . . . . . . . 5
Condensate Drains
. . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Gas Piping (48MA)
. . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Optional Glycol Connections (50ME)
. . . . . . . . . 10
Field Power Supply Wiring
. . . . . . . . . . . . . . . . . . 10
• UNIT COMMON FEED MINIMUM CIRCUIT AMPS
Field Control Wiring
. . . . . . . . . . . . . . . . . . . . . . . . . 14
• ZONE THERMOSTATS
• ZONE MODULE CONNECTIONS
• ACCESSORY REMOTE CONTROL PANEL
Reheat Humidity Control
. . . . . . . . . . . . . . . . . . . . 34
Optional Economizer
. . . . . . . . . . . . . . . . . . . . . . . . 34
Optional Exhaust Damper
. . . . . . . . . . . . . . . . . . . 34
START-UP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-39
Evaporator Fan
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Compressor Rail Shipping Bolts
. . . . . . . . . . . . . 34
Refrigerant Valves
. . . . . . . . . . . . . . . . . . . . . . . . . . 34
Zone Module Gas Valves (48MA)
. . . . . . . . . . . . . 34
Gas Heat Lighting Procedure (48MA)
. . . . . . . . . 35
• TO SHUT OFF GAS HEAT
Intermittant Pilots (48MA)
. . . . . . . . . . . . . . . . . . . 35
• ADJUSTMENT
• PRESSURE ADJUSTMENT (NATURAL GAS)
Main Burner Adjustment (48MA)
. . . . . . . . . . . . . 36
• ORIFICE ALIGNMENT
• PRIMARY AIR ADJUSTMENT
Outdoor-Air Thermostat Adjustment
(50ME With Electric Heat)
. . . . . . . . . . . . . . . . . . 36
• UNITS WITH 2-ELEMENT HEATERS
• UNITS WITH 3-ELEMENT HEATERS
Optional Glycol Heating Coils
. . . . . . . . . . . . . . . . 38
Zone Airflow Adjustment
. . . . . . . . . . . . . . . . . . . . 38
Sequence of Operation
. . . . . . . . . . . . . . . . . . . . . 38
• COOLING
• HEATING (48MA)
• HEATING (50ME WITH ELECTRIC HEAT)
• HEATING (50ME WITH GLYCOL HEATING COILS)
• OUTDOOR-AIR DAMPER
SERVICE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39-43
Cabinet Panels and Grilles
. . . . . . . . . . . . . . . . . . 39
• SIDE PANELS
• TOP PANELS
• HEATER ACCESS PANELS
Cleaning
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
• EVAPORATOR COILS (ZONE COOLING COILS)
AND GLYCOL HEATING COILS
• CONDENSER AND OUTDOOR-AIR COOLING
COILS
• CONDENSATE DRAINS
• INDOOR-AIR FILTERS
• OUTDOOR-AIR INLET SCREENS
• GAS HEATING SECTION
• COMBUSTION AIR FAN
Airflow Switches
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
• INDOOR AIRFLOW SWITCH (AFS1)
• COMBUSTION AIRFLOW SWITCH (AFS2)
Service Switch
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Time Guard
T
Control Circuit
. . . . . . . . . . . . . . . . . 39
Capacity Control Pressure Switches (CCP)
(2-Compressor Units Only)
. . . . . . . . . . . . . . . . 39
Compressor Oil
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
• TO ADD OR REMOVE OIL
Compressor Capacity Control Unloader(s)
. . . . 40
• CONTROL SET POINT
• PRESSURE DIFFERENTIAL
Crankcase Heater(s)
. . . . . . . . . . . . . . . . . . . . . . . . . 40
Refrigerant Charge
. . . . . . . . . . . . . . . . . . . . . . . . . . 40
• NO CHARGE
• LOW CHARGE
Head Pressure Control
. . . . . . . . . . . . . . . . . . . . . . 40
• MOTORMASTER
t
HEAD PRESSURE CONTROL
DEVICE
• FAN CYCLING PRESSURESTAT
Condenser Fans
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
• ADJUSTMENT
• FAN MOTOR REMOVAL
• LUBRICATION
Evaporator Fans and Motor
. . . . . . . . . . . . . . . . . . 41
• MOTOR REMOVAL
• FAN SHAFT BEARING REMOVAL
• FAN SPEED ADJUSTMENT
• PULLEY REMOVAL
• PULLEY ALIGNMENT
• BELT TENSION ADJUSTMENT
• LUBRICATION
Forced-Draft Blower (48MA)
. . . . . . . . . . . . . . . . . 42
• LUBRICATION
• AIR SHUTTER ADJUSTMENT
Zone Module Transformers
. . . . . . . . . . . . . . . . . . 42
Optional Economizer
. . . . . . . . . . . . . . . . . . . . . . . . 42
• THERMOSTAT SETTINGS
• DAMPER POSITION
• OPERATION
Optional Exhaust Damper
. . . . . . . . . . . . . . . . . . . 42
Replacement Parts
. . . . . . . . . . . . . . . . . . . . . . . . . . 42
START-UP CHECKLIST
. . . . . . . . . . . . . . . . . . . . . CL-1
48MA/50ME016-040
Combination Multizone Heating/Cooling Units
Gas, Electric, or Glycol Heat
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1
1
Tab
1c 1d
PC 111
Catalog No. 564-840
Printed in U.S.A.
Form 48MA/50ME-3SI
Pg 1
4-96
Replaces: 48MA/50ME-1SI
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Carrier 48MA/50ME016-040
Summary
CONDENSER SECTION AIRFLOW CONN — Connection NOTES:1. Space required for service and airflow all around and above unit is 36 inches. 2. For additional information see Fig. 4.3. Center of gravity is within 6 in. radius of geo- metric center of unit. 4. Maximum allowable pitch of unit is 1 ⁄ 2 in. per ...
CONDENSER SECTION AIRFLOW CONN — Connection NOTES:1. Space required for service and airflow all around and above unit is 36 inches. 2. For additional information see Fig. 5.3. Center of gravity is within 6 in. radius of geo- metric center of unit. 4. Maximum allowable pitch of unit is 1 ⁄ 2 in. per ...
Rigging Unit — Inspect unit for shipping damage, and file any damage claim immediately with transportationcompany. Lift unit with cables and spreader bars, using lifting brack- ets provided (Fig. 1 and 2). Lift one unit at a time, keep unitupright, and do not drop. Unit weights are given in Table 1....