Carrier 48HX- User Manual

Carrier 48HX

Carrier 48HX– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 2 – ELECTRIC HEAT POWER DIAGRAMS; PLUG LOCATION REFERENCE
  • Page 4 – Gas Heat Unit Operation —
  • Page 6 – INPUT/OUTPUT CHANNEL DESIGNATIONS — STAGED GAS HEAT CONTROL BOARD
  • Page 7 – INPUT/OUTPUT CHANNEL DESIGNATIONS — CONTROLS EXPANSION BOARD
  • Page 14 – PAGE
  • Page 24 – Fig. 18 — Space Temperature Averaging Wiring
  • Page 25 – Fig. 19 — Electric Heater Power Diagrams
Loading the manual

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Catalog No. 04-56480002-01

Printed in U.S.A.

Form 48/50A-3W

Pg 1 508 4-08

Replaces: New

Wiring Diagrams

INDEX

ACCESSORIES

NOTE: Accessory wiring is shown on the unit wiring diagrams. Refer
to the appropriate drawing for accessory wiring.

TYPE

UNIT

NUMBER

FIG. NO.

Component Arrangement

48/50A2,A3,A4,A5020-035

48EJ502489

1

48/50A2,A3,A4,A5040-060

48EJ503652

2

Power Schematic

48/50A2,A3,A4,A5020-050

50EJ500470

3

48/50A2,A3,A4,A5060 RTPF

50EJ500469

4

48/50A2,A3,A4,A5060 MCHX

50EJ500420

5

Main Control Box Circuit

48/50A2,A3,A4,A5020-060

50EJ500440

6

Auxiliary Control Box Wiring

48/50A2,A3,A4,A5020-060

48EJ503076

7

Controls Expansion

Board Wiring

48/50A2,A3,A4,A5020-060

48EJ503086

8

Gas Heat Control Circuit

(2-Stage Heat)

48A2,A3,A4,A5020-050

48EJ503079

9

48A2,A3,A4,A5060

48EJ503679

10

Gas Heat Control Circuit

(Staged Gas Heat)

48A2,A3,A4,A5020-050

48EJ502488

11

48A2,A3,A4,A5060

48EJ503680

12

Electric Heat Control Circuit

50A2,A3,A4,A5020-050

48EJ503080

13

50A2,A3,A4,A5060

48EJ503655

14

ACCESSORY

UNIT

FIG. NO.

Motormaster® V Low Ambient Controller

48/50A2,A3,A4,A5020-035

15

48/50A2,A3,A4,A5040,050 AND 060 RTPF Units

16

48/50A2,A3,A4,A5060 MCHX Units

17

Space Sensor Temperature Averaging

48/50A2,A3,A4,A5020-060

18

Thermostat

48/50A2,A3,A4,A5020-060

6

Remote Economizer Position Override
Remote Economizer Minimum Position Set Point
Remote 4 to 20 mA Economizer Position
Space IAQ Sensor
Outdoor Enthalpy Changeover Sensor

48/50A2,A3,A4,A5020-060

7

Differential Enthalpy Changeover Sensor
Outdoor Air Quality Sensor

48/50A2,A3,A4,A5020-060

8

Remote Supply Air Set Point
Demand Limit Controller
Fan Status Switch
Demand Limit
Fire Pressurization
Fire Evacuation
Fire Smoke Purge
IAQ Override Switch

WEATHERMAKER

®

48/50A2,A3,A4,A5020-060

Single Package Rooftop

Gas Heating/Electric Cooling and Electric Cooling Units

with

COMFORT

LINK™ Controls

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - ELECTRIC HEAT POWER DIAGRAMS; PLUG LOCATION REFERENCE

2 ELECTRIC HEAT POWER DIAGRAMS NOTE: All power leads connect to (single) TB7 power terminal block.There are 2 or 3 conductors per terminal. LEGEND AND NOTES FOR FIG. 1-14 UNIT SIZES 50A2,A3,A4,A5 ELECTRICAL CHARACTERISTICS NOMINAL kW FIG. NO. QTY PER UNIT Lo Heat Hi Heat 020-050 208/230-3-60 36 72 1...

Page 4 - Gas Heat Unit Operation —

4 If the control is connected to a ComfortID™ system, the room terminals are equipped with microprocessor controls that give commands to the base module. If linkage is active, the control module will replace local Comfort Link™ set points and occupancy data with linkage supplied data. If Temperature...

Page 6 - INPUT/OUTPUT CHANNEL DESIGNATIONS — STAGED GAS HEAT CONTROL BOARD

6 INPUT/OUTPUT CHANNEL DESIGNATIONS — ECONOMIZER CONTROL BOARD (ECB1) INPUT/OUTPUT CHANNEL DESIGNATIONS — VAV CONTROL BOARD (ECB2) INPUT/OUTPUT CHANNEL DESIGNATIONS — STAGED GAS HEAT CONTROL BOARD POINT NAME POINT DESCRIPTION I/O POINT NAME PLUG AND PIN REFERENCE SIGNAL PIN(S) PORT STATE INPUTS RMTI...

Other Carrier Models