Carrier 48HX- User Manual
Carrier 48HX– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – ELECTRIC HEAT POWER DIAGRAMS; PLUG LOCATION REFERENCE
- Page 4 – Gas Heat Unit Operation —
- Page 6 – INPUT/OUTPUT CHANNEL DESIGNATIONS — STAGED GAS HEAT CONTROL BOARD
- Page 7 – INPUT/OUTPUT CHANNEL DESIGNATIONS — CONTROLS EXPANSION BOARD
- Page 14 – PAGE
- Page 24 – Fig. 18 — Space Temperature Averaging Wiring
- Page 25 – Fig. 19 — Electric Heater Power Diagrams
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-56480002-01
Printed in U.S.A.
Form 48/50A-3W
Pg 1 508 4-08
Replaces: New
Wiring Diagrams
INDEX
ACCESSORIES
NOTE: Accessory wiring is shown on the unit wiring diagrams. Refer
to the appropriate drawing for accessory wiring.
TYPE
UNIT
NUMBER
FIG. NO.
Component Arrangement
48/50A2,A3,A4,A5020-035
48EJ502489
1
48/50A2,A3,A4,A5040-060
48EJ503652
2
Power Schematic
48/50A2,A3,A4,A5020-050
50EJ500470
3
48/50A2,A3,A4,A5060 RTPF
50EJ500469
4
48/50A2,A3,A4,A5060 MCHX
50EJ500420
5
Main Control Box Circuit
48/50A2,A3,A4,A5020-060
50EJ500440
6
Auxiliary Control Box Wiring
48/50A2,A3,A4,A5020-060
48EJ503076
7
Controls Expansion
Board Wiring
48/50A2,A3,A4,A5020-060
48EJ503086
8
Gas Heat Control Circuit
(2-Stage Heat)
48A2,A3,A4,A5020-050
48EJ503079
9
48A2,A3,A4,A5060
48EJ503679
10
Gas Heat Control Circuit
(Staged Gas Heat)
48A2,A3,A4,A5020-050
48EJ502488
11
48A2,A3,A4,A5060
48EJ503680
12
Electric Heat Control Circuit
50A2,A3,A4,A5020-050
48EJ503080
13
50A2,A3,A4,A5060
48EJ503655
14
ACCESSORY
UNIT
FIG. NO.
Motormaster® V Low Ambient Controller
48/50A2,A3,A4,A5020-035
15
48/50A2,A3,A4,A5040,050 AND 060 RTPF Units
16
48/50A2,A3,A4,A5060 MCHX Units
17
Space Sensor Temperature Averaging
48/50A2,A3,A4,A5020-060
18
Thermostat
48/50A2,A3,A4,A5020-060
6
Remote Economizer Position Override
Remote Economizer Minimum Position Set Point
Remote 4 to 20 mA Economizer Position
Space IAQ Sensor
Outdoor Enthalpy Changeover Sensor
48/50A2,A3,A4,A5020-060
7
Differential Enthalpy Changeover Sensor
Outdoor Air Quality Sensor
48/50A2,A3,A4,A5020-060
8
Remote Supply Air Set Point
Demand Limit Controller
Fan Status Switch
Demand Limit
Fire Pressurization
Fire Evacuation
Fire Smoke Purge
IAQ Override Switch
WEATHERMAKER
®
48/50A2,A3,A4,A5020-060
Single Package Rooftop
Gas Heating/Electric Cooling and Electric Cooling Units
with
COMFORT
LINK™ Controls
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 ELECTRIC HEAT POWER DIAGRAMS NOTE: All power leads connect to (single) TB7 power terminal block.There are 2 or 3 conductors per terminal. LEGEND AND NOTES FOR FIG. 1-14 UNIT SIZES 50A2,A3,A4,A5 ELECTRICAL CHARACTERISTICS NOMINAL kW FIG. NO. QTY PER UNIT Lo Heat Hi Heat 020-050 208/230-3-60 36 72 1...
4 If the control is connected to a ComfortID™ system, the room terminals are equipped with microprocessor controls that give commands to the base module. If linkage is active, the control module will replace local Comfort Link™ set points and occupancy data with linkage supplied data. If Temperature...
6 INPUT/OUTPUT CHANNEL DESIGNATIONS — ECONOMIZER CONTROL BOARD (ECB1) INPUT/OUTPUT CHANNEL DESIGNATIONS — VAV CONTROL BOARD (ECB2) INPUT/OUTPUT CHANNEL DESIGNATIONS — STAGED GAS HEAT CONTROL BOARD POINT NAME POINT DESCRIPTION I/O POINT NAME PLUG AND PIN REFERENCE SIGNAL PIN(S) PORT STATE INPUTS RMTI...