Table of Contents:

  • Page 2 – LEGEND; PLUG LOCATION REFERENCE
  • Page 4 – Gas Heat Unit Operation —
  • Page 6 – INPUT/OUTPUT CHANNEL DESIGNATIONS — STAGED GAS HEAT CONTROL BOARD
  • Page 7 – INPUT/OUTPUT CHANNEL DESIGNATIONS — CONTROLS EXPANSION BOARD
  • Page 27 – Fig. 21 — Space Temperature Averaging Wiring
  • Page 28 – Fig. 22 — Electric Heater Power Diagrams
Loading the manual

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Catalog No. 04-56480004-01

Printed in U.S.A.

Form 48/50A-4W

Pg 1

7-07

Replaces: 48/50A-2W

Book 1

1

Tab

1a 1b

Wiring Diagrams

UNITS WITH STARTING SERIAL NUMBER 1307UXXXXX AND LATER

INDEX

ACCESSORIES

NOTE: Accessory wiring is shown on the unit wiring diagrams. Refer
to the appropriate drawing for accessory wiring.

ELECTRIC HEAT POWER DIAGRAMS

NOTE: All power leads connect to (single) TB7 power terminal block
– 2 or 3 conductors per terminal.

TYPE

UNIT

NUMBER

FIG. NO.

Component Arrangement

48/50AJ,AK,AW,AY020-035

48EJ502489

1

48/50AJ,AK,AW,AY036-060

48EJ503652

2

Power Schematic

48/50AJ,AK,AW,AY020-027

48EJ503085

3

48/50AJ,AK,AW,AY030-035

48EJ503084

4

48/50AJ,AK,AW,AY036-041

48EJ503653

5

48/50AJ,AK,AW,AY050

48EJ503082

6

48/50AJ,AK,AW,AY051,060

48EJ503654

7

Main Control Box Circuit

48/50AJ,AK,AW,AY020-060

48EJ503075

8

Auxiliary Control Box Wiring

48/50AJ,AK,AW,AY020-060

48EJ503076

9

Controls Expansion

Board Wiring

48/50AJ,AK,AW,AY020-060

48EJ503086

10

Gas Heat Control Circuit

(2-Stage Heat)

48AJ,AK,AW,AY020-050

48EJ503079

11

48AJ,AK,AW,AY051

48EJ503679

12

48AJ,AK,AW,AY060

48EJ503077

13

Gas Heat Control Circuit

(Staged Gas Heat)

48AJ,AW020-050

48EJ502488

14

48AJ,AW051

48EJ503680

15

48AJ,AW060

48EJ503078

16

Electric Heat Control Circuit

50AJ,AK,AW,AY020-050

48EJ503080

17

50AJ,AK,AW,AY051,060

48EJ503655

18

ACCESSORY

UNIT

FIG. NO.

Motormaster® V Low Ambient

Controller

48/50AJ,AK,AW,AY020-035

19

48/50AJ,AK,AW,AY036-060

20

Space Sensor Temperature

Averaging

48/50AJ,AK,AW,AY020-060

21

Thermostat, Remote Economizer Position Override, Remote Economizer Minimum Position Set

Point, Remote 4 to 20 mA Economizer Position, and Space IAQ Sensor

48/50AJ,AK,AW,AY020-060

8

Outdoor Enthalpy Changeover Sensor and Differential Enthalpy Changeover Sensor

48/50AJ,AK,AW,AY020-060

9

Outdoor Air Quality Sensor, Remote Supply Air Set Point, Demand Limit Controller, Outdoor

Inlet CFM Sensor, Fan Status Switch, Demand Limit-Redline, Demand Limit-Loadshed, Fire

Pressurization, Fire Evacuation, Fire Smoke Purge, and IAQ Override Switch

48/50AJ,AK,AW,AY020-060

10

UNIT SIZES

ELEC CHARACTERISTICS

NOMINAL kW

FIG. NO.

QTY PER UNIT

Lo Heat

Hi Heat

020-050

208/230-3-60

36

72

22

2

460-3-60
380-3-60
400-3-50

36
24
27

72
49
54

22

2

575-3-60

36

72

22

2

051,060

208/230-3-60

54

108

22

3

460-3-60
380-3-60
400-3-50

54
37
41

108

74
82

22

3

575-3-60

54

108

22

3

48/50AJ,AK,AW,AY020-060

Single Package Rooftop

Gas Heating/Electric Cooling and Electric Cooling Units

with

COMFORT

LINK™ Controls

50/60 Hz

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Carrier 48AJ

Summary

Page 2 - LEGEND; PLUG LOCATION REFERENCE

2 LEGEND AND NOTES FOR FIG. 1-18 LEGEND BP — Building Pressure C — Contactor, Compressor CAP — Capacitor CB — Circuit Breaker CCB — Control Circuit Breaker CCH — Crankcase Heater CCN — Carrier Communication Network ® CEM — Controls Expansion Module COMP — Compressor Motor CS — Compressor Safety CSB ...

Page 4 - Gas Heat Unit Operation —

4 If the control is connected to a ComfortID™ system, the room terminals are equipped with microprocessor controls that give commands to the base module. If linkage is active, the control module will replace local Comfort Link™ set points and occupancy data with linkage supplied data. If Temperature...

Page 6 - INPUT/OUTPUT CHANNEL DESIGNATIONS — STAGED GAS HEAT CONTROL BOARD

6 INPUT/OUTPUT CHANNEL DESIGNATIONS — ECONOMIZER CONTROL BOARD (ECB1) INPUT/OUTPUT CHANNEL DESIGNATIONS — VAV CONTROL BOARD (ECB2) INPUT/OUTPUT CHANNEL DESIGNATIONS — STAGED GAS HEAT CONTROL BOARD POINT NAME POINT DESCRIPTION I/O POINT NAME PLUG AND PIN REFERENCE SIGNAL PIN(S) PORT STATE INPUTS RMTI...

Other Carrier Models