40QNQ018 with 38QRF018

13 SEER High Wall Duct--- Free Split Heat Pump

with Puron

Refrigerant

Submittal Data

Job Data:_________________________________________________ Location:________________________________________

Buyer:________________________________________ Buyer P.O.#_______________________Carrier # _________________

Unit Number:__________________________________ Model Number: _____________________________________________

Performance Data Certified By: _________________________________________ Date: _______________________________

40QNQ

38QRF

the environmentally sound refrigerant

FEATURES

S

Mounting bracket

S

Microprocessor controls with safeties and diaggnostics

S

Auto restart after power failure

S

User selectable fan speeds plus auto

S

Cleanable filters

S

Motorized louvers

S

Standard remote control with memory

S

Accessory wired user interface

S

Up to 6 units can be controlled with one wired controller

S

Zoning capability

S

Up to 200 ft (61 m) total piping (accessories required)

S

Optional front panel colors

S

Low ambient operation down to --20

_

F (28.9

_

C)

w/accessory

S

Accessory condensate pump

S

Power ventilation accessory

S

Limited Warranty: 1--year parts / 5--year compressor

S

Optional extended parts and labor warranty

Indoor Unit -- 40QNQ / Outdoor Unit -- 38QRF

(Unless otherwise indicated, data applies to both indoor and outdoor models)

SYSTEM SIZE

018

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

REFRIGERANT

R --410A

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PERFORMANCE

Nominal Capacity (Btuh)

18,000

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SEER

13

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

HSPF

7.7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Moisture Removal Rate(Pints/hr)

5.2

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Airflow (Low/Med/High)

460 / 525 / 645

. . . . . . . . . . . . . . . . . . . . . . . .

SOUND PRESSURE (dBA)

Indoor (Low/Med/High)

38 --39 / 42 --43 / 48 --49

. . . . . . . . . . . . . . . .

Outdoor

55

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SOUND POWER (dBA)

Indoor (Low/Med/High)

49 --50 / 53 --54 / 59 --60

. . . . . . . . . . . . . . . .

Outdoor

66

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PERFORMANCE AT ACTUAL CONDITIONS:

Attached

j

Not Attached

j

ELECTRICAL

System Voltage

208/230

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MCA

Indoor

0.48

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Outdoor

12.1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MOCP

Indoor

15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Outdoor

20

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fan Motor (Indoor) (FLA)

0.38

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

CONTROLS

Control Remote (Standard)

Wireless

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Control Voltage

24 VAC

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Control Wiring (0 --50 ft.)

18 AWG

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Control Wiring (75 --200 ft.)

16 AWG

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

REFRIGERANT LINES (Insulate both lines)

Mixed Phase Line (in.) OD

3/8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Vapor Line (in.) OD

5/8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Metering/Control Device

Accurater Piston at outdoor unit

. . . . . . . . . . .

* Refer to NEC and local codes for compliance requirements.

Remote Control

Locking Kit:

Required

j

Not Required

j

Wired Room Control (one unit):

Required

j

Not Required

j

Room Control Wiring Kit for Multiple Units:

Required

j

Not Required

j

Zone Manager:

Required

j

Not Required

j

Zone Manager Wiring Kit:

Required

j

Not Required

j

Condensate Pump:

Required

j

Not Required

j

Low Ambient Kit:

Required

j

Not Required

j

Crankcase Heater:

Required

j

Not Required

j

Wind Baffle:

Required

j

Not Required

j

Isolation Relay:

Required

j

Not Required

j