40QNQ018 with 38QRF018
13 SEER High Wall Duct--- Free Split Heat Pump
with Puron
Refrigerant
Submittal Data
Job Data:_________________________________________________ Location:________________________________________
Buyer:________________________________________ Buyer P.O.#_______________________Carrier # _________________
Unit Number:__________________________________ Model Number: _____________________________________________
Performance Data Certified By: _________________________________________ Date: _______________________________
40QNQ
38QRF
the environmentally sound refrigerant
FEATURES
S
Mounting bracket
S
Microprocessor controls with safeties and diaggnostics
S
Auto restart after power failure
S
User selectable fan speeds plus auto
S
Cleanable filters
S
Motorized louvers
S
Standard remote control with memory
S
Accessory wired user interface
S
Up to 6 units can be controlled with one wired controller
S
Zoning capability
S
Up to 200 ft (61 m) total piping (accessories required)
S
Optional front panel colors
S
Low ambient operation down to --20
_
F (28.9
_
C)
w/accessory
S
Accessory condensate pump
S
Power ventilation accessory
S
Limited Warranty: 1--year parts / 5--year compressor
S
Optional extended parts and labor warranty
Indoor Unit -- 40QNQ / Outdoor Unit -- 38QRF
(Unless otherwise indicated, data applies to both indoor and outdoor models)
SYSTEM SIZE
018
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REFRIGERANT
R --410A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERFORMANCE
Nominal Capacity (Btuh)
18,000
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SEER
13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HSPF
7.7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Moisture Removal Rate(Pints/hr)
5.2
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Airflow (Low/Med/High)
460 / 525 / 645
. . . . . . . . . . . . . . . . . . . . . . . .
SOUND PRESSURE (dBA)
Indoor (Low/Med/High)
38 --39 / 42 --43 / 48 --49
. . . . . . . . . . . . . . . .
Outdoor
55
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SOUND POWER (dBA)
Indoor (Low/Med/High)
49 --50 / 53 --54 / 59 --60
. . . . . . . . . . . . . . . .
Outdoor
66
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERFORMANCE AT ACTUAL CONDITIONS:
Attached
j
Not Attached
j
ELECTRICAL
System Voltage
208/230
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MCA
Indoor
0.48
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Outdoor
12.1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MOCP
Indoor
15
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Outdoor
20
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fan Motor (Indoor) (FLA)
0.38
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CONTROLS
Control Remote (Standard)
Wireless
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Control Voltage
24 VAC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Control Wiring (0 --50 ft.)
18 AWG
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Control Wiring (75 --200 ft.)
16 AWG
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
REFRIGERANT LINES (Insulate both lines)
Mixed Phase Line (in.) OD
3/8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Vapor Line (in.) OD
5/8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Metering/Control Device
Accurater Piston at outdoor unit
. . . . . . . . . . .
* Refer to NEC and local codes for compliance requirements.
Remote Control
Locking Kit:
Required
j
Not Required
j
Wired Room Control (one unit):
Required
j
Not Required
j
Room Control Wiring Kit for Multiple Units:
Required
j
Not Required
j
Zone Manager:
Required
j
Not Required
j
Zone Manager Wiring Kit:
Required
j
Not Required
j
Condensate Pump:
Required
j
Not Required
j
Low Ambient Kit:
Required
j
Not Required
j
Crankcase Heater:
Required
j
Not Required
j
Wind Baffle:
Required
j
Not Required
j
Isolation Relay:
Required
j
Not Required
j