40QNC024 with 38HDF024
13 SEER High Wall Duct--- Free Split --- Cooling Only
with Puron
Refrigerant
Submittal Data
Job Data:_________________________________________________ Location:________________________________________
Buyer:________________________________________ Buyer P.O.#_______________________Carrier # _________________
Unit Number:__________________________________ Model Number: _____________________________________________
Performance Data Certified By: _________________________________________ Date: _______________________________
40QNC
38HDF
the environmentally sound refrigerant
FEATURES
S
13 SEER / 11 EER
S
Remote control standard
S
Optional colored front panels
S
Optional wired controls
S
Auto restart on power failure
S
De--humidification mode
S
User selectable fan speeds (Auto, low, med, high)
S
System diagnostics
S
Cleanable filters
S
Cooling to --20F using low ambient accessories
S
Limited Warranty: 1--year on all parts/5--years on
compressor
Indoor Unit -- 40QNC / Outdoor Unit -- 38HDF
(Unless otherwise indicated, data applies to both indoor and outdoor models)
SYSTEM SIZE
024
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REFRIGERANT
R --410A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPERATING WEIGHT(lb)
Indoor
31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Outdoor
176
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERFORMANCE
Nominal Capacity
Indoor (Btuh)
24,000
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Outdoor (Tons)
2.0
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SEER
13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Moisture Removal Rate(Pints/hr)
7.9
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Airflow (Low/Med/High)
460 / 525 / 645
. . . . . . . . . . . . . . . . . . . . . . . .
ELECTRICAL
Power Wires
10 AWG
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Voltage
208/230
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MCA
Indoor
0.48
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Outdoor
16.8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MOCP
Indoor
15
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Outdoor
25
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fan Motor (Indoor) (FLA)
.38
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motor Watts
64
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CONTROLS
Control Remote (Standard)
Wireless
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Control Voltage
24v
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Control Wiring (0 --50 ft.)
18 AWG
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Control Wiring (75 --200 ft.)
16 AWG
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
REFRIGERANT LINES (Insulate both lines)
Mixed Phase Line (in.) OD
3/8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Vapor Line (in.) OD
5/8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Metering/Control Device
Accurater Piston at outdoor unit
. . . . . . . . . .
Condensate Pump:
Standard
j
Accessory
j
Not Required
j
Crankcase Heater:
Standard
j
Accessory
j
Not Required
j
Isolation Relay:
Standard
j
Accessory
j
Not Required
j
Low Ambient Kit:
Standard
j
Accessory
j
Not Required
j
Remote Control
Lock Mounting Kit:
Standard
j
Accessory
j
Not Required
j
Room Control Wiring Kit
(Multiple Units):
Standard
j
Accessory
j
Not Required
j
Stacking Kit:
Standard
j
Accessory
j
Not Required
j
Wind Baffle:
Standard
j
Accessory
j
Not Required
j
Winter Start Kit:
Standard
j
Accessory
j
Not Required
j
Wired Room
Control (One Unit):
Standard
j
Accessory
j
Not Required
j
Zone Manager:
Standard
j
Accessory
j
Not Required
j
Zone Manager Wiring Kit:
Standard
j
Accessory
j
Not Required
j
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.