38EYG Puron® Cube Heat Pump

024-060 Single Phase

036, 048, 060 Three Phase

Wiring Diagrams

Fig. 1—38EYG024-048; 208-230v; 1 Phase; 60 Hertz

A00004

ORG

ORG

or

or

RVS

BLK

BLK

+t

*ST

+t

BLU

*ST

YEL

DTS

DTS

BLK

*CHS

*CHS

*CH

VPS

VPS

YEL / PNK

SPEED

UP

YEL

5

2

1

23

R

C

S

5

2

1

*DSV

YEL

DFT

BLK

or

PNK

PNK

or

BLK

G

L

E

R

W2

O

Y

C

TERMINAL BLOCK

INDOOR UNIT

RED

WHT

ORN

YEL

BLK

CB

G

W3

L

E

R

W2

O

Y

C

BL

U

/ P

N

K

BRN

YEL / PNK

*HPS

*LPS

23

23

21

11

BLU

LOGIC

LOGIC

S

C

R

YEL

BRN

*

DSV

BLK

L2

L1

BLK

CONT

C

CONT

T2

CTD

T1

C

*HPS

*LPS

Y

Y

DFT

DFT

C

RVS

R

R

W2

O O

OF1

OF2

DR

L2

23

CONT

OFM

CAP

F

C

COMP

H

*SC

*SR

EQUIP

GND

GND

EQUIP

(LADDER FORM)

SCHEMATIC DIAGRAM

21

11

L1

CONT

INDOOR THERMOSTAT (NOTE #5)

SUPPLY

POWER

208/230 1

BLK

BRN

OFM

*SC

*SR

BLU

YEL

CAP

BLK

COMP

YEL

BLK

BLK

BLK

CONNECTION DIAGRAM

*CH

THIS DEFROST CONTROL BOARD CONTAINS A FIVE MINUTE SHORT CYCLE
PROTECTOR. A FIVE MINUTE DELAY WILL OCCUR BETWEEN COMPRESSOR
OFF/ON CYCLES.

JUMPERED TEST PINS (USE METAL OBJECT), FIELD SPEED-UP CYCLE

1) MOMENTARILY SHORT PINS AND RELEASE TO BYPASS COMPRESSOR OFF DELAY.
2) SHORT FOR 5+ SEC. AND RELEASE FOR FORCED DEFROST.
3) PERMANENT SHORT WILL BE IGNORED.

DEFROST WILL TERMINATE IN 30 SEC. IF DFT OPEN.
DEFROST WILL TERMINATE NORMALLY IF DFT IS CLOSED.

* MAY BE FACTORY OR FIELD INSTALLED

COMP

COMPRESSOR

CTD

COMPRESSOR TIME DELAY

CONT

CONTACTOR

CB

CIRCUIT BOARD

DFT

DEFROST THERMOSTAT

DR

DEFROST RELAY AND CIRCUITRY

DTS

DISCHARGE TEMPERATURE SWITCH

*DSV

DISCH. SOLENOID VALVE (WHEN USED)

*HPS

HIGH PRESSURE SWITCH

*LPS

LOW PRESSURE SWITCH

OFM

OUTDOOR FAN MOTOR

RVS

REVERSING VALVE SOLENOID

RVSR

REVERSING VALVE SOLENOID RELAY

*SC

START CAPACITOR

*SR

START RELAY

*ST

START THERMISTOR

VPS

VAPOR PRESSURE SWITCH

325779-101 REV. B

FIELD SELECTABLE OPTIONS FOR TIME PERIOD
BETWEEN DEFROST CYCLES (MINUTES)

NOTES:

1.

COMPRESSOR AND FAN MOTOR FURNISHED WITH INHERENT THERMAL PROTECTION.

2.

TO BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (N.E.C.) AND LOCAL CODES.

3.

N.E.C. CLASS 2, 24 V CIRCUIT, MIN. 40 VA REQUIRED, 60VA ON UNITS INSTALLED WITH LLS.

4.

USE COPPER CONDUCTORS ONLY FROM DISCONNECT TO UNIT.

5.

MUST USE THERMOSTAT AND SUB-BASE AS STATED IN PRE-SALE LITERATURE.

6.

IF INDOOR SECTION HAS A TRANSFORMER WITH A GROUNDED SECONDARY, CONNECT THE GROUNDED
SIDE TO "C" ON THE CIRCUIT BOARD.

7.

IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT WIRE.

8.

CHECK ALL ELECTRICAL CONNECTIONS INSIDE CONTROL BOX FOR TIGHTNESS.

9.

DO NOT ATTEMPT TO OPERATE UNIT UNTIL SERVICE VALVES HAVE BEEN OPENED.

10. USE CONDUCTORS SUITABLE FOR AT LEAST 75 C (167 F).

-LEGEND-

FACTORY POWER WIRING

FIELD POWER WIRING

FACTORY CONTROL WIRING

FIELD CONTROL WIRING

CONDUCTOR ON CIRCUIT BOARD

COMPONENT CONNECTION

1/4-INCH QUICK CONNECT

TERMINALS

FIELD SPLICE

JUNCTION

AUXR

AUXILLARY HEAT RELAY

CAP

CAPACITOR (DUAL RUN)

*CH

CRANKCASE HEATER

*CHS

CRANKCASE HEATER SWITCH

BLK

BLK

RED

RED

BLU / PNK

1

2

3

1

2

3

1

2

3

1

2

3

30 MINUTES

60 MINUTES

(DEFAULT)

90 MINUTES

120 MINUTES

120

30

OR

OR

OR

60

90

DIP SWITCH SETTINGS

1

2

3

QUIET

SHIFT

ON

OFF

(DEFAULT

RVSR

AUXR

DR

OF1

OF2

C Y O W2 R

LOGIC

Y

T1

LOGIC

T2

60

90

120

30

SP

E

ED

UP

R

C

C

DFT

O

PNK

PNK

ORG

ORG

BRN

YEL

CESO130076-01

CTD

RVSR

AUXR

NOTE

Visit www.carrier.com

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book 1

4

Tab

5a 5a

PC 101

Printed in U.S.A.

Catalog No. 38EYG-1W

Pg 1

9-05

Replaces: New