Carrier 38AU- Manual
Carrier 38AU– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – SAFETY CONSIDERATIONS; WARNING; INSTALLATION GUIDELINE
- Page 3 – CAUTION
- Page 10 – A U Z
- Page 11 – Matching 38AU Model To Evaporator Coil; Table 3 – Evaporator Coil Connections; INSTALLATION; Jobsite Survey; Step 1 — Plan for Unit Location; NOTE; Step 2 — Complete Pre-Installation Checks; Check Unit Electrical Characteristics:
- Page 12 – Step 5 — Complete Refrigerant Piping
- Page 13 – Liquid Lift —
- Page 14 – Table 7 –; 8AU Maximum Suction Pipe Size; Vertical Separation (outdoor unit above indoor unit) –
- Page 15 – Table 9 – Refrigerant Specialties Part Numbers.
- Page 16 – drop
- Page 17 – Preliminary Charge —; Step 6 — Install Accessories
- Page 18 – Step 7 — Complete Electrical Connections; to be connected to a 208-v power supply, the control
- Page 19 – Convenience Outlets —
- Page 20 – Convenience Outlet Utilization; NOTICE; ELECTRICAL OPERATION HAZARD; Installing Weatherproof Cover
- Page 22 – Table 10 – Unit Wire/Fuse or HACR Breaker Sizing Data; Legend and Notes for Table 10
- Page 23 – System Check; Turn on the crankcase heater for 24 hours before starting; Preliminary Checks
- Page 24 – Start Unit
- Page 32 – OPERATING SEQUENCE; Base Unit Controls; Cooling, Unit Without Economizer —
- Page 33 – Refrigeration System
- Page 34 – SEAT
- Page 35 – Comfort Alert Diagnostic Module
- Page 36 – Table 11 – LED Status Codes
- Page 37 – Compressor Protection
- Page 38 – Condenser Fans/Motors
- Page 42 – Coil Type Identification
- Page 44 – FASTENER TORQUE VALUES; Table 13 – Torque Values; TROUBLESHOOTING
- Page 46 – APPENDIX A; Air Conditioner & Heat Pump with PURON; warnings; APPENDIX B; Wiring Diagram List; Unit
- Page 47 – APPENDIX C; Low Ambient Option — Factory Installed; Speed Control Sensor Resistance —
- Page 49 – Table 14 – Wind Baffle Dimension
- Page 52 – BOTT
- Page 56 – CHECK VOLTAGE IMBALANCE
1
38AU
Air Cooled Condensing Units
60 Hz
With Puron
R
(R --- 410A) Refrigerant
Sizes 16 --- 25
Installation, Start --- Up and
Service Instructions
CONTENTS
SAFETY CONSIDERATIONS
2
. . . . . . . . . . . . . . . . . . . .
INSTALLATION GUIDELINES
2
. . . . . . . . . . . . . . . . . .
Replacement/Retrofit — R--22 to Puron
2
. . . . . . . . . . .
INSTALLATION
11 - 22
. . . . . . . . . . . . . . . . . . . . . . . . .
Jobsite Survey
11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Step 1 -- Plan for Unit Location
11
. . . . . . . . . . . . . . . . .
Step 2 -- Complete Pre--Installation Checks
11
. . . . . . . .
Step 3 – Prepare Unit Mounting Support
12
. . . . . . . . . .
Step 4 – Rig and Mount the Unit
12
. . . . . . . . . . . . . . . .
Step 5 – Complete Refrigerant Piping Connections
12
. . .
Step 6 – Install Accessories
17
. . . . . . . . . . . . . . . . . . . .
Step 7 – Complete Electrical Connections
18
. . . . . . . . .
PRE-START-UP
23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Check
23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Turn On Crankcase Heater
23
. . . . . . . . . . . . . . . . . . . . .
Preliminary Charge
23
. . . . . . . . . . . . . . . . . . . . . . . . . . .
START--UP
23 - 31
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preliminary Checks
23
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Start Unit
24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPERATING SEQUENCE
32
. . . . . . . . . . . . . . . . . . . . . .
Indoor (Supply) Fan
32
. . . . . . . . . . . . . . . . . . . . . . . . . .
Cooling, Unit Without Economizer
32
. . . . . . . . . . . . . .
Cooling, Unit With Economizer
32
. . . . . . . . . . . . . . . . .
Heating
32
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ROUTINE SYSTEM MAINTENANCE
33
. . . . . . . . . . . .
Quarterly Inspection (and 30 days after initial start)
33
. . .
Seasonal Maintenance
33
. . . . . . . . . . . . . . . . . . . . . . . .
SERVICE
33 - 44
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Refrigeration System
33
. . . . . . . . . . . . . . . . . . . . . . . . .
Compressor Oil
33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Servicing Systems on Roofs with
Synthetic Materials
33
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Liquid Line Filter Drier
34
. . . . . . . . . . . . . . . . . . . . . . .
Field Refrigerant Access Ports
34
. . . . . . . . . . . . . . . . . .
Factory High--Flow Access Ports
34
. . . . . . . . . . . . . . . .
Comfort Alert Diagnostic Module
35
. . . . . . . . . . . . . . .
Compressor Protection
37
. . . . . . . . . . . . . . . . . . . . . . . .
Crankcase Heater
37
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low--Pressure Switch
37
. . . . . . . . . . . . . . . . . . . . . . . . .
High--Pressure Switch
37
. . . . . . . . . . . . . . . . . . . . . . . . .
Outdoor Fans
37
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lubrication
37
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Coil Type Identification
42
. . . . . . . . . . . . . . . . . . . . . . .
NOVATION
t
Coil Cleaning and Maintenance
42
. . . . .
Repairing NOVATION Condenser Tube Leaks
42
. . . . .
Replacing NOVATION Condenser Coil
43
. . . . . . . . . . .
Routine Cleaning of Round-Tube Plate Fin
(RTPF) Coils
43
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fastener Torque Values
44
. . . . . . . . . . . . . . . . . . . . . . . .
TROUBLESHOOTING
44 -- 45
. . . . . . . . . . . . . . . . . . . . .
APPENDIX A
Air Conditioner & Heat Pump with Puron
R
—
Quick Reference Guide
46
. . . . . . . . . . . . . . . . . . . . . . . . .
APPENDIX B
Wiring Diagram List
46
. . . . . . . . . . . . . . . . . . . . . . . . . . .
APPENDIX C
Low Ambient Option — Factory Installed
47
. . . . . . . . . .
START--UP CHECKLIST
55 -- 56
. . . . . . . . . . . . . . . . . . .
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Carrier 38AU
Summary
2 SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for inf...
3 Same tube sizes are capable of handling higher flowrates (expressed as tons of cooling capacity) with Puron refrigerant compared to R--22 at constant pressure drops. For example, a 1 / 2 --inch OD liquid line is rated at 33% higher tons with Puron R than with R--22 (at 5 _ F pressure drop). A 1 1 ...
10 Model Type 38AU= Carrier Condensing Unit Puron ® R --- 410A Refrigerant Type of Coil D = Dual Circuit, A/C Scroll Compressor Z = Single Circuit, A/C Scroll Compressor Refrigerant Options A = None B = Low Ambient Nominal Tonnage 16 = 15 Tons 25 = 20 Tons Not Used A = Not Used Not Used 0 = Not Used...