Carrier 38AK012- User Manual

Carrier 38AK012

Carrier 38AK012– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 4 – Table 2 — Weight Distribution; Step 2 — Rig and Mount the Unit; Table 3A — Refrigerant Piping Sizes — 60 Hz; Table 3B — Refrigerant Piping Sizes — 50 Hz
  • Page 5 – Fig. 3 — Rigging Label
  • Page 6 – Step 4 — Make Electrical Connections; Fig. 5 — Power Wiring Connections
  • Page 7 – Table 5 — Electrical Data; not
  • Page 8 – Fig. 7 — Field Control Wiring Raceway
  • Page 9 – Fig. 8A — Cooling Charging Chart — 38AK007
  • Page 11 – Fig. 11 — Propping Up Top Panel; UNIT; Fig. 10 — Cleaning Condenser Coil
  • Page 12 – Fig. 14 — Compressor Capacity Control Unloader
  • Page 13 – TROUBLESHOOTING GUIDE; SYMPTOM
  • Page 14 – LEGEND AND NOTES FOR FIG. 15 AND 16; Fig. 15 — Typical 38AK Component Arrangement
  • Page 15 – A. Preliminary Information; INDOOR: AIR HANDLER MANUFACTURER
  • Page 16 – CHECK VOLTAGE IMBALANCE
Loading the manual

Installation, Start-Up and

Service Instructions

CONTENTS

Page

SAFETY CONSIDERATIONS

. . . . . . . . . . . . . . . . . . . 1

INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8

Step 1 — Complete Pre-Installation Checks

. . . 1

• UNCRATE UNIT
• INSPECT SHIPMENT
• CONSIDER SYSTEM REQUIREMENTS

Step 2 — Rig and Mount the Unit

. . . . . . . . . . . . . 4

• RIGGING
• COMPRESSOR MOUNTING

Step 3 — Complete Refrigerant Piping

Connections

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

• SIZE REFRIGERANT LINES
• FILTER DRIER AND MOISTURE INDICATOR

Step 4 — Make Electrical Connections

. . . . . . . . 6

• FIELD POWER SUPPLY
• FIELD CONTROL WIRING

START-UP

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9,10

Preliminary Checks

. . . . . . . . . . . . . . . . . . . . . . . . . . 9

Evacuate and Dehydrate

. . . . . . . . . . . . . . . . . . . . . . 9

Refrigerant Charge

. . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Compressor Overload

. . . . . . . . . . . . . . . . . . . . . . . . 9

Cycle-LOC™ Device

. . . . . . . . . . . . . . . . . . . . . . . . . . 9

Low-Pressure/Loss-of-Charge Switch (LPS)

. . . 9

High-Pressure Switch (HPS)

. . . . . . . . . . . . . . . . . 10

Time Guard

T

II Device

. . . . . . . . . . . . . . . . . . . . . . . 10

Refrigerant Service Ports

. . . . . . . . . . . . . . . . . . . 10

Cooling

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Sequence of Operation

. . . . . . . . . . . . . . . . . . . . . . 10

Oil Charge

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

SERVICE

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11,12

Cleaning

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Lubrication

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Condenser-Fan Adjustment

. . . . . . . . . . . . . . . . . . 11

Capacity Control — Unit 38AKS012 Only

. . . . . 12

Compressor Removal

. . . . . . . . . . . . . . . . . . . . . . . 12

Crankcase Heater

. . . . . . . . . . . . . . . . . . . . . . . . . . . 12

TROUBLESHOOTING GUIDE

. . . . . . . . . . . . . . . 13,14

START-UP CHECKLIST

. . . . . . . . . . . . . . . CL-1, CL-2

SAFETY CONSIDERATIONS

Installing and servicing air-conditioning equipment can be

hazardous due to system pressure and electrical compo-
nents. Only trained and qualified service personnel should
install or service air-conditioning equipment.

When working on air-conditioning equipment, observe pre-

cautions in literature and on tags and labels attached to unit.

Follow all safety codes. Wear safety glasses and work gloves.

Use quenching cloth for brazing operations. Have fire ex-
tinguisher available. Read these instructions thoroughly. Con-
sult local building codes and National Electrical Code (NEC)
(U.S.A. Standard) for special installation requirements.

Before installing or servicing system, always turn off
main power to system. There may be more than one
disconnect switch. Electrical shock can cause personal
injury.

INSTALLATION

The 38AK007, 008, and 012 units use hermetic compres-

sors. The 38AKS008, 009, and 012 units use semi-hermetic
compressors. See Table 1A or 1B for physical data.

Step 1 — Complete Pre-Installation Checks

UNCRATE UNIT (See Fig. 1) — Remove unit packaging
except for the top skid assembly and wood bumpers, which
should be left in place until after unit is rigged into place.
INSPECT SHIPMENT — File claim with shipping com-
pany if shipment is damaged or incomplete.

Fig. 1 — Model 38AK (Size 007 Shown)

38AK007,008,012

38AKS008,009,012

Air-Cooled Condensing Units

50/60 Hz

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book 1

4

Tab

3a 2a

PC 111

Catalog No. 533-876

Printed in U.S.A.

Form 38A-7SI

Pg 1

5-99

Replaces: 38A-6SI

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Carrier 38AK012

Summary

Page 4 - Table 2 — Weight Distribution; Step 2 — Rig and Mount the Unit; Table 3A — Refrigerant Piping Sizes — 60 Hz; Table 3B — Refrigerant Piping Sizes — 50 Hz

CONSIDER SYSTEM REQUIREMENTS• Consult local building codes and NEC for special instal- lation requirements. • Allow sufficient space for airflow clearance, wiring, refrigerant piping, and unit servicing. See Fig. 2. • Locate unit so that condenser airflow is unrestricted on all sides and above. Refe...

Page 5 - Fig. 3 — Rigging Label

UNIT 38 DIM. A DIM. B DIM. C DIM. D DIM. E DIM. F AK007 1 8 -6 1 ⁄ 2 9 1 8 -2 3 ⁄ 4 9 — 1 8 -2 1 ⁄ 4 9 1 8 -4 5 ⁄ 16 9 2 8 -9 5 ⁄ 16 9 [470.0] [375.0] — [362] [415] [846.5] AK008 1 8 -8 9 1 8 -6 1 ⁄ 2 9 — 1 8 -3 9 2 8 - 5 ⁄ 16 9 3 8 -5 7 ⁄ 16 9 [508.0] [470.0] — [381] [613] [1052.5] AK012 1 8 -9 9 1...

Page 6 - Step 4 — Make Electrical Connections; Fig. 5 — Power Wiring Connections

FILTER DRIER AND MOISTURE INDICATOR — The fil-ter drier is factory installed. Moisture indicator is field-supplied and should be installed just after liquid line shutoffvalve. Do not use a receiver; there is none provided withunit and one should not be used.NOTE: Unit is shipped with R-22 holding ch...

Other Carrier Models