Carrier 24ACC624A0030010 - Installation Manual

Carrier 24ACC624A0030010

This Installation Manual covers Carrier’s Single-Stage Performance™ Series air conditioners with Puron® refrigerant, focusing on safety protocols, refrigerant handling, and system setup requirements. Key topics include electrical installation guidelines–such as proper wiring, grounding, and clearance specifications–to prevent hazards like shock or explosion, alongside detailed procedures for refrigerant charging (superheat/subcooling methods) and evacuation techniques. The document also addresses mounting, piping diagrams, tiedown specifications, and accessory compatibility for various HVAC applications, emphasizing adherence to safety standards and optimal performance conditions.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
Page: / 10

Table of Contents:

  • Page 1 – Installation Safety and Piping Guidelines
  • Page 2 – Unit Installation and Mounting Specifications
  • Page 3 – Refrigeration System Evacuation Procedures
  • Page 4 – Indoor Piston Installation and Refrigerant Charging Methods
  • Page 5 – Refrigerant Charging Reference Tables
  • Page 6 – Suction-Line Temperature Calculation
  • Page 7 – Electrical Installation and System Startup
  • Page 8 – Refrigerant Charge Adjustment and Maintenance
  • Page 9 – Accessory Wiring and Application Requirements
  • Page 10 – Refrigerant Handling and Service Specifications
Loading the manual
Page 1

Installation Instructions

24ACB3, 24ACC6 24APB6

Single --- Stage Performance

t

Series Air Conditioners

with Puron

r

Refrigerant

1 --- 1/2 To 5 Nominal Tons (Sizes 18 to 60)

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other

conditions which may cause death, personal injury, or property
damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The qualified

installer or agency must use factory--authorized kits or accessories
when modifying this product. Refer to the individual instructions

packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,

and work gloves. Use quenching cloth for brazing operations.
Have fire extinguisher available. Read these instructions

thoroughly and follow all warnings or cautions included in

literature and attached to the unit. Consult local building codes
and current editions of the National Electrical Code ( NEC ) NFPA

70. In Canada, refer to current editions of the Canadian electrical
code CSA 22.1.

Recognize safety information. This is the safety--alert symbol

When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury. Understand

these signal words; DANGER, WARNING, and CAUTION. These

words are used with the safety--alert symbol. DANGER identifies
the most serious hazards which

will

result in severe personal injury

or death. WARNING signifies hazards which

could

result in

personal injury or death. CAUTION is used to identify unsafe

practices which

would

result in minor personal injury or product

and property damage. NOTE is used to highlight suggestions
which

will

result in enhanced installation, reliability, or operation.

!

WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal

injury or death.
Before installing, modifying, or servicing system, main

electrical disconnect switch must be in the OFF position.

There may be more than 1 disconnect switch. Lock out and

tag switch with a suitable warning label.

EXPLOSION HAZARD

Failure to follow this warning could

result in death, serious personal injury,

and/or property damage.
Never use air or gases containing

oxygen for leak testing or operating

refrigerant compressors. Pressurized

mixtures of air or gases containing

oxygen can lead to an explosion.

!

WARNING

GENERAL

NOTE

: In some cases noise in the living area has been traced to

gas pulsations from improper installation of equipment.

1. Locate unit away from windows, patios, decks, etc. where

unit operation sound may disturb customer.

2. Ensure that vapor and liquid tube diameters are appropriate

for unit capacity.

3. Run refrigerant tubes as directly as possible by avoiding un-

necessary turns and bends.

4. Leave some slack between structure and unit to absorb vi-

bration.

5. When passing refrigerant tubes through the wall, seal open-

ing with RTV or other pliable silicon--based caulk. (See Fig.
1.)

6. Avoid direct tubing contact with water pipes, duct work,

floor joists, wall studs, floors, and walls.

7. Do not suspend refrigerant tubing from joists and studs with

a rigid wire or strap which comes in direct contact with
tubing. (See Fig. 1.)

8. Ensure that tubing insulation is pliable and completely sur-

rounds vapor tube.

9. When necessary, use hanger straps which are 1 in. (25.4

mm) wide and conform to shape of tubing insulation. (See

Fig. 1.)

10. Isolate hanger straps from insulation by using metal sleeves

bent to conform to shape of insulation.

INSULATION

VAPOR TUBE

LIQUID TUBE

OUTDOOR WALL INDOOR WALL

LIQUID TUBE

VAPOR TUBE

INSULATION

CAULK

Avoid contact between tubing and structure

NOTE:

THROUGH THE WALL

HANGER STRAP

(AROUND VAPOR

TUBE ONLY)

JOIST

1” (25.4 mm) MIN.

SUSPENSION

A94026

Fig. 1 -- Piping Installation

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Carrier
Model
24ACC624A0030010
Document type
Installation Manual
Language(s)
English
Pages
10
File size
392.4 KB
Format
PDF

Summary

Page 1 - Installation Safety and Piping Guidelines

Safety guidelines and general installation instructions for Single-Stage Performance™ Series Air Conditioners, including precautions against electrical shock and explosion hazards, and proper piping installation through walls.

Page 2 - Unit Installation and Mounting Specifications

Instructions and safety warnings for air conditioning unit installation, covering refrigerant charging, equipment inspection, mounting requirements, clearance specifications, and tiedown knockout locations.

Page 3 - Refrigeration System Evacuation Procedures

Guidelines for refrigeration system installation and evacuation, focusing on outdoor unit connections, filter drier installation, deep vacuum procedures, refrigerant tube sizing, and vacuum level monitoring.

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.