  • Page 2 – Operating Instructions and Parts Manual; Inverter Technology Arc Welder; Controls – Back Panel; CAUTION; DANGER; Always attach the ground lead first.; DANGER; Electrode Polarity Chart; Auto Strike
  • Page 3 – ADDITIONAL SAFETY STANDARDS; from American; Safety and Health Standards; NFPA Standard 70, from National Fire; Do not perform electric arc welding; Current
  • Page 4 – Cutting And Welding Processes; Installation; LOCATION; WELDING HELMET ASSEMBLY; Operation
  • Page 5 – Maintenance; Check condition of weld cables and; Welding Guidelines; Striking an Arc
  • Page 6 – reduce tiring of the hand and arm.; Arc Welding Basics; Electrode Type and Size; Commonly Used Electrodes; Travel Angle; AWS Electrode Classification
  • Page 7 – WELD PASSES
  • Page 9 – Troubleshooting Chart; dedicated; For Information About This Product
  • Page 10 – Limited Warranty
  • Page 11 – Welding Terms
  • Page 12 – Replacement Parts List; For Information About
  • Page 13 – Instructions D’Utilisation & Manuel De Pièces; AVERTISSEMENT; Rallonges – Longueur à la sortie nominale
  • Page 14 – Contrôles – Panneau arrière; ATTENTION; Soudeur à l'arc à technologie de convertisseur; Tableau de polarité
  • Page 15 – a. Enlever l’enduit du métal; Ne jamais enrouler les câbles de; Courant
  • Page 17 – Fonctionnement; Mettre le soudeur hors circuit et le; Entretien; Guide d'ampérage de sortie
  • Page 18 – 0= Acier à haute teneur; Classement D’Électrodes AWS
  • Page 19 – Idéal pour les travaux décoratifs.; COURANT; La vitesse de déplacement indique la; Figure 8 - Angle De Travail
  • Page 20 – RETRAIT DES SCORIES; POSITIONS DE SOUDAGE; Soudeur À L’Arc Au Métal Enrobé
  • Page 21 – varient selon la position.; PASSES DE SOUDAGE; Garantie Limitée
  • Page 22 – Guide De Dépannage - Soudeur; Pour Des Informations Concernant Ce Produit,
  • Page 24 – Lexique De Termes De Soudage
  • Page 25 – Grapa de trabajo con conductor de; ADVERTENCIA; Manual de instrucciones y lista de repuestos; Descripción; PRECAUCION; Controles – Panel delantero; Especificaciones de energía
  • Page 26 – Entrada de cordón de corriente; Entrada de cordón de corriente; PELIGRO; PELIGRO; Tabla de Polaridad del Electrodo; Acción automática
  • Page 27 – Corriente
  • Page 28 – MEDIDAS DE SEGURIDAD ADICIONALES; Instalación; UBICACIÓN
  • Page 29 – Funcionamiento; Mantenimiento; Guía de salida de amperaje
  • Page 30 – situaciones diferentes.; PARA ENCENDER EL ARCO; TAMAÑO Y TIPO DEL ELECTRODO
  • Page 31 – = Electrodo se puede; CLASIFICACION AWS DEL ELECTRODO
  • Page 32 – POSICIONES PARA SOLDAR; Básicamente hay 4 posiciones para; PASOS
  • Page 33 – Garantía Limitada
  • Page 34 – DIAGNOSTICO DE AVERIAS; Para mayor información sobre este producto llame al
  • Page 35 – Para mayor información; Lista de Repuestos
  • Page 36 – Glosario de Terminología usada por soldadores
Loading the manual

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

IN971600AV 4/03

Operating Instructions & Parts Manual

Model WS2100

Arcitech
Inverter Technology
Arc Welder

B U I L T T O L A S T

Description

The future of welding has arrived! The
Campbell Hausfeld Arcitech

arc

welder uses inverter technology to
eliminate the mass and weight of
traditional transformer welders, giving
you amazing power in a tiny portable
package. This constant-current power
source delivers smooth DC power for
high quality welds with the SMAW
(shielded metal arc welding) process
using stick electrodes. It can also be
converted to a TIG (tungsten inert gas)
welder with the optional TIG torch
(WT6100) and a bottle of inert gas
with a regulator.

The Campbell Hausfeld Arcitech

welder runs on 115 Volt – 20 Amp
single phase input power. It is
equipped with infinite amperage
control to accurately select the proper
current needed for various welding
conditions. Internal components are
thermostatically protected.

Unpacking

When unpacking, inspect carefully for
any damage that may have occurred
during transit. Make sure any loose
fittings and screws, etc. are tightened
before putting unit into service.

Circuit Requirements

This equipment
requires a

dedicated 115 volt circuit. Refer to the
following chart for the correct circuit
breaker or fuse rating. Do not run
other appliances, lights, or tools on
this circuit while operating this
equipment.. See chart for proper
extension cord use. Blown fuses and
tripped circuit breakers can result from
failure to comply with this
recommendation.

!

CAUTION

Specifications

The electrode
holder is "live"

(has current potential) when machine is
turned on.

Components

(See Figure 1)

1. Work Clamp with 10’ lead and dinse

plug connector

!

WARNING

2. Electrode Holder with 15’ lead and

dinse plug connector

3. Power Cord – 7.5’ – 14AWGX3C-SJT

Controls – Front Panel

(See Figure 2)

1. Infinite amperage control knob –

controls 5-110 Amps DC output

2. Positive Dinse plug connector:

a) Connect electrode holder for
“reverse” (DCEP) polarity.
b) Connect work clamp for “straight”
(DCEN) polarity.

3. Negative Dinse plug connector:

a) Connect work clamp for “reverse”
(DCEP) polarity.
b) Connect electrode holder for
“straight” (DCEN) polarity.

4. Yellow LED – Normally off. When lit it

means that welding current is shut off
due to:
a) Thermal overload – duty cycle is
exceeded – allow to cool for 15
minutes.
b) Input voltage outside of safe

For parts, manuals, product & service information

visit

www.chpower.com

or call 800-746-5641

© 2003 Campbell Hausfeld

Extension Cords – Length at Rated Output

Weld Output Amps 55

65

90

Cord Gauge

Cord Length – Feet

14 Gauge Cord

65

50

25

12 Gauge Cord

100

75

50

10 Gauge Cord

150

125

100

Figure 1 - Welder Components and Controls

Input Current at Rated Output

Input Amps AC

16

19

24

Output Amps DC

55

65

90

Weld Volts DC

22

23

24

Duty Cycle

100% 60%

35%

Power Specifications

Single Phase

50/60 Hz

115 Volts

1

3

2

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Operating Instructions and Parts Manual; Inverter Technology Arc Welder; Controls – Back Panel; CAUTION; DANGER; Always attach the ground lead first.; DANGER; Electrode Polarity Chart; Auto Strike

2 Operating Instructions and Parts Manual Inverter Technology Arc Welder parameters. (115 volts +/- 10%) 5. Green LED – On = ready to weld. Controls – Back Panel (See Figure 3) 1.On/Off Switch: O = Off I = On 2.Power Cord input General Safety Danger means ahazard that will cause death or serious inj...

Page 3 - ADDITIONAL SAFETY STANDARDS; from American; Safety and Health Standards; NFPA Standard 70, from National Fire; Do not perform electric arc welding; Current

operations on metals that aregalvanized or cadmium plated, orcontain zinc, mercury, or berylliumwithout completing the followingprecautions: a. Remove the coating from the base metal. b. Make sure that the welding area is well ventilated. c. Use an air-supplied respirator. Extremely toxic fumes are ...

Page 4 - Cutting And Welding Processes; Installation; LOCATION; WELDING HELMET ASSEMBLY; Operation

WT2240 Electrode Container, topreserve the flux coating. ● The welder control panel containsinformation regarding proper inputvoltage and amperage. Follow thespecifications on the welder frontpanel. ● The receptacle used for the weldermust be properly grounded and the welder must be the only load on...

Other Campbell Hausfeld Models