Campbell Hausfeld WL6000 - Manual

Campbell Hausfeld WL6000

Campbell Hausfeld WL6000 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – Location; TANK MOUNTING; Oilless Stationary Compressors; SPRAYING PRECAUTIONS; NOTICE; Installation
  • Page 4 – Operation
  • Page 6 – Troubleshooting Chart
  • Page 8 – Operating Instructions; Limited Warranty
  • Page 9 – AVERTISSEMENT; Lire attentivement tous; Instructions D’Utilisation; Avertissement D’Air Respirable; DANGER; Date d’Achat; Ces; AVIS; Directives De Sécurité
  • Page 10 – Compresseur Sans Huile; PRÉCAUTIONS DE PULVÉRISATION
  • Page 11 – ATTENTION
  • Page 12 – Fonctionnement
  • Page 14 – Guide De Dépannage
  • Page 16 – Instructions d’Utilisation; Garantie Limitée
  • Page 17 – ADVERTENCIA; Estos aparatos; AVISO; Instrucciones para la Operacion; Advertencia sobre el; PELIGRO; Descripción
  • Page 18 – Compresores Sin Aceite; PRECAUCIONES PARA ROCIAR; UBICACION; Instalación
  • Page 20 – PRECAUCION; Funcionamiento
  • Page 21 – Mantenimiento
  • Page 22 – Instrucciones para la operacion; Guía de diagnóstico de averías
  • Page 23 – Guía de diagnóstico de averías (Continuación)
  • Page 24 – Garantía Limitada
Loading the manual

Since the air compressor and other
components (material pump, spray
guns, filters, lubricators, hoses, etc.)
used, make up a high pressure
pumping system, the following safety
precautions must be observed at all
times:

1. Read all manuals

included with this
product carefully. Be
thoroughly familiar
with the controls and
the proper use of the equipment.

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

© 1997 Campbell Hausfeld

Operating Instructions

WL6000 Series

IN203402AV 11/97

Breathable Air Warning

This compressor/pump is NOT
equipped and should NOT be used “as
is” to supply breathing quality air. For
any application of air for human
consumption, you must fit the air
compressor/pump with suitable in-line
safety and alarm equipment. This
additional equipment is necessary to
properly filter and purify the air to
meet minimal specifications for Grade
D breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 - 1966,
OSHA 29 CFR 1910. 134, and/or
Canadian Standards Associations
(CSA).

DISCLAIMER OF WARRANTIES
IN THE EVENT THE COMPRESSOR IS
USED FOR THE PURPOSE OF
BREATHING AIR APPLICATION AND
PROPER IN-LINE SAFETY AND ALARM
EQUIPMENT IS NOT SIMULTANEOUSLY
USED, EXISTING WARRANTIES ARE
VOID, AND CAMPBELL HAUSFELD
DISCLAIMS ANY LIABILITY
WHATSOEVER FOR ANY LOSS,
PERSONAL INJURY OR DAMAGE.

MANUAL

STOP!

Record the Model No., Serial No. and
date of purchase located on the base
below the pump in the space below.

Model No. ____________________

Serial No. ____________________

Date of purchase _________________

Retain these numbers for future
reference
.

Q

UA

LIT

Y

A

SSURANCE

P

ROG

RA

M

Need

Assistance?

Call Us First!

1-800-543-8622

Oilless
Stationary
Compressors

questions, damaged or missing parts,
please call 1-800-543-6400 for customer
assistance or call the nearest Campbell
Hausfeld Authorized Service Center.

A listing of service center locations is
enclosed. Have the serial number,
model number and parts list (with
missing parts circled before calling).

Do not operate
unit if damaged

during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.

Oilless compressors are designed for
do-it-yourselfers with a variety of home
and automotive jobs. These compres-
sors will power spray guns, impact
wrenches and other tools.

These units

operate without oil.

This manual contains information that
is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.

Danger indicates
an imminently

hazardous situation which, if not
avoided, WILL result in death or serious
injury.

Warning indicates
a potentially

hazardous situation which, if not
avoided, COULD result in death or
serious injury.

Caution indicates a
potentially

hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.

Notice indicates

important

information, that if not followed, MAY
cause damage to equipment.

After unpacking the unit, inspect
carefully for any damage that may have
occurred during transit. Make sure to
tighten fittings, bolts, etc., before
putting unit into service. In case of

!

NOTICE

B U I L T T O L A S T

TM

Safety Guidelines

Description

Unpacking

DO NOT RETURN THE
PRODUCT TO THE
RETAILER!

General Safety
Information

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Location; TANK MOUNTING; Oilless Stationary Compressors; SPRAYING PRECAUTIONS; NOTICE; Installation

16.Do not direct paint or other sprayed material at the compressor. Locatecompressor as far away from thespraying area as possible tominimize overspray accumulationon the compressor. 17.When spraying or cleaning with solvents or toxic chemicals, followthe instructions provided by thechemical manufac...

Page 4 - Operation

4 Operating Instructions Oilless Stationary Compressors LUBRICATION This is an oilless product and DOES NOT require lubrication to operate. BREAK-IN PROCEDURE Do not attach air chuck or other tool to open end of hose until start-up hasbeen completed and unit checks OK. IMPORTANT: Do not operate comp...

Page 6 - Troubleshooting Chart

6 Operating Instructions Oilless Stationary Compressors Troubleshooting Chart Symptom Possible Cause(s) Corrective Action 1. No electrical power 2. Blown fuse 3. Breaker open 4. Thermal overload open 5. Pressure switch bad 6. Check valve defective 1. Poor contacts, line voltage incorrect 2. Shorted ...

Other Campbell Hausfeld Models

All Campbell Hausfeld Other