Campbell Hausfeld IN615601AV - Manual

Campbell Hausfeld IN615601AV

Campbell Hausfeld IN615601AV – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – Oil-Lubricated Compre s s o r s; SPRAYING PRECAUTIONS; A s s e m b l y; HANDLE ASSEMBLY
  • Page 3 – I n s t a l l a t i o n; L O C A T I O N; W I R I N G; Extension cords for; Side view of unit; Assembly
  • Page 4 – Operation
  • Page 5 – PRESSURE GAUGES; M a i n t e n a n c e; OIL CHANGE; O p e r a t i o n
  • Page 6 – Troubleshooting Chart
  • Page 7 – . Check tank for leaks with soap and water solution. If
  • Page 8 – Limited Wa rr a n t y; WHAT IS NOT COVERED UNDER THIS WARRANTY:
  • Page 9 – . Lire attentivement tous; © 2008 Campbell Hausfeld/Scott Fetzer; D e s c r i p t i o n; D é b a l l a g e; Instructions D’Utilisation; Av e rtissement D’Air Respirable; Date d’Achat; C o m p resseur Graissé par l'Huile; MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie!
  • Page 10 – PRÉCAUTIONS DE PULVÉRISATION; A s s e m b l a g e; MONTAGE DE ROUE
  • Page 11 – Ne pas utiliser d'huile; E N D R O I T; INSTALLATION ÉLECTRIQUE; C Â B L A G E; Vue latérale de l’appareil
  • Page 12 – F o n c t i o n n e m e n t; Cordons Prolongateurs Pour
  • Page 13 – MANOMÈTRES; E n t re t i e n; CHANGER L’HUILE
  • Page 14 – Guide De Dépannage
  • Page 16 – Garantie Limitée; Les
  • Page 17 – Para Desempacar; Instrucciones para la Operacion; C o m p resor lubricado con aceite; Adjúntela a este manual o archívela en lugar seguro.
  • Page 18 – PRECAUCIONES PARA ROCIAR; E n s a m b l a j e; ENSAMBLE DEL MANGO; MONTAJE DE LA RUEDA
  • Page 19 – I n s t a l a c i ó n; Vista lateral de la unidad; Ensamblaje
  • Page 20 – F u n c i o n a m i e n t o; Instalación; Cordones de extensión para los
  • Page 21 – MANÓMETROS; M a n t e n i m i e n t o; CAMBIOS DE ACEITE
  • Page 22 – Guía de diagnóstico de averías
  • Page 23 – Guía de diagnóstico de averías (Continuación)
  • Page 24 – Garantía Limitada; Los compresores marca Maxus tienen una garantía de 5 (cinco) años.
Loading the manual

Do not run
unattended. Leaving

compressor in AUTO position may allow it
to turn on inadvertently. To prevent this
and possible damage from power surge,
turn to OFF position after each use.

Since the air compressor and other
components (filters, lubricators, hoses,
etc.) used, make up a high pressure
pumping system, the following safety
precautions must be observed at all times:

1 . Read all manuals

included with this
product carefully. Be
thoroughly familiar
with the controls and
the proper use of the equipment.

General Safety
I n f o rm a t i o n

CALIFORNIA PROPOSITION 65

You can create dust
when you cut, sand,

drill or grind materials such as wood,
paint, metal, concrete, cement, or other
masonry. This dust often contains
chemicals known to cause cancer, birth
defects, or other reproductive harm.
Wear protective gear.

This product or its
power cord may

contain chemicals, including lead, known
to the State of California to cause cancer
and birth defects or other reproductive
harm. Wash hands after handling.

GENERAL SAFETY INFORMATION

Do not operate
unit if damaged

during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

© 2008 Campbell Hausfeld/Scott Fetzer

D e s c r i p t i o n

This residential oil-lubricated compressor
is designed for do-it-yourselfers with a
variety of home and automotive jobs.
These compressors power spray guns,
impact wrenches and other tools.
Compressed air from this unit will
contain moisture. Install a water filter or
air dryer if application requires dry air.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT E Q U I P M E N T P R O B L E M S .
To help recognize this information,
observe the following symbols.

Danger indicates
an imminently

hazardous situation which, if not avoided,
WILL result in death or serious injury.

Warning indicates
a potentially

hazardous situation which, if not
avoided, COULD result in death or
serious injury.

Caution indicates a

p o t e n t i a l l y

hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.

Notice indicates

i m p o r t a n t

information, that if not followed, M A Y
cause damage to equipment.

U n p a c k i n g

After unpacking the unit, inspect
carefully for any damage that may have
occurred during transit. Make sure to
tighten fittings, bolts, etc., before
putting unit into service. In case of
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
assistance or call the nearest Campbell
Hausfeld Authorized Service Center.
Have the serial number, model number,
and parts list (with missing parts circled)
before calling.

Operating Instructions

IN615601AV 12/08

B reathable Air Wa rn i n g

This compressor/pump is not equipped
and should not be used “as is” to
supply breathing quality air. For any
application of air for human
consumption, the air
compressor/pump will need to be
fitted with suitable in-line safety and
alarm equipment. This additional
equipment is necessary to properly
filter and purify the air to meet
minimal specifications for Grade D
breathing as described in Compressed
Gas Association Commodity
Specification G 7.1 - 1966, OSHA 29 CFR
1910. 134, and/or Canadian Standards
Associations (CSA).

DISCLAIMER OF WARRANTIES
In the event the compressor is used
for the purpose of breathing air
application and proper in-line
safety and alarm equipment is not
simultaneously used, existing
warranties shall be voided, and
Campbell Hausfeld disclaims any
liability whatsoever for any loss,
personal injury or damage.

Record the Model No., Serial No. and
date of purchase located on the base
below the pump in the space below.

Model No. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Serial No. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Date of purchase _________________

Retain these numbers for future
r e f e r e n c e

.

Oil-Lubricated Compre s s o r s

DO NOT RETURN THE
PRODUCT TO THE
R E T A I L E R !

For parts, product & service information

visit

www.chpower.com

See Warranty on page 8 for important information about commercial use of this product.

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Oil-Lubricated Compre s s o r s; SPRAYING PRECAUTIONS; A s s e m b l y; HANDLE ASSEMBLY

2 Oil-Lubricated Compre s s o r s General SafetyI n f o rm a t i o n ( C o n t i n u e d ) 2 . Follow all local electrical and safety codes as well as in the US, NationalElectrical Code (NEC) andOccupational Safety and Health Act( O S H A ) . 3 . Only persons well acquainted with these rules of safe...

Page 3 - I n s t a l l a t i o n; L O C A T I O N; W I R I N G; Extension cords for; Side view of unit; Assembly

3 2 . Place lock washer on axle bolt. Then tighten nut securely to threaded partof axle bolt. 3 . Repeat procedure with other side. LUBRICATION THIS UNIT ISSHIPPED WITHOUT O I L ! Follow lubrication instructionsbefore operating compressor. Use oil shipped with the compressor. Do not use regular auto...

Page 4 - Operation

4 Operation • P r e ssure Switch - Auto/Off Switch (Figure7) - In the AUTO position, the compressor shuts off automatically whentank pressure reaches the maximumpreset pressure. In the OFF position, the compressor will not operate. This switchshould be in the OFF position when connecting or disconne...

Other Campbell Hausfeld Models

All Campbell Hausfeld Other