Campbell Hausfeld HU2000 - Manual
Campbell Hausfeld HU2000 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Portable Air Compressors; SPRAYING PRECAUTIONS; General Safety
- Page 3 – LOCATION
- Page 4 – Operation
- Page 6 – Notes
- Page 7 – Troubleshooting Chart
- Page 8 – limited warranty
- Page 9 – Description; Instructions D’Utilisation; Avertissement D’Air Respirable; DÉNÉGATION DES GARANTIES; Généralités Sur La; PROPOSITION 65 CALIFORNIE; MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie!
- Page 10 – Compresseurs D’Air Portatifs; PRÉCAUTIONS DE PULVÉRISATION
- Page 11 – ENDROIT
- Page 12 – Functionnement; Cordons Prolongateurs Pour Modèle De 120V/10 Ampères
- Page 14 – GRAISSAGE; ENTREPOSAGE
- Page 15 – Guide De Dépannage
- Page 16 – Garantie limitée
- Page 17 – Descripción; Manual de instrucciones; Advertencia sobre el; Generales de Seguridad; PROPOSICIÓN DE CALIFORNIA 65; Adjúntela a este manual o archívela en lugar seguro.
- Page 18 – Compresores de Aire Portátiles; Continuación
- Page 19 – Ensamblaje; Instalación; COLOCACIÓN; ALAMbRADO
- Page 20 – CONExION A TIERRA; Funcionamiento; Presostato; Cordones de extensión para los modelos de 120V/10 Amp
- Page 22 – Mantenimiento; LUbRICACION; ALMACENAMIENTO; Notas
- Page 23 – Guía de Diagnóstico de Averías (Continuación)
- Page 24 – Garantía limitada
Oilless Compressors
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
Portable oilless air compressors are for
home and workshop use. Cleaning or
replacement of the inlet filter on all
models and draining moisture from the
air receivers are required maintenance.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
warning indicates
a potentially
hazardous situation which, if not avoided,
coulD result in death or serious injury.
caution indicates a
potentially
hazardous situation which, if not avoided,
MAY result in minor or moderate injury.
Notice indicates
important
information, that if not followed, MAY
cause damage to equipment.
Unpacking
When unpacking unit, inspect carefully
for any damage that may have occurred
during transit.
Make sure any loose
fittings, bolts, etc., are tightened before
putting unit into service. In case of
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
assistance. Have the serial number,
model number, and part
s list (with
missing parts circled) before calling.
Operating Instructions
HM7000 and HU2000
Breathable Air warning
This compressor/pump is not
equipped and should not be
used “as is” to supply breathing
quality air. For any application of
air for human consumption, the
air compressor/pump will need
to be fitted with suitable in-line
safety and alarm equipment.
This additional equipment is
necessary to properly filter
and purify the air to meet
minimal specifications for Grade
D breathing as described in
Compressed Gas Association
Commodity Specification G 7.1
- 1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is
used for the purpose of breathing
air application and proper in-line
safety and alarm equipment is
not simultaneously used, existing
warranties shall be voided, and
Campbell Hausfeld disclaims any
liability whatsoever for any loss,
personal injury or damage.
General Safety
CALIFORNIA PROPOSITION 65
This product or
its power cord may
contain chemicals, including lead, known
to the State of california to cause cancer
and birth defects or other reproductive
harm. wash hands after handling.
You can
create
dust when you cut, sand,
drill or grind materials such
as wood, paint, metal,
concrete, cement, or other
masonry. This dust often contains
chemicals known to cause cancer, birth
defects, or other reproductive harm.
wear protective gear.
IN628800AV 1/09
GENERAL SAFETY INFORMATION
Air compressors are utilized in a variety
of air system applications. Because air
compressors and other components
(material pump, spray gun, filters,
lubrications, hoses, etc.) used make up
a high pressure pumping system, the
following safety precautions should be
observed at all times. Only persons well
acquainted with these rules of safe
operation should be allowed to use the
air compressor.
All electrical work
should be done by a
qualified (licensed or certified)
electrician. on a properly wired circuit,
the black wires supply a voltage
potential even when the unit is off.
© 2009 Campbell Hausfeld/Scott Fetzer
For parts, product & service information
visit
www.chpower.com
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
See Warranty on page 8 for important information about commercial use of this product.
Record the Model No., Serial No. and
date of purchase located on the base
below the pump in the space below.
Model No.
____________________
Serial No.
____________________
Date of purchase _________________
Retain these numbers for future
reference.
STOP!
DO NOT RETURN
THE PRODUCT TO
THE RETAILER!
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Portable Air Compressors 2 1. Read instruction manuals for each component carefully, before attempting to assemble, disassemble or operate your particular system. 2. Wear safety glasses and use hearing protection when operating the pump or unit. 3. Do not stand on or use the pump or unit as a handho...
Gauge of Cord 16 14 10 Extension cords for 120V/10 Amp Unit Length of Cord (ft) 25 50 100 HM7000 and HU2000 3 Assembly FOOT ASSEMbLY (FIGURE 1) Foot assembly kit includes: - 1 rubber foot - 1 bolt - 2 washers - 1 nut WHEEL ASSEMbLY (FIGURE 2) Wheel assembly kit includes:- 2 wheels*- 2 axle bolts*- 2...
4 Portable Air Compressors shock by providing an escape wire for electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. Plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordin...