Campbell Hausfeld EZ5000 - Manual

Campbell Hausfeld EZ5000

Campbell Hausfeld EZ5000 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 2 – General Safety; – To; GROUNDING INSTRUCTIONS; DANGER; NOTICE; CAUTION; WARNING; Gauge of Cord; Table 1 – Extension Cords for 120V/15 Amp Unit
  • Page 3 – • Do not smoke in the spray area.
  • Page 5 – TOOLS REQUIRED; Screwdriver; PREPARATION; turn the unit to the Prime
  • Page 6 – When Painting Outside; Painting Fences
  • Page 7 – Doors; Step 1 – Priming; More on Walls
  • Page 8 – Setting The Pressure
  • Page 9 – much as possible. If you still have; Spraying; INCORRECT
  • Page 10 – Coatings That Clean Up With Water.
  • Page 12 – Maintenance Chart
  • Page 13 – Troubleshooting Chart; = Service Center Recommended
  • Page 15 – “Force Feeding” Pump
  • Page 16 – Description; Suction bell and filter; See product insert for spray tips and accessories
  • Page 19 – Spécifications; Se reporter au décalque du; Déballage; Sécurité générale; AVERTISSEMENT; Voir la Garantie à la page 35 pour de l’information importante sur; MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie!
  • Page 20 – INSTRUCTIONS DE MISE À TERRE; AVIS; ATTENTION; Calibre du cordon
  • Page 23 – Installation; PRÉPARATION
  • Page 24 – En peignant à l’intérieur
  • Page 26 – Régler la pression
  • Page 28 – Revêtements qui se nettoient à l’eau
  • Page 30 – Tableau d’entretien
  • Page 31 – Tableau de dépannage
  • Page 35 – Voir la documentation du produit pour les buses de
Loading the manual

Operating Instructions & Parts Manual

EZ5000 Series

Please read and save these instructions. Read carefully before attempting to assemble,
install, operate or maintain the product described. Protect yourself and others by
observing all safety information. Failure to comply with instructions could result in per-
sonal injury and/or property damage! Retain instructions for future reference.

B U I L T T O L A S T

The
HousePainter

®

IN423200AV 3/04

© 2004 Campbell Hausfeld/

Scott Fetzer

For parts, product & service information

visit

www.chpower.com

Specifications

Motor . . . . . . . 1/4 HP, 120 Volt, 5 Amp

Delivery . . . . . . . 0.2 gallon per minute

Max. Pressure . . . . . . . . . . . . . . 2500 psi

Refer to product decal for exact

specifications.

FOR HOUSEHOLD USE ONLY

Description

Airless paint sprayers are capable of
spraying a variety of latex and oil-
based paints, as well as stains, preserv-
atives and other non-abrasive finishes.
The coatings that can be sprayed will
vary depending on the sprayer.

Unpacking

After unpacking the unit, inspect care-
fully for any damage that may have
occurred during transit. Make sure to
tighten all connection points before
putting into service. There will be
some lubricant in the sprayer head
from the testing process. Spray a short
burst onto a practice surface after fill-
ing the canister with paint. This will
clear the lubricant without affecting
the paint job or the coating.

General Safety

This manual contains information that
is very important to know and under-
stand. This information is provided for
SAFETY and to PREVENT EQUIPMENT
PROBLEMS. To help recognize this
information, observe the following
symbols.

Danger indicates
an imminently

hazardous situation which, if not
avoided, WILL result in death or seri-
ous injury.

Warning indicates
a potentially haz-

ardous situation which, if not avoided,
COULD result in death or serious injury.

!

WARNING

!

DANGER

REMINDER: Keep your dated proof of purchase for warranty purposes!

Attach it to this manual or file it for safekeeping.

See Warranty on page 17 for important information about

commercial use of this product.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - General Safety; – To; GROUNDING INSTRUCTIONS; DANGER; NOTICE; CAUTION; WARNING; Gauge of Cord; Table 1 – Extension Cords for 120V/15 Amp Unit

2 Operating Instructions & Parts Manual www.chpower.com General Safety (Cont.) Caution indicates a potentially haz- ardous situation which, if not avoided,MAY result in minor or moderateinjury. Notice indicates important infor- mation that, if not followed, maycause damage to the equipment. IMPO...

Page 3 - • Do not smoke in the spray area.

3 EZ5000 Series www.chpower.com General Safety (Cont.) Extension Cords: Use only a 3-wire extension cordthat has a 3-blade grounding plug,and a 3-slot receptacle that acceptsthe plug on the product. Make surethe extension cord is not damaged.When using an extension cord, besure to use one heavy enou...

Page 5 - TOOLS REQUIRED; Screwdriver; PREPARATION; turn the unit to the Prime

Set-Up TOOLS REQUIRED Screwdriver Two adjustable wrenches – or two 3/4” open-end wrenches –or any combination of the twotypes Extension cord – see Table 1 on Page 2. Remove all components from thebox. Remove the cap from the hoseadapter and attach one end of thehigh pressure hose to the sprayer(see ...

Other Campbell Hausfeld Models

All Campbell Hausfeld Other