Camden CX-33 - Installation Manual

Camden CX-33

Camden CX-33 – Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 2 – CX-33 Advanced Logic Relay Installation Instructions; Table 1
  • Page 3 – Programmable Inputs; For example, the mode is set to Mode 7.; Wet Input; Control Input; Section 3A; Refer to
  • Page 4 – Section 3B; Section 3C; Section 3D; the
  • Page 5 – Section 3E; Section 3F; Section 3G
  • Page 6 – provided on the relay outputs – they are dry contacts).; Section 3H; Diagram 8; Section 3J; Diagram 9; Optional Switching Network:; System Inspection Instructions
  • Page 7 – Section 3L; Section 3M
  • Page 8 – Section 3P; It is NOT recommended to add the “Delay-on-activate”; Section 3Q
  • Page 15 – iri; am
  • Page 25 – LA
  • Page 26 – oc
Loading the manual
Page 1

Page 1 of 28

Section 1

General Description

The CX-33 is the latest generation multi-purpose logic control.
It is designed to be versatile yet user friendly with easy to
understand terminology and adjustments. The 15 different
operating modes ensure it will be useful in nearly every
automatic door or security application.

A total of 5 inputs (4 dry, and one wet or powered) allow for
more flexibility in wiring to different types of activating devices.
The wet or powered input is useful when connecting to
3-terminal radio receivers, telephone entry systems panels, or
for connecting to motors when used as a Lock-out Relay.

The 3 buttons for mode selection, including separate UP and

DOWN buttons, offer fast and easy programming. The large
3-segment display is the easiest to view and understand in
the industry.

A total of 3 heavy-duty 3 amp relays allow for varied
sequencing applications. For example, in restroom use, the
third relay is ideal for “Occupied” or “In Use” signage.
(Note: ouputs are dry, not powered.)

Section 2

Installation

IMPORTANT: Do not apply power to the unit until you

have read the instructions fully and made the required

adjustments.

Mounting

The CX-33 should be mounted in a clean dry location out
of direct contact with the elements. Suitable locations
include inside a metal enclosure, operator header, or above
a false ceiling.

The Display & LED’s are visible through the clear plastic
case, which also has cutouts for the programming buttons
and terminal strips. Once the unit has been wired and
adjusted, it may be tucked up into the operator header or
affixed using the supplied Velcro or 2 sheet metal screws.

Wiring

Wiring of this unit is dependent on the mode desired,
however the following commonalities apply:

The unit will operate on 12 or 24 volts, AC or DC. Connect to
Terminals 1 & 2, which are non-polarity sensitive.

NOTE: We

highly

recommend the use of a regulated power

supply when powering equipment in certain modes such as
the barrier-free washroom application where the strike power
may be maintained from a few minutes to many hours. We
offer a low-cost board-only regulated power supply - CX-PS13,
which will supply clean, filtered & regulated 12 or 24VDC
power for the strike and CX-33.

CX-33 Advanced Logic Relay

Installation Instructions

Firmware Ver. 3.2

1- #6 x 3/4” Self Tapping Screws
1- 1 1/2” x 1 1/2” Velcro
1- 50

Ω

, 1W Resistor

This Package Includes:

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Camden
Model
CX-33
Document type
Installation Manual
Language(s)
English
Pages
28
Format
PDF

Summary

Page 2 - CX-33 Advanced Logic Relay Installation Instructions; Table 1

Page 2 of 28 General Programming Instructions To enter the program mode, press the MENU button. The current operating mode will display. Each time you press Use the UP and DOWN buttons to change the value of each MENU item. (Holding a button down will increase the speed of scrolling). If you do not ...

Page 3 - Programmable Inputs; For example, the mode is set to Mode 7.; Wet Input; Control Input; Section 3A; Refer to

Page 3 of 28 CX-33 Advanced Logic Relay Installation Instructions Programmable Inputs The Dry and Wet Inputs are programmable to accept either a Normally Open contact or a Normally Closed contact. Table 1 shows the default settings for all modes. Changes made to the inputs are saved and will remain ...

Page 4 - Section 3B; Section 3C; Section 3D; the

Page 4 of 28 CX-33 Advanced Logic Relay Installation Instructions Section 3B 2 Door Timed Airlock (Mode 2) Utilizing door position switches (Camden CX-MDC or equivalent), this mode ensures that only one door in an airlock will be open at a time. Each output hold time is adjustable from 1 – 50 second...

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.