Page 2 - TABLE OF CONTENTS
INST ALLA TION MANUAL TABLE OF CONTENTS 2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6 Cleaning and Maintenance . . . . . . . . . . . . . . . . . 7 MotorsGrease FiltersNon-Ducted Recirculation F...
Page 3 - SAFETY; READ AND SAVE THESE INSTRUCTIONS; INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.; WARNING
INSTALLATION MANUAL SAFETY 3 READ AND SAVE THESE INSTRUCTIONS ! Intended for domestic cooking only ! INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. In U.S.A., register your range hood online at www.broan-nutone.com In Canada, register your Broan range hood online at www.broan.ca or register your NuTon...
Page 4 - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:; CAUTION
INST ALLA TION MANUAL SAFETY 4 ! WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high hea...
Page 5 - Operation; Operate the hood as follows:; BLOWER SWITCH; Turns blower on to LOW speed.; II; Turns blower on to HIGH speed.; LIGHT SWITCH; BCSEK1 SERIES; FILTER CLEANING REMINDER; short lapse of time, and then resume to LOW speed.; LIGHT BUTTON
INSTALLATION MANUAL OPERA TION 5 Operation Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and fresher. Operate the hood as fol...
Page 6 - CLEANING AND MAINTENANCE; Cleaning and Maintenance; Avoid when choosing a detergent:; bleach
INST ALLA TION MANUAL OPERA TION 6 ON LIGHTING/LIGHT INTENSITY CHANGE Press this button to turn on the lights at the last saved intensity; the light icon appears on right side of LCD screen and the number of dots below it shows which light intensity is on (one dot for LOW, two dots for MEDIUM and th...
Page 7 - TION; Install Ductwork (Ducted Installations Only)
INSTALLATION MANUAL CLEANING AND MAINTENANCE 7 Cleaning and Maintenance Proper maintenance of the Range Hood will assure proper performance of the unit. MOTORS The motors are permanently lubricated and never need oiling. If the motor bearings make excessive or unusual noise, replace the motor with t...
Page 8 - INST; Contents; Make sure that the following items are included:; Maximum Duct Lengths Recommended; * Standard elbows with 1” internal radius.
INST ALLA TION MANUAL INST ALLA TION 8 Recommended Tools and Accessoriesfor Installation • Measuring tape • Phillips screwdriver no. 2 • Nutdriver or socket 11/32” • Flat blade screwdriver (to open knockout holes) • Drill, 1/8” drill bit and 1½” hole saw (to mark holes for ducting and cut electrical...
Page 9 - Prepare the Hood; from the hood by pushing down
INSTALLATION MANUAL INSTALLA TION 9 Contents Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer. Make sure that the following items are included: BCDJ1 Series: NCDJ1 Series: (1) 3¼” X 10” D AMPER A SSEMBLY (1) P ARTS B AG *...
Page 10 - NON-DUCTED INSTALLATION ONLY
INST ALLA TION MANUAL INST ALLA TION 10 B C Prepare the Hood 1 ] If present, remove all protective polyfilm from the hood and/or parts. 2 ] For BCDJ1 Series only: Remove 7” Round Duct Plate from top/back of hood (see illustration below). Keep the screws for further use. For BCDJ Series and NCDJ1 Ser...
Page 11 - DUCTED INSTALLATION ONLY; TIP; connection with the house duct work.; and
INSTALLATION MANUAL INSTALLA TION 11 6 ] Remove Electrical Power Cable Knockout from top (vertical wiring) or back (horizontal wiring)of hood. For knockout removed from back of hood, install an appropriate strain relief, 1/2” diameter(not included). For knockout removed from top of hood, the strain ...
Page 12 - Prepare the Hood Location; EZ1 one-person installation system; If replacing a hood and plan to use; Measure and mark the hood center line on cabinet bottom.
INST ALLA TION MANUAL INST ALLA TION 12 DUCTED INSTALLATION ONLY TIP : Inser t a small length of duct over the 3¼” x 10” damper assembly (for rectangular ducting) or 7” round (for round ducting) and seal the joint using aluminum foil duct tape to ease connection with the house duct work. 8 ] Remove ...
Page 13 - location on template.
INSTALLATION MANUAL INSTALLA TION 13 Prepare the Hood Location NOTE: Before star ting installation, read all the steps of these instructions.Use the illustration below to identify your kitchen cabinet type. EZ1 One-person installation system EZ1 installation is designed for use with kitchen cabinets...
Page 14 - Use a pencil to mark 3 holes.
INST ALLA TION MANUAL INST ALLA TION 14 FRAMED CABINET 7/64” X Y Z Refer to the marking on brackets to determine the correct installation side and orientation. Mate the corresponding bracket to the cabinet side frame, while placing rear end of bracket against the wall. Use a pencil to mark 3 hole...
Page 15 - While holding the hood
INSTALLATION MANUAL INSTALLA TION 15 [ \ 7/64” X 3 X Y Z Refer to the marking on brackets to determine the correct installation side and orientation. Align the corresponding bracket to the cabinet side, while placing rear end of bracket against the wall. Draw a line on the outer edge of the brack...
Page 16 - ] For framed cabinet; , secure the hood to the cabinet using 4 no. 8 x 5/8” round head wood
INST ALLA TION MANUAL INST ALLA TION 16 A C B D HORIZONTAL EXHAUST INSTALLATION VERTICAL EXHAUST INSTALLATION AND NON-DUCTED INSTALLATION ONLY OTE: N The following procedure applies to both frame or frameless cabinet installations. Install the Hood (EZ1 Bracket) 1 ] Run house power cable between ser...
Page 17 - Standard Installation (without EZ1 Brackets)
INSTALLATION MANUAL INSTALLA TION 17 FRAMEDCABINET FRAMELESSCABINET 7 ] For framed cabinet , secure the hood to the EZ1 brackets using four (4) no. 8-18 x 1/2” metal screws (included in parts bag). Insert two (2) screws per side, in the slots (as shown in insets on illustration below). 8 ] For frame...
Page 19 - Connect the Wiring; Install the Filters; Ducted Installation Only:; Re-install grease filters removed in step
INSTALLATION MANUAL INSTALLA TION 19 Install the Hood (Standard Installation) 1 ] Run house power cable between service panel and hood location. For hood with power cable access located on back of hood, run the house power cable into the hood through the strain relief previously installed in step 6 ...
Page 20 - WIRING DIAGRAMS
INST ALLA TION MANUAL INST ALLA TION 20 Connect the Wiring 1 ] Connect House Power Cable to range hood wiring: BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw. 2 ] Reinstall the blower cover plate (shaded par t on illustration above) using the lock nut and the 7 screws...
Page 21 - ontr; BCDF1 SERIES
INSTALLATION MANUAL WIRING DIAGRAM 21 BK G/Y BK 24 V Class 2 W R BL BL R R BK ( H ) BK R ( L ) O ( M ) BK ( H ) G/Y J2 5 4 1 6 J4 J1 1 2 3 4 5 3 4 5 6 7 1 2 3 2 1 4 LCD INTE RFA CE Powe r, M oto r Transfo rmer LED O ( M ) O (M ) BK ( H ) R ( L ) R ( L ) G/Y Co ntrol Bo ard ADA O ve rri de W W W W Tr...
Page 22 - SERVICE P
INST ALLA TION MANUAL SERVICE P AR TS 22 BCDJ1 AND NCDJ1 SERIES K EY NO . P ART NO . D ESCRIPTION Q UANTITY 30" B LACK ** 30" S TAINLESS 30" W HITE 1 S97020029 R ECIRCULATION COVER PLATE , B LACK ( INCLUDING SCREWS ) 1 S97020030 R ECIRCULATION COVER PLATE , W HITE ( INCLUDING SCREWS ) 1 ...
Page 25 - ARRANTY
INSTALLATION MANUAL SERVICE P AR TS 25 K EY NO . P ART NO . D ESCRIPTION Q UANTITY 36" B LACK 36" S TAINLESS 36" W HITE 42" S TAINLESS 1 S97020029 R ECIRCULATION COVER PLATE , B LACK ( INCLUDING SCREWS ) 1 S97020030 R ECIRCULATION COVER PLATE , W HITE ( INCLUDING SCREWS ) 1 S97020031...
Page 26 - Séries : BCDF1 et BCSEK1; MANUEL D’INSTALLATION,
INST ALLA TION MANUAL W ARRANTY 26 Limited Warranty Warranty Period and Exclusions: Broan-NuTone LLC and Venmar Ventilation ULC (either being the “Company”) warrants to the original consumer purchaser of its product (“you”) that the product (the “Product”) will be free from material defects in the P...