Page 2 - SAFETY RULES; TABLE OF CONTENTS; Hazard Symbols and Meanings; SAVE THESE INSTRUCTIONS
SAFETY RULES 2 TABLE OF CONTENTS Safety Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4Features and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7Operation . . . . . . ...
Page 3 - WARNING; NEVER use in the home
SAFETY RULES 3 • This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications. • Failure to use the appropriate U. S. Coast Guard approved generator could result in death or serious injury and/orproperty damage. WARNING • Operate generator ONLY ou...
Page 5 - FEATURES AND CONTROLS; KNOW YOUR GENERATOR
FEATURES AND CONTROLS 5 KNOW YOUR GENERATOR Read this Operator’s Manual and safety rules before operating your generator.Compare the illustrations with your generator, to familiarize yourself with the locations of various controls andadjustments. Save this manual for future reference. 120 Volt AC, 2...
Page 6 - ASSEMBLY; Unpacking the Generator
ASSEMBLY 6 ASSEMBLY Your generator requires some assembly and is ready foruse after it has been properly serviced with therecommended oil and fuel. If you have any problems with the assembly of yourgenerator, please call the generator helpline at1-800-743-4115. If calling for assistance, please have...
Page 7 - BEFORE STARTING THE; Add Engine Oil; Add Fuel; CAUTION
ASSEMBLY 7 BEFORE STARTING THE ENGINE Add Engine Oil • Place generator on a level surface. • Use a long neck funnel when adding or changing oil. • Refer to engine operator’s manual and follow oil recommendations and instructions. NOTE: Check oil often during engine break–in. Refer toengine operator’...
Page 8 - OPERATION; USING THE GENERATOR; Special Requirements; Generator Clearance
OPERATION 8 USING THE GENERATOR System Ground The generator has a system ground that connects thegenerator frame components to the ground terminals onthe AC output receptacles. The system ground is connectedto the AC neutral wire (see “Equipment Description”,earlier in this manual). Special Requirem...
Page 9 - OPERATING THE; Starting the Engine
OPERATION 9 OPERATING THE GENERATOR Starting the Engine Disconnect all electrical loads from the generator. Followthese start instruction steps in numerical order: 1. Make sure unit is on a level surface. IMPORTANT: Failure to start and operate unit on a levelsurface will cause the unit not to start...
Page 10 - Stopping the Engine; Move fuel valve to “Off” position.; RECEPTACLES; Receptacle
OPERATION 10 Stopping the Engine 1. Turn off and unplug all electrical loads from generatorpanel receptacles. NEVER start or stop engine withelectrical devices plugged in and turned on. 2. Let engine run at no–load for 30 seconds to stabilizeinternal temperatures of engine and alternator. 3. Turn en...
Page 11 - GENERATOR; Capacity
OPERATION 11 DON'T OVERLOAD GENERATOR Capacity You must make sure your generator can supply enoughrated (running) and surge (starting) watts for the items youwill power at the same time. Follow these simple steps:1. Select the items you will power at the same time. 2. Total the rated (running) watts...
Page 12 - SPECIFICATIONS AND MAINTENANCE; SPECIFICATIONS
SPECIFICATIONS AND MAINTENANCE 12 SPECIFICATIONS Starting Wattage . . . . . . . . . . . . . . . . . . . . . . . . .8,500 wattsWattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5,500 wattsAC Load Current: At 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . . . . .45.8 Amps...
Page 13 - STORAGE; Generator Storage; DANGER
STORAGE 13 STORAGE The generator should be started at least once every sevendays and allowed to run at least 30 minutes. If this cannotbe done and you must store the unit for more than30 days, use the following guidelines to prepare it forstorage. Generator Storage • Clean the generator as outlined ...
Page 14 - TROUBLESHOOTING; Problem; Generator lacks power.
TROUBLESHOOTING 14 TROUBLESHOOTING Problem Cause Solution Generator is running, but no ACoutput is available. 1. Circuit breaker is open. 2. Poor connection or defective cordset. 3. Connected device is bad. 4. Fault in generator. 1. Reset circuit breaker. 2. Check and repair. 3. Connect another devi...
Page 15 - LIMITED WARRANTY
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC PORTABLE GENERATOR OWNER WARRANTY POLICY LIMITED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the portable generator that isdefective in material or workmanship or both. Transportation ...
Page 16 - RÈGLES DE SÉCURITÉ; TABLE DES MATIÈRES; Symboles de Danger et Moyens; AVERTISSEMENT; VEUILLEZ CONSERVER CES INSTRUCTIONS
RÈGLES DE SÉCURITÉ 16 TABLE DES MATIÈRES Règles de Sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-18Fonctions et Commandes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Assemblage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 19 - FONCTIONS ET COMMANDES; CONNAISSEZ VOTRE GÉNÉRATEUR
FONCTIONS ET COMMANDES 19 CONNAISSEZ VOTRE GÉNÉRATEUR Lire ce manuel de l'utilisation et les régles de sécurité avant de faire marcher votre générateur.Comparez les illustrations avec votre générateur pour vous familiariser avec l'emplacement des diverses commandes et réglages.Gardez ce manuel pour ...
Page 20 - ASSEMBLAGE; Enlever le générateur de la boite
ASSEMBLAGE 20 ASSEMBLAGE Votre générateur exige que quelque assemblée et soit prêt pourl'usage après il a été convenablement entretenu avec le pétrole etle carburant recommandés. Si vous avez n'importe quels problèmes avec l'assemblée de votregénérateur, s'il vous plaît appeler le helpline de généra...
Page 21 - AVANT LE DÉMARRAGE DU; Ajoutez de l'huile à moteur; ATTENTION
ASSEMBLAGE 21 AVANT LE DÉMARRAGE DU MOTEUR Ajoutez de l'huile à moteur • Mettre le générateur sur une surface à niveau. • Utilisez un entonnoir lorsque vous ajoutez ou changez l'huile. • Reportez-vous au manuel d'utilisation du moteur et suivez lesdirectives et les recommandations relatives à l'huil...
Page 22 - OPÉRATION; UTILISATION DE LA; Mise à la terre du système; Branchement au système électrique d'un
OPÉRATION 22 UTILISATION DE LA GÉNÉRATRICE Mise à la terre du système La génératrice possède une mise à la terre du système quiraccorde les éléments du cadre de la génératrice aux bornes demise à la terre des prises de sortie C.A. La mise à la terre dusystème est raccordée au fil neutre C.A. (voir “...
Page 23 - UTILISATION DU GÉNÉRATEUR; Démarrage du Moteur
OPÉRATION 23 UTILISATION DU GÉNÉRATEUR Démarrage du Moteur Déconnectez toutes les charges électriques du générateur. Suivezces étapes d'instructions de démarrage dans l'ordre numérique:1. Assurez-vous que la génératrice se trouve sur une surface deniveau. IMPORTANT: Si la génératrice n'est pas sur u...
Page 24 - PRISES DE COURANT; Courant Double
OPÉRATION 24 Arrêt du Moteur 1. Débrancher toutes les charges électriques des prises dugénérateur. NE JAMAIS mettre en route ou arrêter le moteuralors que les appareils électriques sont branchés et en marche. 2. Laissez le moteur tourner à vide pendant deux minutes pourstabiliser les températures in...
Page 25 - NE SURCHARGEZ PAS; Capacité; Gestion de la Consommation
OPÉRATION 25 NE SURCHARGEZ PAS GÉNÉRATEUR Capacité Vous devez vous assurer que votre générateur puisse fournirsuffisamment de puissance nominale (appareil en marche) et desurtension (au démarrage) pour les appareils que vous voulezalimenter en même temps. Suivez ces étapes simples: 1. Sélectionnez l...
Page 27 - ENTREPOSAGE ET DÉPANNAGE; DÉPANNAGE; Remisage du Moteur; PROBLÈMES
ENTREPOSAGE ET DÉPANNAGE 27 DÉPANNAGE Remisage du Moteur Voir les instructions sur la manière de remiser correctement lemoteur dans le manuel de l’utilisation du moteur. Autres Idées de Remisage • Rangez toujours l'unité avec la valve d'essence sur la positon“Off” (Arrêt) (Figure 15, ci-dessus). • P...