ExpWave 240B Secure Outdoor Ethernet Radio Link Copyright iii Copyright ExpWave 240B Secure Outdoor Ethernet Radio Link Copyright © 2002 by ZyXEL Communications Corporation. The contents of this publication may not be reproduced in any part or as a whole, transcribed, stored in a retrieval system, t...
ExpWave 240B Secure Outdoor Ethernet Radio Link iv FCC Statement Federal Communications Commission (FCC) Interference Statement This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accep...
ExpWave 240B Secure Outdoor Ethernet Radio Link Information for Canadian Users v Information for Canadian Users The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operation, and safety requirement...
ExpWave 240B Secure Outdoor Ethernet Radio Link vi Canadian Users Product installation requirements 1. The ExpWave 240B can only be installed by a licensed installer; training and access to technical requirements will be provided through the user guide and through training done by the business partn...
ExpWave 240B Secure Outdoor Ethernet Radio Link Warranty vii ZyXEL Limited Warranty ZyXEL warrants to the original end user (purchaser) that this product is free from any defects in materials or workmanship for a period of up to two years from the date of purchase. During the warranty period, and up...
ExpWave 240B Secure Outdoor Ethernet Radio Link viii Customer Support Customer Support When you contact your customer support representative please have the following information ready: ♦ ExpWave 240B Model and serial number. ♦ Information in Menu 24.1 –System Information. ♦ Warranty Information. ♦ ...
ExpWave 240B Secure Outdoor Ethernet Radio Link Table of contents ix Table of Contents Copyright ...................................................................................................................................................................... iii Federal Communications Commissio...
ExpWave 240B Secure Outdoor Ethernet Radio Link Table of contents xi 11.4.1 WAN DHCP ........................................................................................................................... 11-6 Chapter 12 Firmware and Configuration File Maintenance ..................................
ExpWave 240B Secure Outdoor Ethernet Radio Link xii Table of Contents 14.3 SNMP .......................................................................................................................................................14-1 14.4 DNS ..........................................................
ExpWave 240B Secure Outdoor Ethernet Radio Link List of Figures/Tables xiii List of Figures Figure 2-1 Front view of ExpWave ....................................................................................................................... 2-1 Figure 2-2 Bottom view of ExpWave ....................
ExpWave 240B Secure Outdoor Ethernet Radio Link List of Figures/Tables xv List of Tables Table 1-1 Specification of ExpWave 240B ......................................................................................................... 1-3 Table 2-1 Connectors of bottom .................................
ExpWave 240B Secure Outdoor Ethernet Radio Link Getting to Know Your ExpWave 1-1 Chapter 1 Getting to Know Your ExpWave This chapter introduces the main features and applications of the ExpWave. 1.1 Introduction to the ExpWave 240B The ZyXEL ExpWave 240B (ExpWave 240B) is a Wireless Bridge/Router fo...
ExpWave 240B Secure Outdoor Ethernet Radio Link 1-2 Getting to Know Your ExpWave IP Policy Routing IP Policy Routing provides a mechanism to override the default routing behavior and alter packet forwarding based on the policies defined by the network administrator. SNMP SNMP (Simple Network Managem...
ExpWave 240B Secure Outdoor Ethernet Radio Link Getting to Know Your ExpWave 1-3 1.5 Applications of the ExpWave 240B With ExpWave 240B Secure Wireless Point to Point Solution, you can extend and enhance your network virtually overnight without natural or man-made barriers to overcome. Easy installa...
ExpWave 240B Secure Outdoor Ethernet Radio Link Hardware Installation 2-1 Chapter 2 Hardware Installation This chapter explains the physical ports and how to connect the hardware of ExpWave. 2.1 Hardware Description The content of the ExpWave 240B are described below. 1. The outdoor unit The outdoor...
ExpWave 240B Secure Outdoor Ethernet Radio Link 2-2 Hardware Installation Figure 2-3 Top view of ExpWave The major interfacse on the top of EXPWAVE 240B is the RF antenna connector with special water proof. Table 2-2 describes the antenna connector. Table 2-2 Antena connector of the top Function Lab...
ExpWave 240B Secure Outdoor Ethernet Radio Link Hardware Installation 2-3 Figure 2-6 Front view of flat panel antenna Besides those above antenna types, the 24 dBi parabolic grid antenna is also available which could be used for longer distance communication for those areas without regulation limita...
ExpWave 240B Secure Outdoor Ethernet Radio Link 2-4 Hardware Installation 6. Grounding wire The grounding wire is used to provide the grounding path for the outdoor unit to minimize the impact of lightening and surge. The physical appearance of the grounding wire is shown below. Figure 2-10 Groundin...
ExpWave 240B Secure Outdoor Ethernet Radio Link Hardware Installation 2-5 Figure 2-13 Antenna Alignment Kit 10. CAT-5 Straight-through Ethernet cable The CAT-5 cable is 2m in length. This cable is used to connect the network/power injector and the CPE. The picture of this cable is shown below. Figur...
ExpWave 240B Secure Outdoor Ethernet Radio Link 2-6 Hardware Installation Figure 2-16 Physical Installation of ExpWave with Omni-directional antenna Figure 2-17 Physical Installation of ExpWave with flat panel antenna 2.3 Installation Procedure The installation procedure of ExpWave is described as b...
ExpWave 240B Secure Outdoor Ethernet Radio Link Hardware Installation 2-7 1. The whole installation procedure begins from the indoor to the outdoor installation. 2. Choose an appropriate place for the network/power injector. You might hang it on the wall or just place it on the desk. 3. Connect the ...
ExpWave 240B Secure Outdoor Ethernet Radio Link Initial Setup 3-1 Chapter 3 Initial Setup This chapter explains how to perform the initial ExpWave setup and gives an overview of SMT menus. 3.1 Network Topology Planning The ExpWave is designed for business companies to build up a secure Inter-buildin...
ExpWave 240B Secure Outdoor Ethernet Radio Link 3-2 Initial Setup Bridge Mode Figure 3-2 Network Topology in Bridge Mode The basic configurations in bridge mode are described as below: Step 1. First set AP to Bridge mode. In AP’s Menu 1, set IP Routing = Bridge Mode. Figure 3-3 Menu 1 – Bridge Mode ...
ExpWave 240B Secure Outdoor Ethernet Radio Link Initial Setup 3-3 Figure 3-5 Menu 5 – Wireless Setup Step 4. In AP’s Menu 6, set AC1 Operation mode= Enabled, Pre_Share Key= 951753258, IP= 192.168.80.155, Network Mask= 255.255.255.0, MAC Address= 00:02:CF:13:46:79 (the same as AC1’s MAC Address) Figu...
ExpWave 240B Secure Outdoor Ethernet Radio Link 3-4 Initial Setup Figure 3-7 Menu 5 – Access Client Wireless Setup Step 6. in AC, Use Menu 24-8 into CI command mode, type ip ping 192.168.80.217 Figure3-8 IP Ping Step 7. In the Menu 24-1, it will show the connection status between AP and AC Router Mo...
ExpWave 240B Secure Outdoor Ethernet Radio Link Initial Setup 3-5 Figure 3-11 TCP/IP and DHCP Ethernet Setup Step 3. In AP’s Menu 5, set ESSID= Wireless and Channel ID. Figure 3-12 Wireless Setup Step 4. In AP’s Menu 6, set AC1 Operation mode= Enabled, Pre_Share Key= 951753258, IP=192.168.223.1, Net...
ExpWave 240B Secure Outdoor Ethernet Radio Link 3-6 Initial Setup Step 5. Set DHCP to server and Client IP Pool Starting Address like 192.168.223.33. You can also setting the Size of Client IP Pool, Primary DNS and Secondary DNS Server. Figure 3-14 AC1 LAN DHCP Setup Step 6. Now set AC with the same...
ExpWave 240B Secure Outdoor Ethernet Radio Link Initial Setup 3-7 At this point, you should have connected the console port, the RF (Antenna) port, the LAN port, and the power port to the appropriate devices or lines. While connecting power adaptor into outlet, the PWR LED of your Network/Power inje...
ExpWave 240B Secure Outdoor Ethernet Radio Link 3-8 Initial Setup OPERATION KEYSTROKES DESCRIPTION keys the next field, respectively. Entering information Fill in, or press [SPACE BAR], then press [ENTER] to select from choices. You need to fill in two types of fields. The first requires you to type...
ExpWave 240B Secure Outdoor Ethernet Radio Link Initial Setup 3-9 NO. MENU TITLE FUNCTION 22 SNMP Configuration Use this menu to configure SNMP-related parameters. 23 System Password Change your password in this menu (recommended). 24 System Maintenance From displaying system status to uploading fir...
ExpWave 240B Secure Outdoor Ethernet Radio Link General Setup 4-1 Chapter 4 Menu 1 - General Setup Menu 1 - General Setup contains administrative and system-related information. 4.1 System Name System Name is for identification purposes. ZyXEL recommends you enter your computer’s “Computer name”. • ...
ExpWave 240B Secure Outdoor Ethernet Radio Link Wireless Setup 5-1 Chapter 5 LAN Setup This chapter describes how to configure the LAN using Menu 3 — LAN Setup . 5.1 Introduction From the main menu, enter 3 to open Menu 3 – LAN Setup . Figure 5-1 Menu 3 — LAN Setup 5.2 LAN Port Filter Setup This men...
ExpWave 240B Secure Outdoor Ethernet Radio Link 5-2 Wireless Setup 5.3.1 Factory LAN Defaults The LAN parameters of the ExpWave are preset in the factory with the following values: 1. IP address of 192.168.1.1 with subnet mask of 255.255.255.0 (24 bits). 2. DHCP server enabled with 32 clients IP add...
ExpWave 240B Secure Outdoor Ethernet Radio Link Wireless Setup 5-3 The subnet mask specifies the network number portion of an IP address. Your ExpWave will compute the subnet mask automatically based on the IP address that you entered. You don’t need to change the subnet mask computed by the ExpWave...
ExpWave 240B Secure Outdoor Ethernet Radio Link 5-4 Wireless Setup Figure 5-3 Menu 3 - LAN DHCP Setup From menu 3, select the submenu option TCP/IP and DHCP Setup and press [ENTER]. The screen now displays Menu 3.2 — TCP/IP and DHCP Ethernet Setup , as shown next. Figure 5-4 Menu 3.2 - LAN DHCP Ethe...
ExpWave 240B Secure Outdoor Ethernet Radio Link Wireless Setup 6-1 Chapter 6 Wireless Setup This chapter describes how to configure the Wireless operation using Menu 5 — Wireless Setup . From the main menu, enter 5 to open Menu 5 –Wireless Setup . The ExpWave AP forces the ExpWave AC into an unautho...
ExpWave 240B Secure Outdoor Ethernet Radio Link Network Setup 7-1 Chapter 7 Network Setup This chapter describes how to configure the Network Setup using Menu 6 — Network Setup . 7.1 Introduction From the main menu, enter 6 to open Menu 6 – Network Setup . Figure 7-1 Menu 6 - Router Mode Network Set...
ExpWave 240B Secure Outdoor Ethernet Radio Link 7-2 Network Setup Table 7-2 VPN security level VPN Level Authentication Encryption None None None Low MD5 None Medium MD5 DES High MD5 3DES 7.2 SMT 6.1 Menu in Router Mode Figure 7-2 AC LAN DHCP Setup Table 7-3 AC LAN DHCP Setup Menu Fields FIELD DESCR...
ExpWave 240B Secure Outdoor Ethernet Radio Link Static Route Setup 8-1 Chapter 8 Static Route Setup This chapter shows you how to configure static routes with your ExpWave . 8.1 Introduction Static routes tell the ExpWave routing information that it cannot learn automatically through other means. Th...
ExpWave 240B Secure Outdoor Ethernet Radio Link 8-2 Static Route Setup Now, enter the index number of one of the static routes you want to configure. Figure 8-3 Menu 12. 1 — Edit IP Static Route The following table describes the IP Static Route Menu fields. Table 8-1 IP Static Route Menu Fields FIEL...
ExpWave 240B Secure Outdoor Ethernet Radio Link Filter Setup 9-1 Chapter 9 Filter Setup Configuration This chapter shows you how to create and apply filters. 9.1 About Filtering Your ExpWave uses filters to decide whether to allow passage of a data packet and/or to make a call. There are two types o...
ExpWave 240B Secure Outdoor Ethernet Radio Link 9-2 Filter Setup 9.2 Configuring a Filter Set To configure a filter sets, follow the procedure below: Step 1. Select option 21. Filter Set Configuration from the Main Menu to open Menu 21 . Figure 9-2 Menu 21 - Filter Set Configuration Step 2. Select t...
ExpWave 240B Secure Outdoor Ethernet Radio Link Filter Setup 9-3 [N] means there are no more rules to check. m Refers to Action Matched. [F] means to forward the packet. [D] means to drop the packet. [N] means check the next rule. n Refers to Action Not Matched [F] means to forward the packet. [D] m...
ExpWave 240B Secure Outdoor Ethernet Radio Link 9-4 Filter Setup Figure 9-4 Menu 21.1.1 - TCP/IP Filter Rule The following table describes how to configure your TCP/IP filter rule. Table 9-4 TCP/IP Filter Rule Menu Fields Field Description Option Active This field activates/deactivates the filter ru...
ExpWave 240B Secure Outdoor Ethernet Radio Link 9-6 Filter Setup Figure 9-5 Executing an IP Filter 9.3.3 Generic Filter Rule This section shows you how to configure a generic filter rule. The purpose of generic rules is to allow you to filter non-IP packets. For IP, it is generally easier to use the...
ExpWave 240B Secure Outdoor Ethernet Radio Link Filter Setup 9-7 will be logged. Both – All packets will be logged. Matched Action Not Matched Both Action Matched Select the action for a matching packet. Check Next Rule Forward Drop Action Not Matched Select the action for a packet not matching the ...
ExpWave 240B Secure Outdoor Ethernet Radio Link SNMP Configuration 10-1 Chapter 10 SNMP Configuration This chapter explains SNMP configuration menu 22. SNMP is only available if TCP/IP is configured. 10.1 About SNMP Simple Network Management Protocol is a protocol used for exchanging management info...
ExpWave 240B Secure Outdoor Ethernet Radio Link 10-2 SNMP Configuration • Set - Allows the manager to set values for object variables within an agent. • Trap - Used by the agent to inform the manager of some events. 10.2 Supported MIBs The ExpWave supports MIB II that is defined in RFC-1213 and RFC-...
ExpWave 240B Secure Outdoor Ethernet Radio Link System Maintenance 11-1 Chapter 11 System Maintenance This chapter covers SMT menus 24.1 to 24.4. This chapter covers the diagnostic tools that help you to maintain your ExpWave. These tools include updates on system status, port status and log and tra...
ExpWave 240B Secure Outdoor Ethernet Radio Link 11-2 System Maintenance The following table describes the fields present in Menu 24.1 - System Maintenance - Status . These fields are READ-ONLY and are meant to be used for diagnostic purposes. The upper right corner of the screen shows the time and d...
ExpWave 240B Secure Outdoor Ethernet Radio Link System Maintenance 11-3 Figure 11-4 Menu 24.2.1 — System Maintenance — Information Table 11-2 Fields in System Maintenance — Information FIELD DESCRIPTION Name This is the ExpWave's system name + domain name assigned in menu 1. For example, System Name...
ExpWave 240B Secure Outdoor Ethernet Radio Link 11-4 System Maintenance 11.3 Log and Trace There are two logging facilities in the ExpWave. The first is the error logs and trace records that are stored locally. The second is the UNIX syslog facility for message logging. 11.3.1 Viewing Error Log The ...
ExpWave 240B Secure Outdoor Ethernet Radio Link System Maintenance 11-5 You need to configure the UNIX syslog parameters described in the following table to activate syslog then choose what you want to log. Table 11-3 System Maintenance Menu Syslog Parameters PARAMETER DESCRIPTION UNIX Syslog: Activ...
ExpWave 240B Secure Outdoor Ethernet Radio Link Firmware & Configuration File Maintenance 12-1 Chapter 12 Firmware and Configuration File Maintenance This chapter tells you how to back up and restore your configuration file as well as upload new firmware and a new configuration file. 12.1 Filena...
ExpWave 240B Secure Outdoor Ethernet Radio Link 12-2 Firmware & Configuration File Maintenance Please note that terms “download” and “upload” are relative to the computer. Download means to transfer from the ExpWave to the computer, while upload means from your computer to the ExpWave. 12.2.1 Ba...
ExpWave 240B Secure Outdoor Ethernet Radio Link 12-4 Firmware & Configuration File Maintenance computer. Local File Enter the path and name of the firmware file (*.bin extension) or configuration file (*.rom extension) on your computer. Remote File This is the filename on the ExpWave. The filena...
ExpWave 240B Secure Outdoor Ethernet Radio Link Firmware & Configuration File Maintenance 12-5 12.3 Restore Configuration This section shows you how to restore a previously saved configuration. Note that this function erases the current configuration before restoring a previous back up configura...
ExpWave 240B Secure Outdoor Ethernet Radio Link 12-6 Firmware & Configuration File Maintenance 12.3.3 Restore Via Console Port Restore configuration via console port by following the HyperTerminal procedure shown next. Procedures using other serial communications programs should be similar. Step...
ExpWave 240B Secure Outdoor Ethernet Radio Link Firmware & Configuration File Maintenance 12-7 When you telnet into the ExpWave, you will see the following screens for uploading firmware and the configuration file using FTP. Figure 12-13 Telnet Into Menu 24.7.1 — Upload System Firmware 12.4.2 Co...
ExpWave 240B Secure Outdoor Ethernet Radio Link 12-8 Firmware & Configuration File Maintenance Step 7. Enter “quit” to exit the ftp prompt. 12.4.4 FTP Session Example of Firmware File Upload Figure 12-15 FTP Session Example of Firmware File Upload More commands (found in GUI-based FTP clients) a...
ExpWave 240B Secure Outdoor Ethernet Radio Link Firmware & Configuration File Maintenance 12-9 where “i” specifies binary image transfer mode (use this mode when transferring binary files), “host” is the ExpWave’s IP address, “put” transfers the file source on the computer (firmware.bin – name o...
ExpWave 240B Secure Outdoor Ethernet Radio Link 12-10 Firmware & Configuration File Maintenance After the firmware upload process has completed, the ExpWave will automatically restart. 12.4.10 Uploading Configuration File Via Console Port Step 1. Select 2 from Menu 24.7 – System Maintenance – Up...
ExpWave 240B Secure Outdoor Ethernet Radio Link Firmware & Configuration File Maintenance 13-1 Chapter 13 System Maintenance & Information This chapter leads you through SMT menus 24.8 to 24.10. 13.1 Command Interpreter Mode The Command Interpreter (CI) is a part of the main router firmware....
ExpWave 240B Secure Outdoor Ethernet Radio Link 13-2 Firmware & Configuration File Maintenance Figure 13-3 Menu 24 — System Maintenance Enter 10 to go to Menu 24.10 - System Maintenance - Time and Date Setting to update the time and date settings of your ExpWave as shown in the following screen....
ExpWave 240B Secure Outdoor Ethernet Radio Link Remote Management 14-1 Chapter 14 Remote Management This chapter covers remote management found in SMT menu 24.11. 14.1 Telnet The only way to configure the ExpWave for remote management is through an SMT session using the console port. Once your ExpWa...
ExpWave 240B Secure Outdoor Ethernet Radio Link IP Policy Routing 15-1 Chapter 15 IP Routing Policy Setup This chapter covers setting and applying policies used for IP routing. 15.1 Introduction Traditionally, routing is based on the destination address only and the ExpWave takes the shortest path t...
ExpWave 240B Secure Outdoor Ethernet Radio Link 15-2 IP Policy Routing Menu 25 shows all the policies defined. Figure 15-2 IP Routing Policy Setup To setup a routing policy, perform the following procedures: Step 1. Type 25 in the main menu to open Menu 25 – IP Routing Policy Setup. Step 2. Type the...
ExpWave 240B Secure Outdoor Ethernet Radio Link IP Policy Routing 15-3 ABBREVIATION MEANING P IP layer 4 protocol number (TCP=6, UDP=17…) T Type of service of incoming packet PR Precedence of incoming packet Action GW Gateway IP address T Outgoing Type of service P Outgoing Precedence Service NM Nor...
ExpWave 240B Secure Outdoor Ethernet Radio Link 15-4 IP Policy Routing FIELD DESCRIPTION Len Comp Press [SPACE BAR] and then [ENTER] to choose from Equal , Not Equal , Less , Greater , Less or Equal or Greater or Equal . Source addr start / end Source IP address range from start to end. port start /...
ExpWave 240B Secure Outdoor Ethernet Radio Link IP Policy Routing 15-5 15.6 IP Policy Routing Example If a network has both Internet and remote node connections, you can route Web packets to the Internet using one policy and route FTP packets to a remote network using another policy. See the next fi...
ExpWave 240B Secure Outdoor Ethernet Radio Link 15-6 IP Policy Routing Step 5. Create a rule in menu 25.1.1 for this set to route packets from any host (IP=0.0.0.0 means any host) with protocol TCP and port FTP access through another gateway (192.168.1.100). Figure 15-9 IP Routing Policy Step 6. Che...
Zyxel Manuals
-
Zyxel G-360
Manual
-
Zyxel 35
Manual
-
Zyxel PLA4225
Manual
-
Zyxel G-170S
Manual
-
Zyxel 128MH
Manual
-
Zyxel Vantage Access
Manual
-
Zyxel PLA-4xx
Manual
- Zyxel G-220 v3 Manual
-
Zyxel DMA-1000 Series
Manual
-
Zyxel AG-100
Manual
- Zyxel 2002 Series Manual
- Zyxel P-334U Manual
-
Zyxel P-872H
Manual
-
Zyxel P-660RU Series
Manual
- Zyxel 5 Manual
-
Zyxel NSA310
Manual
-
Zyxel PLA-400 v2
Manual
-
Zyxel Wireless PCI Adapter
Manual
-
Zyxel NWD2105
Manual
-
Zyxel plx111
Manual