Page 2 - shown on the rating plate is not permitted.; QUALIFIED SERVICE TECHNICIAN.
Table of Contents General Information and Technical Data Instructions to Installer ………………………………………………………………………….……….................………… 1 Safety and General Warnings ………………………………………………………………….…………………...………... 2 Technical Data ……………………………………………………………………………………….…………...……………. 3 Installation Wall Insta...
Page 3 - Safety Rules and General Warnings; DO NOT OPERATE THIS FURNACE WITHOUT FRONT PANEL INSTALLED; Safety Information for Users of LP Gas; That’s your signal to go into immediate action!; Close all gas tank or cylinder supply valves.
Safety Rules and General Warnings DO NOT OPERATE THIS FURNACE WITHOUT FRONT PANEL INSTALLED • Due to high temperatures, the furnace should be located out of traffic and away from furniture and draperies. • Children and adults should be alerted to the hazards of high surface temperatures and should s...
Page 4 - Some Points to Remember; Learn to recognize the odor of LP Gas.; Technical Data
Some Points to Remember • Learn to recognize the odor of LP Gas. Your local LP Gas Dealer can give you a ”Scratch and Sniff” pamphlet. Use it to find out what the propane odor smells like. If you suspect that your LP Gas has a weak or abnormal odor, call your LP Gas Dealer. • If you are not qualifie...
Page 5 - Installation; Installation should be done by a QUALIFIED SERVICE TECHNICIAN.; Wall Installation
Installation Installation should be done by a QUALIFIED SERVICE TECHNICIAN. The furnace must be located on an outside wall. Wall Installation Minimum clearances from combustible materrials: WARNING: For the installation of this furnace, the following items must be used as a vent air intake system: •...
Page 7 - Insert the smallest tube (diameter 2
5. Place the insulating sheet on the support bracket and attach the bracket with insulation to the wall by tightening the five screws with washer. (Figure 3) Be sure the bracket is horizontal. 6. Remove the casing from the furnace body, unscrewing the two mounting screws. (Figure 3) 7. Mount the lar...
Page 8 - Gas Supply
8. Position the furnace on the wall inserting the inlet/outlet flue in the hole previously drilled. Make sure that the edges of the support bracket perfectly match the existing holes in the back on the unit (Figure 5) 9. Attach the furnace to the support bracket with the two screws provided. During ...
Page 9 - Attention; it will result in a hazardous condition.; First Firing the Furnace
3. The furnace must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). Attention : If one of the above procedures results in pressures in ...
Page 10 - Operating Instructions; FOR YOUR SAFETY READ BEFORE OPERATING; WHAT TO DO IF YOU SMELL; OPERATING INS
Operating Instructions Before operating the furnace, read carefully all warnings and safety information in this manual. FOR YOUR SAFETY READ BEFORE OPERATING A. This appliance has a pilot which must be lighted by means of the piezo igniter installed on the unit. Do not try to light the pilot by hand...
Page 11 - Servicing; external casing must be reinstalled properly.; Checking and Adjusting the Gas Manifold Pressure; Do not; Lubrication of Moving Parts
Servicing All servicing activities must be carried out by a qualified service technicial or a service agency. The home owner may not service the furnace. The home owner must read this section to be informed of the periodic maintenance and checks the required. All servicing (except on vent system) mu...
Page 12 - Replacement Parts
Replacement Parts Gas Valve Part Number: JVLV023 (Natural Gas) Part Number: JVLV024 (LPG) Pilot Sparking Candle and Nozzle Part Number: J12306065 (Sparking Candle) Part Number: JGLL064 (Nozzle – Natural Gas) Part Number: J12160880 (Nozzle - LPG) Piezo Electric Button Part Number: JPZO000 Thermocoupl...