23552-5-0608 Page 2 Section Page TABLE OF CONTENTS Important Safety Information ............................................................................................................................ 3Safety Information for Users of LP Gas ..........................................................
Page 3 - IMPORTANT SAFETY INFORMATION
23552-5-0608 Page 3 DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. • Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies. • The...
Page 4 - SAFETY INFORMATION FOR USERS OF LP GAS
23552-5-0608 Page 4 SOME POINTS TO REMEMBER NO ODOR DETECTED - ODOR FADE LP-GAS WARNING ODOR If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas. That’s your signal to go into immediate action! SAFETY INFORMATION FOR USERS OF LP GAS Propane (LP-Gas) is...
Page 5 - REQUIREMENTS FOR MASSACHUSETTS; “GAS VENT DIRECTLY BELOW.
23552-5-0608 Page 5 REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust ve...
Page 6 - INTRODUCTION
23552-5-0608 Page 6 Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty card supplied with the fireplace. 3. Installer should show owner how to start and operate the fireplace. This direct vent gas fi...
Page 7 - SPECIFICATIONS
23552-5-0608 Page 7 Remote Control Options & Accessories Description FRBC Millivolt Battery Remote ON/OFF FRBTC Millivolt Battery Remote Thermostat FREC Direct Ignition/Millivolt 120V ON/OFF Remote TMW Millivolt Wireless Wall Thermostat TRW Millivolt Reed Switch Wall Thermostat FWS-1 Direct Igni...
Page 8 - FIREPLACE DIMENSIONS
23552-5-0608 Page 8 Figure 1 Dim DVD32 DVD36 DVD42 DVD48 A 34" 864 mm 37" 940 mm 43" 1092 mm 49" 1245 mm B 31" 787 mm 34" 864 mm 40" 1016 mm 46" 1168 mm C 23 1/16" 585 mm 23 1/16" 585 mm 25 1/16" 636 mm 25 1/16" 636 mm D 35 5/8" 905 mm 35 5/8" ...
Page 9 - CLEARANCES
23552-5-0608 Page 9 Mantel Chart (Figure 3) Figure 3 Clearances (Figure 4) Clearance from top front edge of fireplace to ceiling is 36" Clearance from side of fireplace to adjacent sidewall is 6". Figure 4 15” (381mm) TOP EDGE OF FIREPLACE 12” (305mm) 10” (254mm) MANTEL COMBUSTIBLE TRIM AND MA...
Page 10 - LOCATING FIREPLACE
23552-5-0608 Page 10 Figure 5 Note: Island (C) and Room Divider (D) installation is possible as long as the horizontal portion of the vent system (H) does not exceed 20 feet with a minimum vertical run of 8 feet. See details in Venting Section.When you install your Direct Vent Fireplace in (D) Room ...
Page 11 - GAS SUPPLY
23552-5-0608 Page 11 Figure 6 The gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation code. Installing a New Main Gas Cock Each appliance should have its own manual gas cock.A man...
Page 12 - REAR VENT CONVERSION; SPECIAL VENT SYSTEMS; Empire Horizontal Round Termination Kit DVVK-4RE, refer to Page 30.
23552-5-0608 Page 12 REAR VENT CONVERSION Converting flue take-off to rear venting When switching out the flue and inlet vent collars to run horizontally off the rear vent, the following steps must be taken.1. Remove the inlet vent collar (8 screws) and flue collar (4 screws) from the top of the firepla...
Page 13 - INSTALLATION
23552-5-0608 Page 13 Framing and Finishing 1. Choose unit location. 2. Frame in fireplace with a header across the top. It is important to allow for finished face when setting the depth of the frame. 3. Attach fireplace to frame using adjustable frame. Preset depth to suit facing material (adjustable t...
Page 18 - VENTING FIREPLACE - TOP
23552-5-0608 Page 18 To Use the Vent Graph (Figure 20) 1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the Sidewall Vent Graph, locate the point it intersects with the slanted graph line. 2. From the point of this intersection, draw a vertical line to the b...
Page 19 - Firestop at
23552-5-0608 Page 19 Figure 22 Examples of possible venting systems using two (2) 90° elbows. V is listed as minimum vertical dimensions and H1 + H2 is listed as total of maximum horizontal dimensions. The maximum vertical and horizontal distances for two (2) 90° elbows as shown in Figure 23 is 20 f...
Page 21 - EXAMPLES - TOP VENT RUN
23552-5-0608 Page 21 Figure 27 Figure 28 Figure 29 24” 24” MINIMUM CLEARANCE TO COMBUSTIBLES EXAMPLES - TOP VENT RUN
Page 22 - VENTING FIREPLACE - REAR
23552-5-0608 Page 22 To Use the Vent Graph (Figure 30) 1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the Sidewall Vent Graph, locate the point it intersects with the slanted graph line. 2. From the point of this intersection, draw a vertical line to the b...
Page 23 - EXAMPLES - REAR VENT RUN
23552-5-0608 Page 23 Figure 31 Figure 32 Figure 33 Figure 34 Model Maximum Pipe Length H1 DVD32 24" DVD36 24" DVD42 18" DVD48 N/A Model Maximum Pipe Length H1 DVD32 24" DVD36 24" DVD42 24" DVD48 6" EXAMPLES - REAR VENT RUN
Page 24 - TERMINATION CLEARANCES
23552-5-0608 Page 24 Termination clearance for buildings with combustible and noncombustible exteriors. Vertical Sidewall Installations Important! Minimum clearance between vent pipes and combustible materials is three (3") (76 mm) on top, and (1") (25 mm) on bottom and sides. Important! Whe...
Page 25 - VENT CLEARANCES
23552-5-0608 Page 25 Figure 36 A = *Clearance above grade, veranda, porch, deck or balcony [*12 inches (305 mm) minimum] B = clearance to window or door that may be opened [*12 inches (305 mm) minimum for appliances < 100,000 BTU/Hr (30 kW) C = clearance to permanently closed window [minimum 12 i...
Page 26 - VENT SYSTEM IDENTIFICATION
23552-5-0608 Page 26 I nstalling Vent Components (Figure 37) Begin the vent system installation by installing the first Simpson Duravent component, 90° elbow to the starting collars or straight pipe on the top of the appliance, then the straight pipe length and then horizontal or vertical termination...
Page 27 - FRAMING AND FINISHING
23552-5-0608 Page 27 FRAMING AND FINISHING Installing Support Brackets (Figure 38) A horizontal pipe support MUST BE used for each 3 feet of horizontal run. The pipe supports should be placed around the pipe and nailed in place to framing members. There MUST BE a 3 inch clearance to combustibles abo...
Page 29 - HORIZONTAL TERMINATION
23552-5-0608 Page 29 NOTE: Termination cap should pass through the wall firestop from the exterior of the building. Adjust the termination cap to its final exterior position on the building. WARNING: Termination cap must be positioned so that arrow is pointing up. Attach the termination cap with the f...
Page 30 - DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS
23552-5-0608 Page 30 X X = 13/3/4” MAX TOTAL WALL THICKNESS (SUBTRACT 3” IF USING THE DV822 VINYL SIDING KIT) ½” AIRSPACECLEARANCE 11” 9” NOTE: SPACING FLANGE INSTALLED TO TOPSIDE INTERIOR WALL EXTENSION THIMBLE DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS CAUTION: Sharp edges, use protective gloves ...
Page 33 - DVVK-4F FLEX VENT INSTRUCTIONS
23552-5-0608 Page 33 the vent end connectors. 8. Attach the Termination Cap to the outside of the house. 9. Prior to making the vent connections, apply high temperature sealant (1000 degree F min.) to the vent connections before securing with the band clamps provided. Note: the flue pipe end without...
Page 34 - VERTICAL TERMINATION
23552-5-0608 Page 34 Locate and mark the center point of the vent pipe using a nail on the underside of the roof. Drive the nail through the center point. Mark the outline of the roof hole around this center point. NOTE: Size of the roof hole dimensions depend on the pitch of the roof. There must be...
Page 38 - OPERATING INSTRUCTIONS
23552-5-0608 Page 38 The OWNER should carefully read and follow these operating instructions at all times. Lower the door assembly to view the gas controls for the fireplace. Initial Lighting Upon completing the gas line or turning the gas valve on after it has been in the “OFF” position, a small amo...
Page 40 - STANDING PILOT WIRING DIAGRAM
23552-5-0608 Page 40 Figure 60 (OPTIONAL) THERMOSTAT (OPTIONAL) WALL SWITCH STANDING PILOT WIRING DIAGRAM
Page 41 - STANDING PILOT LIGHTING INSTRUCTIONS; FOR YOUR SAFETY READ BEFORE LIGHTING
23552-5-0608 Page 41 1. Stop! Read the safety information above. 2. Set REMOTE/OFF/ON switch to OFF. 3. Turn off all electric power to the appliance (if applicable). 4. Lower bottom louver assembly. 5. Push in gas control knob slightly and turn clockwise to "OFF." Note: Knob cannot be turned...
Page 42 - STANDING PILOT TROUBLESHOOTING
23552-5-0608 Page 42 With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and t...
Page 43 - DIRECT IGNITION WIRING DIAGRAM; OPTIONAL REMOTE CONTROL
23552-5-0608 Page 43 DIRECT IGNITION WIRING DIAGRAM LED LIGHT LED LUMIÈRE BLACK NOIR GREEN VERT WHITE BLANC RED ROUGE BLACK NOIR GAS VALVE VALVE DE GAZ (OPTIONAL) WALL SWITCH INTERRUPTEUR MURAL (FACULTATIVE) 120 VAC LINE 120 VAC RTN JUNCTION BOX JONCTION BOÎTE SPARK IGNITOR ÉTINCELLE ALLUMER (OPTION...
Page 44 - DIRECT IGNITION LIGHTING INSTRUCTIONS
23552-5-0608 Page 44 A. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance • Do not touch any electrical switch • Do not use a...
Page 45 - INITIAL START UP GAS LINE PURGE; PURGE PROCEDURE; DIRECT IGNITION TROUBLESHOOTING
23552-5-0608 Page 45 1. Remove glass door and place away from the fireplace. 2. Turn on gas shut off valve. Follow ignition procedure. 3. If burner does not light after spark sequence has ended, use an insulated jumper wire (see page 43) between terminal locations 12 and 13 for fast reset function. 4...
Page 46 - DIRECT IGNITION PROPANE/LP GAS CONVERSION
23552-5-0608 Page 46 The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the CSA B149.2 installation code (Canada) and with the requirements of the National Fuel Gas Code Z223.1/NFPA 54 (...
Page 48 - MAINTENANCE AND SERVICE
23552-5-0608 Page 48 PLEASE NOTE It is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. It is not unusual for your gas fireplace to give off so...
Page 49 - PARTS LIST
23552-5-0608 Page 49 USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. INDEX NO. PART NUMBER DESCRIPTION DVD32 DVD36 DVD42 DVD48 1 R-7654 R-7654 R-7654 R-7654 FLUE INSULATION 2 17425 17425 17425 17425 FLUE INSULATION RETAINER 3 R-7566 R-7566 R-7566 R-7566...
Page 50 - PARTS VIEW
23552-5-0608 Page 50 1 2 3 4 5 6 7 14 15 15 30 33 34 35 31 44 45 41b 36 32 39 40b 48 50 37b 38 51 49 39 32 43 42 30 33 34 35 41a 31 36 37a 38 52 40a 52 22 23 24 26 27 22 25 26 29 28 14 13 13 13 13 8 9 10 11 12 16 19 20 21 17 18 DIRECT IGNITION BURNER ASSEMBL Y MILLIVOL T BURNER ASSEMBL Y 5 PIECE LOG...
Page 51 - FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION
23552-5-0608 Page 51 Attention : Install blower assembly before connecting gas inlet supply line Note : Junction box on right side of fireplace must be pre-wired at time of fireplace installation for use with blower assembly. It is recommended that an ON/OFF wall switch be installed that will activate...
Page 53 - 20V DIRECT IGNITION VALVE MODELS
23552-5-0608 Page 53 CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRI- CALL...
Page 54 - ACCESSORIES
23552-5-0608 Page 54 ACCESSORIES Accessory Description Model Number Fan Kit This fan kit is designed to provide forced air flow. Variable Speed FBB4 Simulated Brick Panels The simulated brick panels are designed to enhance the ap- pearance of your fireplace, imitating the look of authentic masonry. HE...
Page 55 - DECORATIVE ACCESSORIES
23552-5-0608 Page 55 DECORATIVE ACCESSORIES Decorative Louver Mission Decorative Louver Arch Decorative Louver Leaf Decorative Frame Rectangle (with hinges) Decorative Door Leaf Rectangle Decorative Door Mission Rectangle Decorative Door Plain Rectangle Decorative Frame Arch (with hinges) Decorative...
Page 57 - SERVICE NOTES