Page 2 - Section Page; TABLE OF CONTENTS
23340-4-0608 Page 2 Important Safety Information ......................................................................................................................................... 3 Safety Information for Users of LP Gas ...........................................................................
Page 3 - IMPORTANT SAFETY INFORMATION
23340-4-0608 Page 3 DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. • If this appliance is installed directly on carpeting, tile or other combustible material other than wood flooring th...
Page 4 - SAFETY INFORMATION FOR USERS OF LP GAS
23340-4-0608 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detec...
Page 5 - REQUIREMENTS FOR MASSACHUSETTS
23340-4-0608 Page 5 REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust ve...
Page 6 - INTRODUCTION
23340-4-0608 Page 6 Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty card supplied with the fireplace. 3. Installer should show owner how to start and operate the fireplace. This direct vent gas fi...
Page 7 - SPECIFICATIONS
23340-4-0608 Page 7 Figure 1 DVP36 A 39" 99.1 cm B 36" 91.4 cm C 25 1/16" 63.7 cm D 37 5/8" 96 cm E 34 3/4" 88 cm F 19 7/8" 50.5 cm G 26 1/2" 66 cm H 7 1/8" 18.1 cm I 27" 68.6 cm J 13 1/2" 34.6 cm K 12 3/4" 32.4cm RIGHT SIDE VIEW J H K Remote Control Optio...
Page 8 - CLEARANCES
23340-4-0608 Page 8 15” (381mm) TOP EDGE OF FIREPLACE 12” (305mm) 10” (254mm) MANTEL COMBUSTIBLE TRIM AND MANTELS ALLOWED IN SHADED AREA 4” 5” 6” 7” 8” 9” 11” 13 3/4” 3/4” 1 ½” 2 1/4” 3” 3 3/4” 4 ½” 6” 8” 3” Mantel Chart (Figure 3) Figure 3 Clearances (Figure 4) Clearance from top of fireplace to cei...
Page 9 - GAS SUPPLY
23340-4-0608 Page 9 Figure 6 T he gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation code. Installing a New Main Gas Cock Each appliance should have its own manual gas cock.A man...
Page 10 - REAR VENT CONVERSION; SPECIAL VENT SYSTEMS; Empire Horizontal Round Termination Kit DVVK-4RE, refer to page 34.
23340-4-0608 Page 10 REAR VENT CONVERSION Note : Discard insulation & retainer when using vertical venting off VERTICAL VENTING HORIZONTAL VENTING FLUE INSULATION INSULATION RETAINER INLET VENT COLLAR INLET VENT COLLAR FLUE OUTLET COLLAR FLUE COVER PLATE (See note above) INLET VENT COVER PLATE F...
Page 11 - INSTALLATION
23340-4-0608 Page 11 Framing and Finishing 1. Choose unit location. 2. Frame in fireplace with a header across the top. It is important to allow for finished face when setting the depth of the frame. 3. Attach fireplace to frame using adjustable frame. Preset depth to suit facing material (adjustable t...
Page 18 - Installation Instructions; starting the installation.; DVVK-4FV DIRECT VENT TERMINATION KIT
23340-4-0608 Page 18 Installation Instructions This termination kit can only be used with Empire Comfort Systems direct vent fireplaces listed for use with DVVK-4FV Vertical Flex Vent Kit. Please review the instructions packaged with your fireplace and verify the fireplace model number. Check that this...
Page 20 - Step-By-Step Installation For Flex DV Kit
23340-4-0608 Page 20 1. Unpack vent components and check all items for shipping damage. 2. For this venting system to operate as designed it is depen- dent on the use of all parts and procedures detailed in these instructions. Failure to follow these instructions may poten- tially affect the perform...
Page 23 - Venting Support
23340-4-0608 Page 23 Figure 33 Storm Clearance to Combustibles Collar Exterior Roof Roof Flashing Roof Jack Adjustable Assembly 4' Long Rigid Pipe Direct VentFireplace Required From Vent Pipe Firestop/Thimble Ceiling Straps (As Req'd.) Venting Support With Gasket & Clamps 7" Dia. Adapter Col...
Page 24 - Vertical Flex Termination Kit
23340-4-0608 Page 24 Vertical Flex Termination Kit Item Number Item Description Repair Part No. Quantity Supplied 1 4”/7” Vertical Termination Cap MF100038 1 2 Roof Support Kit MF100503 1 3 2 Ply Alum Flex 4” Diameter by 6 ft. MF04ALA2F006 1 4 2 Ply Alum Flex 7” Diameter by 6 ft. MF07ALA2F006 1 5 4”...
Page 25 - EXAMPLES - TOP VENT RUN
23340-4-0608 Page 25 Figure 34 Figure 35 Figure 36 24” 24” MINIMUM CLEARANCE TO COMBUSTIBLES EXAMPLES - TOP VENT RUN LP and Nat models LP and Nat models LP and Nat models
Page 27 - EXAMPLES - REAR VENT RUN
23340-4-0608 Page 27 Figure 38 Figure 39 Figure 40 Figure 41 Model Maximum Pipe Length H1 DVP36 24" Model Maximum Pipe Length H1 DVP36 24" EXAMPLES - REAR VENT RUN Nat models only Nat models only Nat models only Nat models only
Page 28 - TERMINATION CLEARANCES
23340-4-0608 Page 28 Termination clearance for buildings with combustible and noncombustible exteriors. Vertical Sidewall Installations Important! Minimum clearance between vent pipes and combustible materials is three (3") (76mm) on top, and (1") (25mm) on bottom and sides. Important! When ...
Page 29 - VENT CLEARANCES
23340-4-0608 Page 29 Figure 43 A = *Clearance above grade, veranda, porch, deck or balcony [*12 inches (30cm) minimum] B = clearance to window or door that may be opened [*12 inches (30cm) minimum for appliances < 100,000 Btuh (30kW) C = clearance to permanently closed window [minimum 12 inches (...
Page 30 - VENT SYSTEM IDENTIFICATION
23340-4-0608 Page 30 Installing Vent Components (Figure 44) Begin the vent system installation by installing the first Simpson Duravent component, 90° elbow to the starting collars or straight pipe on the top of the appliance, then the straight pipe length and then horizontal or vertical termination ...
Page 31 - FRAMING AND FINISHING
23340-4-0608 Page 31 Installing Support Brackets (Figure 45) A horizontal pipe support MUST BE used for each 3 feet of horizontal run. The pipe supports should be placed around the pipe and nailed in place to framing members. There MUST BE a 3 inch clearance to combustibles above 6 5/8 inch diameter...
Page 33 - HORIZONTAL TERMINATION
23340-4-0608 Page 33 NOTE: Termination cap should pass through the wall firestop from the exterior of the building. Adjust the termination cap to its final exterior position on the building. WARNING: Termination cap must be positioned so that arrow is pointing up. Attach the termination cap with the f...
Page 34 - DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS
23340-4-0608 Page 34 C A U T I O N : S h a r p e d g e s , u s e p ro t e c t i v e g l o v e s w h e n installing. Tools Needed for Installation: Sheet metal snips 5/16” nut driver Phillips head screwdriver - #2 High temperature sealant or furnace cement rated for continuous use at 1,000 o F minimu...
Page 37 - DVVK-4F FLEX VENT INSTRUCTIONS
23340-4-0608 Page 37 8 (203 mm) 8 (203 mm) 8 (203 mm) 4 FLEX VENT PIPE SPACER SPRING FIGURE B ”” ” ” ” FLEX OUTER VENT FLEX FLUE PIPE SPACER SPRINGS FIGURE A Top of Vent Combustibles NOT allowed in shaded area 1" 1" 3" (25 mm) 7 ” Diameter intake vent 4 ” Diameter flue (25 mm) (76 mm) FI...
Page 38 - VERTICAL TERMINATION
23340-4-0608 Page 38 Locate and mark the center point of the venting pipe. Using a nail on the underside of the roof and drive this nail through this center point. Make the outline of the roof hole around this center point. NOTE: Size of the roof hole dimensions depend on the pitch of the roof. Ther...
Page 41 - OPERATING INSTRUCTIONS
23340-4-0608 Page 41 Initial Lighting Upon completing the gas line or turning the gas valve on after it has been in the “OFF” position, a small amount of air will be in the lines. When first lighting the fireplace, it will take a few minutes for the lines to purge themselves of this air. Once the purg...
Page 43 - STANDING PILOT WIRING DIAGRAM
23340-4-0608 Page 43 Figure 66 (OPTIONAL) THERMOSTAT (OPTIONAL) WALL SWITCH STANDING PILOT WIRING DIAGRAM
Page 44 - STANDING PILOT LIGHTING INSTRUCTIONS
23340-4-0608 Page 44 1. Stop! Read the safety information above. 2. Set REMOTE/OFF/ON switch to OFF. 3. Turn off all electric power to the appliance (if applicable). 4. Lower bottom louver assembly. 5. Push in gas control knob slightly and turn clockwise to "OFF." Note: Knob cannot be turned...
Page 45 - STANDING PILOT TROUBLESHOOTING
23340-4-0608 Page 45 With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and t...
Page 46 - INTERMITTENT PILOT OPERATING INSTRUCTIONS
23340-4-0608 Page 46 1. To wire Junction Box Receptacle, remove the tab on the side of the receptacle (hot side) to split receptacle. This will be required to separate blower and valve circuits. 2. Power for switched and live sides of Duplex Receptacle must come from the same power source. (One circ...
Page 47 - FOR YOUR SAFETY READ BEFORE LIGHTING; causing property damage, personal injury or loss of life.; LIGHTING INSTRUCTIONS; INTERMITTENT PILOT LIGHTING INSTRUCTIONS
23340-4-0608 Page 47 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which automatically lights the pilot. Do n...
Page 48 - INTERMITTENT PILOT TROUBLESHOOTING
23340-4-0608 Page 48 GENERAL: All fireplaces have been fire-tested to check for proper operation. This includes, main burner flame, pilot flame, fan operation, fan control, limit control and automatic valve operation. If the fireplace fails to function on initial installation, it is advisable to re-check...
Page 49 - S8600H NORMAL OPERATING SEQUENCE
23340-4-0608 Page 49 Spark Generator Powered First Valve (Pilot) Operator Opens Pilot burner lights. Module senses flame current. PILOT BURNER OPERATION MODULES8600H * Lockout timing is stamped on module. RESPONSEAfter 90 seconds*pilot valve closes, spark stops. OR IF FLAME CURRENT SENSED Spark gene...
Page 50 - INTERMITTENT PILOT TROUBLESHOOTING (continued)
23340-4-0608 Page 50 Important 1. The following service procedures are provided as a general guide. 2. Meter readings between gas control and ignition module must be taken within the trial for ignition period. Once the igni- tion module locks out, the system must be reset by setting the thermostat d...
Page 52 - Green LED Status Codes; Flash Code Descriptions:
23340-4-0608 Page 52 INTERMITTENT PILOT TROUBLESHOOTING (continued) Green LED Status Codes Green LED Flash Code (X + Y) a Indicates Next System Action Recommended Service Action OFF No “Call for Heat” Not applicable None Flash Fast Startup-Flame sense calibration Not applicable None Heart Beat Norma...
Page 53 - RF STANDING PILOT OPERATING INSTRUCTIONS
23340-4-0608 Page 53 Functions • Flame powered system • Flame powered flame modulation • Electronics integrated into valve to provide thermostat, flame, and fan functions with RF commands • Temperature compensated RF receiver • Main burner goes to "high" when manual switch is set on "local...
Page 54 - RF TRANSMITTER FUNCTIONS
23340-4-0608 Page 54 FIRST USE OF TRANSMITTERStatus Action Begin communication between transmitter and receiver/valve. Move LOCAL/REMOTE Switch to LOCAL position for at least two seconds; then move switch to the REMOTE position. Transmit unique code. Press Fan or Flame key within 30 seconds. Confirm ...
Page 55 - RF WIRING DIAGRAM
Page 56 - WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR; RF STANDING PILOT LIGHTING INSTRUCTIONS
23340-4-0608 Page 56 1. STOP! Read the safety information above. 2. Tu r n o f f a l l e l e c t r i c p o w e r t o t h e a p p l i a n c e ( i f applicable). 3. Lower louver front assembly. 4. Push in gas control knob slightly and turn clockwise to "OFF". NOTE: Knob cannot be turned from &...
Page 57 - MAINTENANCE AND SERVICE
23340-4-0608 Page 57 PLEASE NOTE It is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. It is not unusual for your gas fireplace to give off so...
Page 58 - PARTS VIEW
23340-4-0608 Page 58 PARTS VIEW 15* 12 12 7 8 9 10 11 12 20 19 13 12 23 22a 21 17 18 16 1 2 3 4 5 6 11 14 27 28 29 31 30 24 33 32 34 40 38 42 39a 36a 37a 41 52 39b 34 33 32 24 30 29 28 27 31 36b 44 46 37b 33 34 32 36c 37c 31 29 28 27 24 23 30 48 49 50 51 47 45 15 26 26 26 43 MILLIVOL T BURNER ASSEMB...
Page 59 - PARTS LIST
23340-4-0608 Page 59 INDEX NO. PART NUMBER DESCRIPTION DVP36 1 R-7654 FLUE INSULATION 2 17426 FLUE INSULATION RETAINER 3 R-7566 INLET VENT ADAPTOR 4 R-7573 INLET VENT GASKET 5 17155 FLUE OUTLET ASSEMBLY 6 M163 FLUE CONNECTOR GASKET 7 17142 VENT COVER PLATE 8 R-7575 VENT COVER PLATE GASKET 9 17141 FL...
Page 61 - FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION
23340-4-0608 Page 61 Attention: Install blower assembly before connecting gas inlet supply line Note: Junction box on right side of fireplace must be pre-wired at time of fireplace installation for use with blower assembly. It is recommended that an ON/OFF wall switch be installed that will activate t...
Page 63 - JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS
23340-4-0608 Page 63 CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY ...
Page 64 - DECORATIVE ACCESSORIES; ACCESSORIES
23340-4-0608 Page 64 The following accessory parts can be obtained from your Empire Comfort Systems dealer. If you need additional information beyond what your dealer can furnish, contact Empire Comfort Systems Inc., Nine Eighteen Freeburg Ave., Belleville, Illinois 62220-2623.Accessory Description ...
Page 65 - HOW TO ORDER REPAIR PARTS
23340-4-0608 Page 65 Parts can be ordered only through your service person or dealer . For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer. All parts listed in the Parts List have a Part Number. When or...
Page 66 - SERVICE NOTES