Page 2 - only; INTRODUCTION
1 If you have questions concerning theoperation of this Whistler productplease call customer service: 1-800-531-0004 Hours: Monday - Friday 8:00 am - 5:00 pm CT Please keep the receipt in a safe place. You may register your product online at www.whistlergroup.com. If the unit is returned without a d...
Page 3 - WHISTLER FEATURES; TABLE OF CONTENTS
WHISTLER FEATURES A Word About Whistler Power Inverters Whistler inverters convert low voltage, direct current (DC) to 110 volt alternating household current (AC). The AC output is called “modified sine wave”. See “Technical Operating Principles” section for more information. Depending on the model ...
Page 5 - INVERTER INFORMATION; Important Information; This is especially true for medical equipment.; IMPORTANT INFORMATION
INVERTER INFORMATION Important Information About Your New Whistler Inverter. This manual will provide you with directions for the safe and efficient operation of your Whistle Power Inverter. Read the manual carefully before using your new Whistler inverter and keep the manual on file for future refe...
Page 6 - Selecting the Optimum Power Source.
power overload. Testing appliances and equipment withstart up load ratings comparable to your inverter wattagerating will not damage it. If a piece of equipment or an appliance will not operate,first confirm that the inverter has been properly connectedto the 12 volt power source (See "Making Th...
Page 7 - BATTERY/CABLE INFORMATION; whistlergroup; BATTERY INFORMATION; To calculate the Ah of the battery, first determine its
11 BATTERY/CABLE INFORMATION • It may be advisable to operate the inverter from a bankof batteries of the same type in a "parallel" configuration.Two such batteries will generate twice the Ah of asingle battery; three batteries will generate threetimes the Ah and so on. See “Making a Connect...
Page 8 - Check Whistler’s online store for cable availability.; CABLE INFORMATION; Making the Connection.
Pro-2000W and Pro-2500W When the inverter and the battery are set up within threefeet of each other, use a minimum of #2 gauge wire to makethe connections. Within four to six feet, use a #0 gauge wire(Pro-2000W), #00 gauge for Pro-2500W. At distancesbetween six feet to ten feet, use #000 gauge wires...
Page 9 - Failure to heed
15 14 OPERATION OPERATION 7. Confirm that the equipment or appliance to beoperated is turned off. Plug the equipment orappliance into one of the AC receptacles on thefront panel of the the inverter. 8. Turn the inverter to the ON (I) position. Turn on theequipment or appliance. 9. Plug the USB power...
Page 10 - Important Information on Battery Chargers
OPERATION OPERATION 16 • Check frequently to ensure that the input and output connections are secure. Loose connectionsmay damage the inverter, the power source, or may generate excessive heat. To generate the maximum output, the Pro-3000W wattmodel (for example) should be connected to a powersupply...
Page 11 - Some Powerful Advice.
19 18 OPERATION OPERATION Some Powerful Advice. When driving with the inverter in operation, make certain thatneither the inverter nor the power cords will impede safeoperation of your vehicle. Keep the unit and all cords clearof the steering wheel, gas, brake and clutch pedals and gear shift. To ma...
Page 12 - For You Technical Types.
OPERATING PRINCIPALS 21 20 OPERATION For You Technical Types. 1. Basic Operating Principles: Whistler inverters work in two stages. During the first stage,the DC to DC converter increases the DC input voltage fromthe power source (e.g. a 12 volt battery) to 145 volts DC. Inthe second stage, the high...
Page 13 - OPERATION SUMMARY; Do not expose the inverter to moisture.; OPERATING PRINCIPALS/SUMMARY; Before attempting to use a battery charger see page 16.
OPERATION SUMMARY • In the event of automatic shut down, turn the inverterOFF (O) immediately. Do not restart the inverter until thesource of the problem has been identified and corrected. • To avoid battery drain, always disconnect the inverterwhen the vehicle is not in use for long periods. • Do n...
Page 15 - SPECIFICATION
SPECIFICATION Pro-1200W WATT INVERTER SPECIFICATIONS Maximum Continuous Power . . . . . . . . . . . . . . . . . . . .1200 WattsMaximum Surge Capability (Peak Power) . . . . . . . . . .2400 Watts * No Load Current Draw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .< 1.0AWaveform . . ....
Page 16 - • A copy of your dated store receipt or bill of sale.; WARRANTY; Consumer Warranty
WARRANTY IMPORTANT: Whistler will not assume responsibility for lossor damage incurred in shipping. Therefore, please ship yourinverter insured with return receipt requested. 2. Include the following clearly printed information:• Your name and street address (for shipping via UPS), a daytime telepho...
Page 17 - personal checks are not accepted
MEMO 31 30 WARRANTY The out of warranty service fee for the Pro Series inverters areas follows:Pro-1200W inverter is $75.00Pro-1600W inverter is $95.00Pro-2000W inverter is $125.00Pro-2500W inverter is $155.00Pro-3000W inverter is $185.00. If you require out of warranty service, please return yourin...