Page 2 - Your warranty period; only; INTRODUCTION
1 If you have questions concerning theoperation of this Whistler productplease call customer service: 1-800-531-0004 Hours: Monday - Friday 8:00 am - 5:00 pm CT Please keep the receipt in a safe place.You may register your product online atwww.whistlergroup.com. If the unit isreturned without a date...
Page 3 - WHISTLER FEATURES; A Word About Whistler Power Inverters; This switch controls the flow of power; TABLE OF CONTENTS
WHISTLER FEATURES A Word About Whistler Power Inverters Whistler inverters convert low voltage, direct current (DC)to 110 volt alternating household current (AC). The AC outputis called “modified sine wave”. See “Technical OperatingPrinciples” section for more information. Depending onthe model and ...
Page 4 - This illuminated Digital display moni-; FEATURES
FEATURES d). Wattage & VoltageWattage Indicator. This illuminated Digital display moni- tors the wattage being consumed by the inverter. When the reading rises above the rated limits, the invertermay automatically shut down. In this event, it is likely thatthe draw of the equipment or appliance ...
Page 5 - This fan will turn on; is equipped with a 15 amp circuit breaker.
FEATURES e). Standard North American 110 AC Outlets are provided. f). High Speed Cooling Fan. This fan will turn on automatically when the internal temperature exceedsdesign parameters for safe operation. The Cooling Fanwill automatically turn off when the temperature drops toa safe operating level....
Page 6 - INVERTER INFORMATION; Important Information About Your New Whistler Inverter.; Each of the following operating procedures; NOTE: Not recommended for use with medical equip-; IMPORTANT INFORMATION; Getting Started
INVERTER INFORMATION Important Information About Your New Whistler Inverter. This manual will provide you with directions for the safeand efficient operation of your Whistle Power Inverter. Important Note: Each of the following operating procedures and safety features must be carefully reviewed and ...
Page 7 - Selecting the Optimum Power Source.
start up load ratings comparable to your inverter wattagerating will not damage it. If a piece of equipment or an appliance will not operate,first confirm that the inverter has been properly connectedto the 12 volt power source (See "Making The Connection").If all connections have been prope...
Page 8 - BATTERY/CABLE INFORMATION; Wire Cable Gauges; BATTERY INFORMATION; To calculate the amp/hour of the battery, first determine
13 BATTERY/CABLE INFORMATION • It may be advisable to operate the inverter from a bankof batteries of the same type in a "parallel" configuration.Two such batteries will generate twice the amp/hoursof a single battery; three batteries will generate threetimes the amp/hours and so on. This mu...
Page 9 - Making the Connection.; Do not use tools to tighten these screws.
Adapter." Use of #0 gauge wire to make the connections tothe inverter may require a "0 to 4 Gauge Adapter." Bothadapters are available through electronic supply storesincluding Radio Shack. Radio Shack part number is listed below: O Ring Adapter: RSU11538139 0 to 4 Gauge Adapter: RSU1153...
Page 10 - Failure to heed
17 16 OPERATION OPERATION 7. Turn the inverter ON (I). Check the Meter on thefront panel. The Voltage should read between 11and 14 volts depending on the voltage of the powersource. If the reading is not within this range, checkthe voltage of the power source and the terminalconnections on the power...
Page 11 - Important Information on Battery Chargers
OPERATION OPERATION 18 • Check frequently to ensure that the input and output connections are secure. Loose connectionsmay damage the inverter, the power source, or may generate excessive heat. • The following precautions apply to the 3000 wattmodels only. a). The AC receptacles are equipped with 15...
Page 12 - For You Microwave Chefs.
21 20 OPERATION OPERATION problem short of purchasing a sound system with a higherquality power supply. For You Microwave Chefs. The power rating commonly associated with microwave ovensis the "cooking power" which is the power being "delivered"to the item being microwaved. The actua...
Page 13 - For You Technical Types.
OPERATING PRINCIPALS 23 22 OPERATION to moisture. Do not operate the inverter if you, theinverter, the device being operated or any other surfacesthat may come in contact with any power sources arewet. Water and many other liquids can conduct electricitywhich may lead to serious injury or death. • H...
Page 14 - OPERATION SUMMARY; Before attempting to use a battery charger see page 19.; OPERATING PRINCIPALS/SUMMARY; A true sine wave typical of home AC outlet.
OPERATION SUMMARY • Make certain the rated power consumption of the appliance or equipment you wish to operate is compatiblewith the capacity of your inverter. • If the rated power consumption of the equipment is inthe range of the maximum specified wattage of yourconverter, test the inverter to ens...
Page 16 - SPECIFICATION; TROUBLESHOOTING; Overload or High Temp LED on
SPECIFICATION WHISTLER 1200 WATT INVERTER SPECIFICATIONS Maximum Continuous Power……………………………1200 WattsMaximum Surge Capability (Peak Power).......................2400 WattsNo Load Current Draw………………………………...............0.50 AWaveform……………………………….............Modified Sine WaveOperating Input Voltage ...
Page 17 - • A copy of your dated store receipt or bill of sale.; Service Out Of Warranty; WARRANTY; Consumer Warranty; There are no express; Service Under Warranty; Whistler Repair Dept.; Please allow 3 weeks for return.
WARRANTY IMPORTANT: Whistler will not assume responsibility for lossor damage incurred in shipping. Therefore, please ship yourinverter insured with return receipt requested. 2. Include with your unit the following information, clearly printed:• Your name and street address (for shipping via UPS), a...
Page 18 - personal checks; . In the event repairs cannot be covered; Customer Service
MEMO 33 32 WARRANTY The out of warranty service fee for your 1200 Whistler inverteris $90.00, 2000 Whistler inverter is $150.00 and 3000 Whistlerinverter is $250.00. If you require out of warranty service,please return your inverter as outlined in the section “ServiceUnder Warranty” along with a cer...