Page 2 - Your warranty; only; by your; INTRODUCTION
1 If you have questions concerning theoperation of this Whistler productplease call customer service: 1-800-531-0004 Hours: Monday - Friday 8:00 am - 5:00 pm CT Please keep the receipt in a safe place.You may register your product online atwww.whistlergroup.com. If the unit isreturned without a date...
Page 3 - WHISTLER FEATURES; TABLE OF CONTENTS
WHISTLER FEATURES A Word About Whistler Power Inverters Whistler inverters convert low voltage, direct current (DC) to 110volt alternating household current (AC). The AC output is called“modified sine wave”. See “Technical Operating Principles”section for more information. Depending on the model and...
Page 6 - INVERTER INFORMATION; IMPORTANT INFORMATION; Getting Started
INVERTER INFORMATION IIm mp po orrtta an ntt IIn nffo orrm ma attiio on n About Your New Whistler Inverter. This manual will provide you with directions for the safe andefficient operation of your Whistle Power Inverter. IIm mp po orrtta an ntt N No otte e:: Each of the following operating procedure...
Page 7 - Selecting the Optimum Power Source.
start up load ratings comparable to your inverter wattagerating will not damage it. If a piece of equipment or an appliance will not operate,first confirm that the inverter has been properly connectedto the 12 volt power source (See "Making The Connection").If all connections have been prope...
Page 8 - BATTERY/CABLE INFORMATION; Wire Cable Gauges; BATTERY INFORMATION; To calculate the amp/hour of the battery, first determine
13 BATTERY/CABLE INFORMATION • It may be advisable to operate the inverter from a bankof batteries of the same type in a "parallel" configuration.Two such batteries will generate twice the amp/hoursof a single battery; three batteries will generate threetimes the amp/hours and so on. This mu...
Page 9 - Making the Connection.; Do not use tools to tighten these screws.
Adapter." Use of #0 gauge wire to make the connections tothe inverter may require a "0 to 4 Gauge Adapter." Bothadapters are available through electronic supply storesincluding Radio Shack. Radio Shack part number is listed below: O Ring Adapter: RSU11538139 0 to 4 Gauge Adapter: RSU1153...
Page 10 - Failure to heed
17 16 OPERATION OPERATION 7. Turn the inverter ON (I). Check the Meter on thefront panel. The Voltage should read between 11and 14 volts depending on the voltage of the powersource. If the reading is not within this range, checkthe voltage of the power source and the terminalconnections on the power...
Page 11 - Important Information on Battery Chargers; First, make certain that the television antenna produces
OPERATION OPERATION 18 • Check frequently to ensure that the input and output connections are secure. Loose connectionsmay damage the inverter, the power source, or may generate excessive heat. • The following precautions apply to the 3000 wattmodels only. To generate the maximum output, the 3000 wa...
Page 12 - Some Powerful Advice.
21 20 OPERATION OPERATION and typically is referenced on the back of the microwave. Ifthe operating power requirement does not appear on theback of the microwave, check the owner’s manual or contactthe manufacturer. Some Powerful Advice. Your Whistler inverter will work best when placed on a reasona...
Page 13 - For You Technical Types.
OPERATING PRINCIPALS 23 22 OPERATION radiators or other sources of heat. Do not place theinverter in direct sunlight. • VENTILATION. In order to disperse the heat generatedwhile the inverter is in operation, keep it well ventilated.While in use, maintain several inches of clearance aroundthe top and...
Page 14 - OPERATION SUMMARY; Before attempting to use a battery charger see page 19.; OPERATING PRINCIPALS/SUMMARY; A true sine wave typical of home AC outlet.
OPERATION SUMMARY • Before attempting to use a battery charger see page 19. • Before attempting to use medical equipment see page 8. • Use the heaviest gauge wire (smaller the number, thelarger or heavier the cable) available to connect theinverter to the power source. • When operating the inverter ...
Page 16 - SPECIFICATION; TROUBLESHOOTING; Overload or High Temp LED on
SPECIFICATION WHISTLER 1200 WATT INVERTER SPECIFICATIONS Maximum Continuous Power……………………………1200 WattsMaximum Surge Capability (Peak Power).....................2400 Watts**No Load Current Draw………………………………...............< 1.3AWaveform……………………………….............Modified Sine WaveOperating Input Volta...
Page 17 - • A copy of your dated store receipt or bill of sale.; Service Out Of Warranty; WARRANTY; Consumer Warranty; There are no express; Service Under Warranty; Whistler Repair Dept.; Please allow 3 weeks for return.
WARRANTY IMPORTANT: Whistler will not assume responsibility for lossor damage incurred in shipping. Therefore, please ship yourinverter insured with return receipt requested. 2. Include with your unit the following information, clearly printed:• Your name and street address (for shipping via UPS), a...
Page 18 - personal checks; . In the event repairs cannot be covered; Customer Service
MEMO 33 32 WARRANTY The out of warranty service fee for your 1200 Whistler inverteris $90.00, 2000 Whistler inverter is $150.00 and 3000 Whistlerinverter is $250.00. If you require out of warranty service,please return your inverter as outlined in the section “ServiceUnder Warranty” along with a cer...