Page 2 - Owner’s Manual; Standard Whirlpool Jet
2 Owner’s Manual Standard Whirlpool Jet SANIJET® Pipeless (Optional) PETRA 700 PETRA 700-S* PETRA 500 PETRA 500-S PETRA 450 PETRA 450-S PETRA 350R** or V*** PETRA 350R** or V***-S PETRA 300 PETRA 300-S S*=SANIJET® Pipeless R**=Roller Massage V***=Vibration Massage Table of Contents Introduction &...
Page 3 - WARNING; Massage should be pleasant and comfortable.
3 Introduction T hank you for purchasing the PETRA Whirlpool Pedicure Spa. T his finest Whirlpool Pedicure Spa has been developed by J&A USA, Inc . to operate dependably for many years when used properly. Please take time to read this entire manual thoroughly before installation and use. PLEASE ...
Page 5 - IDENTIFYING PARTS
STOP C O N T I N U E / R E P E A T THIGHMASSAGE AUTO TAP KNEAD U P DOWN MASSAGEWHEELS J&A A B 1 - PILLOW COVER 2 - BACK REST 3 - ARM REST 4 - MATCHING ARM TRAY (OPTIONAL) 5 - SEAT CUSHION 6 - SHOWER SPRAYER 7 - ADJUSTABLE FOOT CUSHION 8 - ON/OFF WHIRLPOOL BUTTON 9 - OPTIONAL ON/OFF BUTTON (LIGHT...
Page 6 - J A
PETRA 450, 350R, 350V & 300 J A & Pacific Spa TRANSFORMER MODEL:GRA 1215INPUT: AC 120V, 60Hz OUTPUT: DC 12V, 1.5A TRANSFORMER MODEL: GRA 1215INPUT: AC 120V, 60Hz OUTPUT: DC 12V, 1.5A TRANSFORMER MODEL: AD-57241200INPUT: 120V, AC 60Hz OUTPUT: 24V, DC 1.2A TRANSFORMER MODEL: MKD-57121500INPUT:...
Page 7 - PETRA 500 WITH PIPELESS SANIJET; CHAIR ASSEMBLY FOR PETRA 700 & 500 SERIES; IMPORTANT ASSEMBLY INSTALLATION; PRIOR TO USE
COLD HOT STOP CONTINUE/REPEAT THIGHMASSAGE AUTO TAP KNEAD UP DOWN MASSAGEWHEELS J&A A B FORWARD BACKWARD UP DOWN 1 2 3 4 5 6 7 8 1) LIGHT BOX POWER CORD2) SLIDER / RECLINER POWER CORD 3) SANIJET CONTROL BOX POWER CORD4) CHAIR MASSAGE POWER CORD5) HITCH PIN CLIP 6) RECLINING PISTON7) CLEVIS PIN 8...
Page 8 - Rear View; Channel Frame
COLD HOT COLD HOT COLD HOT 1) REMOVE THE LOCK NUT FROM THE BOLTS2) ALIGN FOUR BOLTS WITH FOUR HOLES ON THE CHANNEL FRAME3) TIGHTEN EACH LOCK NUTS TO SECURE THE CHAIR TO THE BASE PETRA 450 PETRA 300 PETRA 350R & 350V PETRA Chair Assembly for 450, 350R, 350V, 300 Washer Bolt Lock Nut Rear View CHA...
Page 9 - WALL; PETRA COLLECTION SPECIFICATIONS; Petra Collection Specifications
55 18 57 43 2.5 19 25 24 28 41 48 17 57 43 24 18 24 1.5 44 28 27 WALL PETRA 700 & 500 PETRA 450, 350R, 350V & 300 PETRA COLLECTION SPECIFICATIONS Due to continuous improvements on all our products; specifications, characteristics, packing, colors, designs are subject to change without notice...
Page 10 - Between Each Customer
10 Plumbing Connections All plumbing connections should be made by a qualified, licensed plumber in accordance with local plumbing and building codes. Hot and Cold Water Supply Lines Connect 1/2” ID supply tubes to a fresh water source. Shut-off valves should be utilized. Electrical Connections The ...
Page 11 - Warning; Assembly
11 FOR SANIJET® -PIPELESS SYSTEM USERS ONLY Maintenance Keep the screen of the jet inlet free of debris, any blockage of the screen reduces the whirlpool action and may cause damage to the jet motor. Cleaning Pipeless Jet System Remove the jet assembly from its casing: Rotate the jet assembly counte...
Page 12 - SYMTOMS
12 Caution To reduce the potential risk of fire, electrical shock, or injury to persons: 1) All electrical wiring (both installation & repair) must be done by a licensed electrician and in accordance with local and state ordinances. 2) No modifications, additions or deletions should be made to t...
Page 14 - ITEM; CAUTION; SYMPTOMS PROBABLE CAUSES RECOMMENDED ACTION; TROUBLE SHOOTING GUIDE
1 2 6 7 8 9 10 3 4 5 11 12 PUMP PARTS LIST ITEM PARTS# DESCRIPTION 1 WWVF FRONT VOLUTE 2 WWIMP IMPELLER 3 UPUFO/R UNION O RING 4 UPUFM UNION MALE 1 1/2" 5 UPUFF UNION FEMALE 1 1/2" 6 PPSSFSEAL SEAL ASSEMBLY 7 PPWWVB VOLUTE BACK 8 PPWWCORD POWER CORD 9 MPASHU506 AIR SWITCH 10 PPWWVO/R VOLUTE ...
Page 15 - Main Drain Pipe; Tub; FAQ; Discharge Pump Installation
Main Drain Pipe ON/OFF DISCHARGE SWITCH L-TRAP DISCHARGE PUMP POWER CORD CONVERTER BOX Check Valve must be installed to prevent back flow Tub - Outlet from drain pump must be placed on top of the main drain pipe - Do not use flexible pipe for drain Outlet FAQ 1) Pump hums but does not drain the wate...
Page 16 - When massage is not functional :; Lubrication; ) Turn off the main power; BACK VIEW; Caution; Do not apply lubrication on dc-belt
AC MOTOR PCB BOARD MAIN ON/OPF POWER SWITCH GEAR BOX DC-MOTOR MAIN SHAFT OIL RESERVOIR DC-PULLEY GEAR PULLEY DC-BELT UPPER SENSOR LOWER SENSOR IMPORTANT!!! LUBRICATE ON CIRCLED AREA MACHINERY OIL RECOMMENDED REMOVE SCREWS (PHILLIP)TO OPEN THE PANEL TRANSFORMER FUSE Always check your power source fir...
Page 18 - MULTI-COLOR LED SPA LIGHT; To change a bulb after installation,; INSERT TOOL; Pull bulb straight out; Figure 1; Drain spa and disconnect power before attempting to open lens.
MULTI-COLOR LED SPA LIGHT (Instruction for LED Bulb replacement) Multicolor LED spa lights allows the replacement of the lamp from the front. It comes complete with a plastic insert tool for tightening, or un-tightening. NOTE: To change a bulb after installation, follow the instruction engraved on t...
Page 19 - Plumbing Accessories; Whirlpool pedicure spas
Plumbing Accessories Whirlpool pedicure spas , Models PS300 , PS650LX, Episode , Episode -S Type, Toepia EM , Cleo , Petra. This page and all contents are Copyright © 2005 by Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that...