Page 2 - CONTENTS
Congratulations and thank you for choosing our Product. We are sure you will find your new cooktop a pleasure to use and a great asset to your cooking. Before you use the cooktop, we recommend that you read through the whole user manual which provides the description of the cooktop and its functions...
Page 3 - iMPORTANT SAFETY iNSTRUCTiONS; SAFETY
3 Please read the us er manual carefully and store in a handy place for later reference. The symbols you will see in this booklet have these meanings: WARNING This sym bol indicates information concerning your personal safety CAUTION This symbol indicates information on how to avoid damaging the app...
Page 4 - iNSTALLATiON; USiNG YOUR COOKTOP
iNSTALLATiON NO TE: You must read these warnings carefully before installing or using the cooktop. If you need assistance, contact your Customer Care Department. The manufacturer will not accept liability, should the instructions below or any other safety instructions incorporated in this book be ig...
Page 6 - TROUBLESHOOTiNG
TROUBLESHOOTiNG FAULT POSSiBLE CAUSES REMEDY Burner will not light even though the sparker is working . • Knob not held down long enough in ‘High’ position for flame safeguard (where fitted) to engage • Repeat lighting procedure and hold knob down for 5 seconds in ‘High’ position (refer page 4) • Ga...
Page 7 - iNSTALLATiON iNSTRUCTiONS
7 480mm 560mm * Gas supply connection location 830mm Gas supply connection location * 480mm Figure 4–60cm and 75cm models cut-out Figure 4–90cm models cut-out iNSTALLATiON iNSTRUCTiONS This applia nce must be installed by an authorised person and in compliance with : 1. AS 5601 ‘Gas Installations’ (...
Page 8 - iNSTALLATiON PROCEDURE
iNSTALLATiON 1. The b ench cutout should be made as per cutout dimensions in Figure 4. 2. Adjacent walls, cupboards and protection for combustible materials. Ensure that the appliance is installed with Section 5.12.1 of AS 5601 (Australia) or section 14.1 of NZS 5261 (New Zealand), regarding clearan...
Page 10 - GAS CONNECTiON
OPERATiON ON N.G./S.N.G . GAS CONNECTiON This ap pliance is supplied for use with Natural Gas. However, it can be converted for use with LPG. Refer to LP conversion on pages 12 and 13. Supply pipe sizing The total hourly gas consumption for the appliance is shown on the data label. The required supp...
Page 12 - LPG CONVERSiON
CAUTION This a ppliance is fitted with Natural Gas burner injectors. Please follow the procedure below if a conversion to suit LP gas is required. The conversion kit contains appropriate LPG injectors and 1 LPG sticker. To convert to LPG 1. Remove the hotplate burners to access the hotplate injector...
Page 14 - TESTiNG APPLiANCE OPERATiON
TESTiNG APPLiANCE OPERATiON After installation, tes t the appliance and ensure that it operates correctly before handing it over to the customer. The following procedure is recommended: 1. Turn on the gas and electricity supply and attempt ignition on all burners, both separately and in combination....
Page 15 - WARRANTY
15 Important Notice Before Calling a Service Technician please check carefully the operating instructions, service booklet and the warranty terms and conditions. FOR SERVICE or to find the address of your nearest state service centre in Australia PlEaSE Call 13 13 49 For the cost of a local call (Au...