Page 2 - WARNINGS
2 DANGERS & WARNINGS DANGER Failure to follow the Dangers, Warnings and Cautions contained in this Owner’s Manual may result in serious bodily injury or death, or in a fi re or an explosion causing damage to property. WARNINGS Do not store a spare or disconnected liquid propane cylinder under or...
Page 3 - WARRANTY; Warranty; Storage
3 WARRANTY Warranty Weber-Stephen Products Co. (Weber) hereby warrants to the ORIGINAL PURCHASER of this Weber ® gas grill that it will be free of defects in material and workmanship from the date of purchase as follows: when assembled and operated in accordance with the printed instructions accompa...
Page 4 - Side Burner; WARNING: All counter top fi nished surfaces must be; GAS INSTRUCTIONS
4 LOCATING YOUR BUILT-IN SIDE BURNER When determining a suitable location for your Built-In Side Burner installation, give attention to concerns such as exposure to wind, proximity to traffi c paths, and keeping any gas supply lines as short as possible. Never locate the Summit ® Built-In Side Burne...
Page 5 - DANGER; BUILT-IN GAS LINE LOCATIONS; Built-In side burner unit should be on site
5 MOUNTING THE SIDE BURNER Connect the corrugated gas line to the side burner valve located on the back right hand side of side burner. Test connections All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of AN...
Page 6 - Caution: If young children are in the area, a locking; GAS LINE PIPING
6 GAS INSTRUCTIONS Table 10-1 Maximum Capacity of Pipe in Cubic Feet of Gas per Hour for Gas Pressures of 0.5 psi or Less and a Pressure Drop of 0.3 Inch Water Column. (Based on a 0.60 Specifi c Gravity Gas) Nominal Iron Pipe Size (Inches) Internal Diameter (Inches) Length of Pipe (Feet) 10 20 30 40...
Page 7 - CONNECT GAS SUPPLY; REGULATOR
7 Regulator Hard piped gas supply top view Figure 1 Cap (Optional Side Burner) Regulator to side burner Hard piped gas supply top view Figure 2 CONNECT GAS SUPPLY 1) Uncap the fl are fi tting from the optional side burner connection located at regulator. Note: You must connect your side burner to a ...
Page 8 - Side Burner Lighting Instructions; Lighting the side burner.; CAUTION: Side burner fl ame may be diffi cult to see
8 GAS INSTRUCTIONS TOSIDEBURNER TOREGULATOR TOPVIEW Check: 1) Corrugated gas line-to-Accessory “T” Connection.2) Main gas Supply to regulator WARNING: If there is a leak a connection(1), retighten the fi tting with a wrench and recheck for leaks with soap and water solution. If a leak persists after...
Page 9 - OPERATING; Manually Lighting the Side Burner; To Extinguish
9 OPERATING Manually Lighting the Side Burner DANGER Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive fl ame-up which can cause serious bodily injury or death. 1) Open the side bur...
Page 10 - Side Burner does not light.; Side Burner maintenance; WARNING: All gas controls and supply valves; SIDE BURNER TROUBLESHOOTING
10 Problem Check Cure Side Burner does not light. Is gas supply off? Turn supply on. Flame is low in HIGH position. Is the fuel hose bent or kinked? Straighten gas line. Push button ignition does not work. Does burner light with a match? If match lights burner, check igniter (see below). If problems...