Page 2 - WARNINGS
2 DANGERS & WARNINGS DANGER Failure to follow the Dangers, Warnings and Cautions contained in this Owner’s Manual may result in serious bodily injury or death, or in a fi re or an explosion causing damage to property. WARNINGS Do not store a spare or disconnected liquid propane cylinder under or...
Page 3 - WARRANTY; Stainless Steel Lid,
3 STORAGE AND/OR NONUSE • The gas must be turned off at the liquid propane cylinder when the Weber ® gas barbecue is not in use. OPERATING WARNING: Only use this barbecue outdoors in a well-ventilated area. Do not use in a garage, building, breezeway or any other enclosed area. WARNING: Your Summit®...
Page 4 - LOCATING YOUR BUILT-IN SIDE BURNER; WARNING: Clearance from the outside walls of the; ace; Side; BUILT-IN SRUCTURE CUTOUT DIMENSIONS; WARNING: All counter top fi nished surfaces must be; GAS INSTRUCTIONS; Side Burner
4 LOCATING YOUR BUILT-IN SIDE BURNER When determining a suitable location for your Built-In Side Burner installation, give attention to concerns such as exposure to wind, proximity to traffi c paths, and keeping any gas supply lines as short as possible. Never locate the Sum-mit ® Built-In Side Burn...
Page 5 - DANGER
5 MOUNTING THE SIDE BURNER Connect the corrugated gas line to the side burner valve located on the back right hand side of side burner. TEST CONNECTIONS All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of AN...
Page 6 - TYPICAL BULK PROPANE GAS SUPPLY INSTALLATION; CAUTION: If young children are in the area, a; GAS LINE PIPING
6 TYPICAL BULK PROPANE GAS SUPPLY INSTALLATION We recommend that this installation be done by a LICENSED professional.General Specifi cations for PipingNote - Contact your local municipality for building codes regulating outdoor gas grill installations. In absence of Local Codes, you must conform to...
Page 7 - TYPICAL 20 LP PROPANE GAS SUPPLY INSTALLATION; TEST CONNECTIONS
7 TYPICAL 20 LP PROPANE GAS SUPPLY INSTALLATION We strongly recommend that you use the Summit ® Built-In Tank Cabinet (#21280) for installations using a 20 lb LP cylinder, mounted remotely in an “island” structure.The Summit ® Built-In Tank Cabinet is a CSA listed accessory for installing a remote m...
Page 8 - CONNECT GAS SUPPLY
8 3). The minimum size of the ventilation hole (s) should not be less than 1/4 inch. d). The remote LP cylinder enclosure should be constructed with non- combustible materials. The remote LP cylinder enclosure should isolate the LP cylinder from the burner compartment, so that it provides shielding ...
Page 10 - CHECK FOR GAS LEAKS
10 To Connect the hose to the cylinder: 3) Remove the plastic dust cover from the valve. 4) Screw the regulator coupling onto the tank valve, clockwise, or to the right. Hand-tighten only. Note: This connection tightens clockwise and will not allow gas to fl ow unless the connection is tight. The co...
Page 11 - OPERATING; SAFE HANDLING TIPS FOR LIQUID PROPANE GAS CYLINDERS; WARNING: We recommend that your LP cylinder be; CAUTION: When transporting the LP cylinder make
11 Check: 3) “T” Connection-to-Hose connections. 4) The hose-to-Regulator connection. WARNING: If there is a leak at connections (2,3, or 4), turn OFF the gas. DO NOT OPERATE THE GRILL. Contact Customer Service 1-800-446-1071. When leak checks are complete, turn gas supply OFF at the source and rins...
Page 12 - LIGHTING THE SIDE BURNER.; WARNING: The burner control knob must be in the; SIDE BURNER LIGHTING INSTRUCTIONS; CAUTION: Side burner fl ame may be diffi cult to see; TO EXTINGUISH
12 LIGHTING THE SIDE BURNER. 1) Open the side burner lid. 2) Check that the side burner valve is turned OFF. (Push knob in and turn clockwise to ensure that it in the off position.) WARNING: The burner control knob must be in the OFF position before turning on the liquid propane cylinder valve. If i...
Page 13 - MAINTENANCE; MANUALLY LIGHTING THE SIDE BURNER
13 CROSSOVER ® IGNITION SYSTEM OPERATIONS If the Crossover ® ignition system fails to ignite the LEFT burner in a burner set, light the LEFT burner with a match. If the LEFT burner lights with a match, then check the Crossover ® ignition system. • Check that both ignition wires(1,2) are attached pro...
Page 14 - SIDE BURNER MAINTENANCE; WARNING: All gas controls and supply valves should be; SIDE BURNER TROUBLESHOOTING; PROBLEM
14 SIDE BURNER MAINTENANCE WARNING: All gas controls and supply valves should be in the OFF position. Make sure wire is connected between the igniter and electrode. Spark should be a white/blue color, not yellow. 1) Igniter Wire 2) Burner (3) Side Burner Grate Side Burner Cap Side Burner Ring & ...
Page 15 - country designation located on outer carton.
15 ATTENTION: This product has been safety tested and is only certifi ed for use in a specifi c country. Refer to country designation located on outer carton. These parts may be gas carrying or gas burning components. Please contact Weber-Stephen Products Co., Customer Service Department for genuine...