Page 2 - CONTENTS; Page
CONTENTS Page 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2. Functions which Require Additional Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3. Precautions...
Page 3 - or; WHICH REQUIRE ADDITIONAL UNITS
1. INTRODUCTION This manual forms part of the Installation Manual for TOA INTERCOM SYSTEM EXES-1000. You may add to the CCU-11B to your TOA INTERCOM SYSTEM EXES-1000, according to your specific needs, to obtain various other functions. Correct operation of these additional functions are not availabl...
Page 4 - P R O G R A M SWITCH for No. 11 Programming
Please read following instructions carefully to ensure proper operation of the CCU-11B. 1. Be careful about damage by static electricity as the CCU-11B incorporates CMOS IC's. Do not touch com- ponents and connectors. 2. Turn off the AC power switch when you take out or insert the CCU-11B unit or an...
Page 5 - INITIAL CCU-11B SET UP; Touch ten times
4 INITIAL CCU-11B SET UP Make sure that you have turned off the AC power switch. Remove the CCU card from the card rack of exchange. Set mini-jumper on the CCU card to "BATT. ON" position. Set function selection DIP switches (SW-A & SW-B) on the CCU card forrequired functions. Insert the...
Page 6 - sw
5 DIP SWITCH FOR FUNCTION SELECTION ON CCU-11B The DIP switches on the CCU-11B allow selection of the following functions; Switches Functions DIP-SW "ON "Position DIP-SW "OFF "Position Mini-Jumper for Battery Battery "ON" Position Battery "OFF" Position OFF OFF Remote...
Page 7 - NO. 11 PROGRAMMING FOR EACH FUNCTION; Yes
6. STATION NO. 11 PROGRAMMING FOR EACH FUNCTION Use station #11 for programming of "Continuous Calling Tone", "Secretary Transfer", "Master/Sub-Relationship" and/or "Executive Priority" functions. Remarks: 1. In the event of failure to touch keys for correct dialing, ...
Page 10 - In the case of power ON/OFF remote control.
7-2. Connections A. Connect 4-pin connector from TBM-11 (Terminal module) to P2 connection socket on the CCU-11B. B. R M 1 terminals on TBM-11 are for the door remote control relay contacts and RM 2 terminals on TBM-11 are for the power ON/OFF remote control or press to talk remote control relay con...
Page 11 - PROGRAMMING LIST FOR FUNCTIONS; Function Table for Stations; Functions
8. PROGRAMMING LIST FOR FUNCTIONS Use these tables to keep a record of those functions assigned to each station. Function Table for Stations Functions Name 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Continuous Calling Tone Executive Priority Secre...