Page 2 - Installation Instructions; INTRODUCTION; TABLE 1; Option; Mono; Supply
2 Installation Instructions INTRODUCTION Read all of these instructions. Use them to install your camera and have them available for its lifetime. If you have any problems, contact your agent. Note that not all cameras have all of the features described in this manual. Refer to the table below for t...
Page 3 - PRODUCT SAFETY; experienced personnel.; purpose. Only operate your camera between the temperatures of -10
3 Installation Instructions PRODUCT SAFETY Installation and servicing is only to be carried out by suitably qualified and experienced personnel. Mains cameras contain hazardous voltages. Do not remove covers as there is a risk of injury or death by electric shock. Cameras connected to mains su...
Page 4 - CAUTIONS
4 Installation Instructions CAUTIONS In order to avoid damaging the camera note the following points:1) The camera has threaded mounting points on the top and bottom of the case. Only use a standard, photographic, mounting-bolt with a 1/4 20 UNC thread. 2) Before fitting the lens make sure that its...
Page 5 - CONTROLS AND SWITCHES
5 Installation Instructions CONTROLS AND SWITCHES On the side of the camera is a hinged flap. The hinged flap covers various adjustment controls and function switches. 1 1 2 2 3 3 4 4 6 7 (8) (10) (11a) (12) (13) (9) 5 (11b) (12) (13) 230 VAC MODELS COLOUR CAMERAS MONO CAMERAS LOW VOLTAGE MODELS (1)...
Page 6 - ON; when using fixed or manual iris lenses. When; OFF; accordance with the diagram below:; (10) Electronic Iris and DC Lens Level Adjustment Potentiometer
6 Installation Instructions CONTROLS AND SWITCHES (4) Electronic Iris (EI) The Electronic Iris (EI) compensates for excessive light level by automatically adjusting the shutter speed. The electronic iris should be ON when using fixed or manual iris lenses. When using Auto Iris (AI) lenses of either ...
Page 7 - Only connect the camera to a class 2 power supply; = Lens positive supply; a 75 Ohm BNC connector to the BNC socket marked VIDEO OUT.
7 Installation Instructions CONTROLS AND SWITCHES output for a typical scene. The level should not be adjusted unless absolutely necessary. (11a) Supply Voltage Terminals This terminal accepts an 11-40 VDC or 14-30 VAC at 50Hz (CCIR/PAL) or 60Hz (EIA/NTSC) power source. Ther terminals are the quick ...
Page 8 - LENS SELECTION; LENS SETUP PROCEDURES; Auto Iris Lenses; FOCUS ADJUSTMENT; The last turn; over turn the back focus mechanism.; Fixed Lenses; using the back focus screw. Set the lens focus as required.; Manual Iris Lenses
8 Installation Instructions LENS SELECTION Suitable lens types are C and CS mount in fixed iris, manual iris, auto iris or direct drive versions. Sizes are shown below. Cameras are factory set for CS mount lenses. If using a C mount lens, rotate either of the back focus screws approximately 30 turns...
Page 9 - Auto Iris and Direct Drive Lenses; with the minimum loss of focus.
9 Installation Instructions FOCUS ADJUSTMENT Auto Iris and Direct Drive Lenses Fully open the iris by covering the lens with a suitable neutral density (ND) filter. Set the lens focus to infinity. View an image greater than 7 feet (2 meters) away. Focus the image using the back focus screw. Remove t...
Page 12 - Norbain SDL Limited
HB-PROTOS3D-6 Issue 6 04/02 Norbain SDL Limited Norbain House, Eskdale Road, Winnersh Triangle, Wokingham, Berkshire RG41 5TS Norbain SDL Limited reserve the right to make changes to the product and specification of the product from time to time without prior notice