Page 3 - Important Safety Information; A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED.
- 2 - Important Safety Information • DO NOT USE A GROUND FAULT INTERRUPTER (GFI). • A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED.
Page 4 - Feature Description
- 3 - Feature Description • Wine-Mate split cooling systems VINO2500-8500SSH are designed and used to provide a cold temperature between 50~65 ° F for a properly insulated wine room at a normal environment. • The wine room will maintain humidity of 50~70% RH even when the environment becomes dry and...
Page 7 - Cellar Construction; F in the wine cellar, the ambient temperature
- 6 - Cellar Construction This is only a guide and shall be considered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R11 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation. The vapor barrier shall...
Page 8 - Installer’s Instruction; Federal law requires that WINE-MATE split cooling systems be
- 7 - Installer’s Instruction Federal law requires that WINE-MATE split cooling systems be installed by an EPA certified refrigeration technician. WINE-MATE split system is shipped as components and is ready for use only after a certified refrigeration technician has properly installed, charged and ...
Page 9 - Refrigeration Piping and Charging
- 8 - 1. Condensing Unit • Place the condensing units WM250-850SCU in a properly ventilated location. If it is not, heat exhausted by the condensing unit will build up and the cooling system will not operate properly. • Leave minimum 5 feet clearance for the exhaust side and leave minimum 1 foot cle...
Page 10 - Pressure, Superheat and Subcooling Readings
- 9 - • The evaporator’s constant pressure expansion valve is set around 38- 40 ° F at factory. This pressure setting gives a dew point to maintain the humidity for storing wine. • The superheat at the evaporator unit shall be around 9-18 ° F under low and high load at 75 ° F ambient temperature. • ...
Page 11 - Back Position; : Process and manometer port closed for normal operation; Front Position; : Main connection to liquid or suction line closed; Middle Position; : All ports open for vacuum, charge and measurement
- 10 - High superheat and high subcooling n. Low suction pressure and high head pressure High superheat and high subcooling o. low to normal suction pressure and high head pressure High to normal superheat and high subcooling restricted n. Liquid line restricted before receiver o. Condenser restrict...
Page 12 - Electrical Wiring
- 11 - 7. Electrical Wiring Fig. 2.3 VINO2500 & 4500SSH Electrical Wiring Diagram (VTSTAT) Fig. 2.4 VINO2500 & 4500SSH Wiring Diagram (DIGITAL CONTROLLER)
Page 16 - Temperature Control & Humidity Adjustment; Temperature Setting
- 15 - Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 ° F for the optimum aging of wine • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantity of bottles, temperature setting and surrounding tem...
Page 19 - Code Description
- 18 - 2) Alarm Signals 2.1 Code Description 2.2 Alarm Recovery Probe alarms P1”, start a few seconds after the fault in the related probe; they automatically stop a few seconds after the probe restarts normal operation. Check connections before replacing the probe. Temperature alarms “HA”, “LA” aut...
Page 21 - Care Guide; Unplug the system or disconnect power.; Moisture Removing
- 20 - Care Guide In general, always unplug system or disconnect power while doing care. 1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Unplug the system or disconnect power. • Use a vacuum cleaner with an extended attachment to clean th...
Page 22 - User’s Troubleshooting
- 21 - User’s Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive Troubleshooting Chart Complaint Possible Causes Response 1.Unit not running a. No power b. Power cord unplugged c. Settin...
Page 24 - Customer Support
- 23 - Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: [email protected]
Page 25 - Warranty; Thank you for choosing a Vinotemp cooling unit.; Limited Warranty
- 24 - Warranty Thank you for choosing a Vinotemp cooling unit. Please enter the complete model and serial numbers in the space provided: Model_________________________________________________________ Serial No.______________________________________________________ Attach your purchase receipt to th...
Page 26 - Limitation of Implied Warranty
- 25 - VINOTEMP will, at its discretion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect. 2. Limitation of Implied Warranty VINOTE...