Page 2 - READ AND SAVE THESE INSTRUCTIONS; TABLE OF CONTENTS
- 1 - READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Important Safety Information…..........................................2 Feature Description…………………………….……………..3 Cellar Construction.…………………………….……………..5 Installer’s Instruction…………….…..….……..……………..6 Temperature Control & Humidity Adjustm...
Page 3 - Important Safety Information; A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED.
- 2 - Important Safety Information • DO NOT USE A GROUND FAULT INTERRUPTER (GFI). • A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED.
Page 4 - Feature Description
- 3 - Feature Description • WINE-MATE ducted system VINO4500-8500DS are designed and used to provide a cold temperature between 50~65 ° F for a properly insulated wine room at a normal environment. • The wine room will maintain humidity of 50~70% RH even when the environment becomes dry and humid. T...
Page 6 - Cellar Construction; F in the wine cellar, the ambient temperature
- 5 - Cellar Construction This is only a guide and shall be considered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R11 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation. The vapor barrier shall...
Page 7 - Installer’s Instruction; Federal law requires that WINE-MATE ducted cooling systems
- 6 - Installer’s Instruction Federal law requires that WINE-MATE ducted cooling systems be installed by an EPA certified refrigeration technician. WINE-MATE ducted system is shipped ready for use only after a certified refrigeration technician has properly installed the system. Proper installation ...
Page 8 - Evaporator Unit Air Flow
- 7 - 1. Location • Place the unit in a properly ventilated location. If it is not, heat exhausted by the condensing unit will build up and the cooling system will not operate properly. • Leave minimum 5 feet clearance for hot air exhaust and leave minimum 1 foot clearance for the fresh air intake. ...
Page 9 - Temperature Control & Humidity Adjustment; Temperature Setting
- 8 - Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 ° F for the optimum aging of wine • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantity of bottles, temperature setting and surrounding temp...
Page 14 - Service Guide; Pressure, Superheat and Subcooling Readings
- 13 - Service Guide 1. Refrigeration Piping and Charge • The subcooling at the condensing unit shall be around 10 ° F. The charge may be complete when there are no more bubbles forming in the sight glass. • The evaporator’s constant pressure expansion valve is set around 38- 40 ° F at factory. This...
Page 15 - Back Position; : Process and manometer port closed for normal operation; Front Position; : Main connection to liquid or suction line closed; Middle Position; : All ports open for vacuum, charge and measurement
- 14 - k. Low suction pressure and low to normal head pressure High superheat and normal to high subcooling l. Low suction pressure and normal head pressure High superheat and normal subcooling m. Low suction pressure and high head pressure High superheat and high subcooling n. Low suction pressure ...
Page 16 - Electrical Wiring
- 15 - 4. Electrical Wiring Fig. 4.2 VINO4500DS Electrical Wiring Diagram (VTSTAT) Fig. 4.3 VINO4500DS Electrical Wiring Diagram (DIGITAL CONTROLLER)
Page 20 - Care Guide; Unplug the system or disconnect power.; Moisture Removing
- 19 - Care Guide In general, always unplug system or disconnect power while doing care. 1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Unplug the system or disconnect power. • Use a vacuum cleaner with an extended attachment to clean th...
Page 21 - User’s Troubleshooting
- 20 - User’s Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive Troubleshooting Chart Complaint Possible Causes Response 1.Unit not running a. No power b. Power cord unplugged c. Settin...
Page 23 - Customer Support
- 22 - Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: [email protected]
Page 24 - Warranty; Thank you for choosing a Vinotemp cooling unit.; Limited Warranty
- 23 - Warranty Thank you for choosing a Vinotemp cooling unit. Please enter the complete model and serial numbers in the space provided: Model_________________________________________________________ Serial No.______________________________________________________ Attach your purchase receipt to th...
Page 25 - Limitation of Implied Warranty
- 24 - VINOTEMP will, at its discretion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect. 2. Limitation of Implied Warranty VINOTE...