Page 2 - Important Safety Information; DO NOT PLUG IN UNTIL 24 HOURS AFTER DELIVERY.
- 1 - Important Safety Information • DO NOT PLUG IN UNTIL 24 HOURS AFTER DELIVERY. • DO NOT USE A GROUND FAULT INTERRUPTER (GFI). • A DEDICATED 15 OR 20 AMPCIRCUIT IS HIGHLY RECOMMENDED.
Page 4 - Feature Description; F for suitable space at a normal environment.
- 3 - Feature Description • HZD cooling unit is designed and used to provide a stable temperature between 50~65 ° F for suitable space at a normal environment. • The refrigerated space will maintain humidity of 50~70% RH even when the environment becomes dry and humid. • These temperatures and humil...
Page 6 - Installation Instruction; F or lower than
- 5 - Installation Instruction Select a place to mount the unit where the exhaust airflow is unobstructed for a minimum of 6 inch. The area into which the unit exhausts must be well ventilated. If it is not, heat exhausted by the unit will build up and the unit will not operate properly. The ambient...
Page 12 - Cellar Construction; F in the wine cellar, the ambient temperature; ) DO NOT INSTALL ANY DUCTS ONTO THE SUPPLY, INTAKE ANY
- 11 - 3. Cellar Construction This is only a guide and shall be considered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R11 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation. The vapor barrier s...
Page 13 - Temperature Control & Humidity Adjustment; Temperature Setting
- 12 - Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 ° F for the optimum aging of wine • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantity of bottles, temperature setting and surrounding tem...
Page 17 - Care Guide; Coil is on the ambient air intake side of the cooling unit.; Moisture Removing; humidity condition.
- 16 - Care Guide 1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Coil is on the ambient air intake side of the cooling unit. • Unplug the unit or disconnect power. • Use a condenser brush or a vacuum cleaner with an extended attachment t...
Page 18 - Troubleshooting
- 17 - Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive Troubleshooting Chart Complaint Possible Causes Response 1.Unit not running a. Power cord unplugged b. No power to unit c. Setti...
Page 21 - Wiring Diagram
- 20 - Wiring Diagram Fig. 6.1 VINO1500-2500HZD Wiring Diagram Fig. 6.2 VINO1500-2500HZD CALLING FEATURE WIRING DIAGRAM
Page 23 - Customer Support
- 22 - Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: [email protected]
Page 24 - Warranty; Thank you for choosing a Vinotemp cooling unit.; Limited Warranty
- 23 - Warranty Thank you for choosing a Vinotemp cooling unit. Please enter the complete model and serial numbers in the space provided: Model_________________________________________________________ Serial No.______________________________________________________ Attach your purchase receipt to th...
Page 25 - Limitation of Implied Warranty
- 24 - is determined to be faulty and is within the twelve month warranty period VINOTEMP will, at its discretion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it ...