Page 3 - Important Safety Information; A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED.
- 2 - Important Safety Information • DO NOT USE A GROUND FAULT INTERRUPTER (GFI). • A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED.
Page 4 - Feature Description
- 3 - Feature Description • Wine-Mate split cooling systems VINO2500-6500SSR are designed and used to provide a cold temperature between 50~65 ° F for a properly insulated wine room at a normal environment. • The wine room will maintain humidity of 50~70% RH even when the environment becomes dry and...
Page 7 - Cellar Construction; F in the wine cellar, the ambient temperature
- 6 - Cellar Construction This is only a guide and shall be considered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R11 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation. The vapor barrier shall...
Page 8 - Installer’s Instruction; Federal law requires that WINE-MATE split cooling systems be; Place the condensing units WM250-650SCU in a properly ventilated
- 7 - Installer’s Instruction Federal law requires that WINE-MATE split cooling systems be installed by an EPA certified refrigeration technician. WINE-MATE split system is shipped as components and is ready for use only after a certified refrigeration technician has properly installed, charged and ...
Page 9 - Refrigeration Piping and Charging
- 8 - • Supply and return air flow from the evaporator unit shall be unobstructed for at least 1 foot. • There is a gravity drain line so that it can not be installed above the evaporator unit. Otherwise a condensation pump must be used. 3. Air Sensor • The air sensor can be located in the wine room...
Page 10 - Pressure, Superheat and Subcooling Readings
- 9 - 5. Pressure, Superheat and Subcooling Readings NOTES: THE VALVES MUST BE IN THE MIDDLE POSITIONS TO READ PROPERLY. Complaint Possible Causes a. High suction pressure and low head pressure b. High suction pressure and low head pressure Low superheat and low subcooling c. High suction pressure a...
Page 11 - Back Position; : Process and manometer port closed for normal operation; Front Position; : Main connection to liquid or suction line closed; Middle Position; : All ports open for vacuum, charge and measurement; Electrical Wiring
- 10 - Back Position : Process and manometer port closed for normal operation Front Position : Main connection to liquid or suction line closed Middle Position : All ports open for vacuum, charge and measurement 7. Electrical Wiring Fig. 2.2 VINO2500-4500SSR Electrical Wiring Diagram (VTSTAT)
Page 13 - Use of the adjustable low pressure control (if applicable)
- 12 - Fig. 2.5 VINO6500SSR Electrical Wiring Diagram (DIGITAL CONTROLLER) 8. Use of the adjustable low pressure control (if applicable) Cut out = 5 psig; Cut in = 25 psig; Differential = 20 psig It may need to adjust the setting in the field to get the right cycle time. Fig. 2.6 Adjustable Pressure...
Page 15 - Temperature Control & Humidity Adjustment; Temperature Setting
- 14 - Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 ° F for the optimum aging of wine • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantity of bottles, temperature setting and surrounding tem...
Page 20 - Care Guide; Unplug the system or disconnect power.; Moisture Removing
- 19 - Care Guide In general, always unplug system or disconnect power while doing care. 1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Unplug the system or disconnect power. • Use a vacuum cleaner with an extended attachment to clean th...
Page 21 - User’s Troubleshooting
- 20 - User’s Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive Troubleshooting Chart Complaint Possible Causes Response 1.Unit not running a. No power b. Power cord unplugged c. Settin...
Page 23 - Customer Support
- 22 - Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: [email protected]
Page 24 - Warranty; Thank you for choosing a Vinotemp cooling unit.; Limited Warranty
- 23 - Warranty Thank you for choosing a Vinotemp cooling unit. Please enter the complete model and serial numbers in the space provided: Model_________________________________________________________ Serial No.______________________________________________________ Attach your purchase receipt to th...
Page 25 - Limitation of Implied Warranty
- 24 - VINOTEMP will, at its discretion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect. 2. Limitation of Implied Warranty VINOTE...