Page 2 - W A R N I N G; Table of Contents; Please Read and Follow!
3 NOTE: If installing hood with warming shelf panel, installwarming shelf panel first. IMPORTANT – PLEASE READ AND FOLLOW • Before beginning, please read these instructions completely and carefully. • Do not remove permanently affixed labels, warnings, or plates from the product. This may void the w...
Page 3 - IMPORTANT–; Dimensions & Specifications; C A U T I O N
5 4 21” (53.3 cm) A 10” (25.4 cm) 12 ” (30.5 cm) A (Hood width) 30”W. 29-7/8“ (76.2 cm) 36”W. 35-7/8” (91.1 cm) 5” (12.7 cm) 21” (53.3 cm) A 12 ” (30.5 cm) A (Hood width) 30”W. 29-7/8“ (76.2 cm) 36”W. 35-7/8” (91.1 cm) 5” (12.7 cm) 12 ” (30.5 cm) (VWH 10” H./12”H. Wall Hoods w/Standard Ventilator 30...
Page 4 - 60 CFM Interior Ventilator Installation; Clearance Dimensions; Interior Ventilator Dimensions
6 7 * NOTE: When installing with a 24” high-shelf, the 27” (68.6 cm) max. dimensions must be used. 24”min. (61.0 cm) to 27”max.* (68.6 cm) 60”min. (152.4 cm) to 63”max. (160.0 cm) 36” (91.4 cm) A B C D 18” (4.6 cm) 3-7/8” (9.8 cm) 3-4” (1.9 cm) 7” (17.8 cm) dia. duct location Electrical hookup 1/2” ...
Page 7 - VWHO 18”H. Outdoor Wall Hoods
13 12 27” (68.6 cm) A 18” (45.7 cm) 12” (30.5 cm) 6” (15.2 cm) A (Hood width) 36”W. 35-7/8” (91.1 cm) 48“W. 47-7/8” (121.6 cm) 60”W. 59-7/8” (152.1 cm) Seal joints with silicone. Provided on “T” Series only. (VWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”) * A 1,200 CFM interior- or exterior-powe...
Page 8 - VCWH Chimney Wall Hoods
15 14 24” (61.0 cm) B A 18” (45.7 cm) 12” (30.5 cm) to 24” (61.0 cm) 6” (15.2 cm) A (Duct width) 30”W. 12“ (30.5 cm) 36”W. 12“ (30.5 cm) 42”W. 12“ (30.5 cm) 48“W. 18“ (45.7 cm) 60”W. 24“ (61.0 cm) 66”W. 24“ (61.0 cm) B (Hood width) 30”W. 29-7/8“ (76.2 cm) 36”W. 35-7/8” (91.1 cm) 42”W. 41-7/8” (106.4...
Page 10 - VCIH Chimney Island Hoods
19 18 * A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill. Max duct run is 50 ft (15.2 m). ** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft (22.9 m). NOTE: Maximum amp rating...
Page 12 - Wall Hoods; Custom Hood; Custom Hood Canopy Bottom Cutout Dimensions
23 22 (VBCV Wall Custom Ventilator System 36”, 42”, 48”, & 60”) 21-7/16” (54.5 cm) A* *For best results, center the unit over the burners of the cooking product (front to back; right to left). Wall Hoods Description A (Hood Width) 36” W. 33-7/16” (84.9 cm) 42” W. 39-7/16” (100.2 cm) 48” W. 45-7/...
Page 13 - Built-In Wall Custom Ventilator
25 1-1/2” (3.81 cm) 1” (2.54 cm) 21-5/16” (54.1 cm) 21-7/8” (55.8 cm) 6” (15.2 cm) 41 o 17-1/4” (43.8 cm) 7/8” (2.2 cm) 1-1/2” (3.8 cm) 17-1/4” (43.8 cm) 11-1/2” (29.2 cm) 21-5/16” (54.1 cm) 6” (15.2 cm) 21-7/8” (55.8 cm) 41 o 9/16” (1.4 cm) D 10” (25.4 cm) dia. duct location 5-1/2” (14.0 cm) D 9/16...
Page 15 - Installation
29 CAUTION: If not using a duct cover, using screws provided, make sure top mounting screws are secured into soffit or cabinet framing. Use additional mounting screws, if necessary. Connect black to black, white to white, and the green/bare wire under the green screw. NOTE: Housing wiring must be pr...
Page 18 - Duct Cover Option
35 3 4 2 Place duct cover top inside duct cover base and lower until desired height is found. Mark height. Use the retaining nuts and bolts to fasten in place and remove tape. Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. 1 2 Measure distance from...
Page 19 - To install ventillation kit
37 4 5/16” nut driver Attach canopy to duct cover/soffit. Seal top of hood to duct with aluminum tape. 3 To install ventillation kit refer to ventillation kit installation instructions. Run duct work down to bottom edge of duct cover/soffit and secure in place. Make sure the duct does not stick down...
Page 20 - Service & Registration
38 39 If service is required, call your dealer or authorized service agency. The name of the authorized service agency can be obtained from the dealer or distributor inyour area. Have the following information readily available. • Model number• Serial number• Date purchased• Name of dealer from whom...